Check identifier 55202 — Correction list LF-AACL
Check identifier 55202 · EDIFACT message type UTILMD · format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55202 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0500070 | Clearing list | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 15700120 | Validity, start date | — | X | — |
238000130 | Date or time or time span, value | — | X | — |
2379 61000140 | CCYYMM | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00150 | Document-/message sender or sender | — | X | — |
303900160 | MP-ID | — | X | — |
3055 900170 | GS1 | — | X | — |
3055 29300180 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00190 | Information contact | — | X | — |
341200200 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800210 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00220 | Electronic mail | — | X | [1P0..1] |
3155 FX00230 | Fax number | — | X | [1P0..1] |
3155 TE00240 | Telephone | — | X | [1P0..1] |
3155 AJ00250 | further telephone | — | X | [1P0..1] |
3155 AL00260 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00270 | Message recipient | — | X | — |
303900280 | MP-ID | — | X | [280] |
3055 900290 | GS1 | — | X | — |
3055 29300300 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | [564] |
7495 Z0100310 | List | — | X | — |
740200320 | List number | — | X | — |
| SG4.STS | — | — | Must | [238] ∧ [249] |
9015 E0100330 | Status of the response | — | X | — |
901300340 | Code of the check step | — | X | — |
1131 E_009600350 | EBD no. E_0096 | — | X | — |
1131 E_009700360 | EBD no. E_0097 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500370 | MaBiS metering point | — | X | — |
322500380 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300390 | Check identifier | — | X | — |
1154 5520200400 | Redispatch / correction list LF-AACL | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00410 | Transaction reference number | — | X | — |
115400420 | Reference, identification | — | X | [632] |
| SG8.SEQ | — | — | Must | — |
1229 Z2200430 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AUU00440 | Reference to a time series | — | X | — |
115400450 | Version of the time series | — | X | — |
| SG4.IDE | — | — | Must | [565] |
7495 2400460 | Transaction | — | X | — |
740200470 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100480 | Status of the response | — | X | — |
901300490 | Code of the check step | — | X | — |
1131 E_009600500 | EBD no. E_0096 | — | X | — |
1131 E_009700510 | EBD no. E_0097 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1600520 | Market location | — | X | — |
322500530 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2100540 | Tranche | — | X | — |
322500550 | ID of the tranche | — | X | [950] |
| SG6.RFF | — | — | Must | — |
1153 TN00560 | Transaction reference number | — | X | — |
115400570 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0100580 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800590 | Market location | — | X | — |
115400600 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z3200610 | Actually balanced curtailed energy | — | X | — |
606000620 | Quantity specification | — | X | [910] |
6411 KWH00630 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900640 | Balancing group | — | X | — |
703700650 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2000660 | Balancing area | — | X | — |
703700670 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500680 | Structure | — | X | — |
7037 Z2100690 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100700 | Code of the time series type | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1500710 | Data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2000720 | Tranche | — | X | — |
115400730 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z0700740 | Actually balanced energy quantity | — | X | — |
606000750 | Quantity specification | — | X | [902] |
6411 KWH00760 | Kilowatt hour | — | X | — |
| UNT | — | — | Must | — |
007400770 | Number of segments in a message | — | X | — |
006200780 | Message reference number | — | X | — |
Conditions of this table
The free text of the 18 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [238] | If SG4 IDE+24 (transaction) is not present |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| [280] | Only MP-ID from the electricity division |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [632] | Note: The list number from the supplier outage energy clearing list must be used |
| [902] | Format: Possible value: ≥ 0 |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and NB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Exchange of the supplier substitute energy clearing list | MaBiS | Electricity | Step 2 |
| NB | NB | Exchange of the supplier substitute energy clearing list | MaBiS | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Correction list LF-AACL |
| AHB | UTILMD AHB electricity |
| Decision tree | E_0097 · E_0096 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Exchange of the supplier substitute energy clearing list | LF → NB | Response message on the LF-AACL |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 109 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.