Check identifier 55168 — Commitment request / demand
Check identifier 55168 · EDIFACT message type UTILMD · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 55168 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] | — | object[] | May | — |
| abwicklungsmodell 00010 | Processing model | Enum Abwicklungsmodell | Must | — |
MODELL_1_BILANZIERUNG_AN_MARKTLOKATION | — | — | Must | — |
MODELL_2_BILANZIERUNG_IM_BILANZIERUNGSGEBIET | — | — | Must | — |
| aggregationsverantwortung 00020 | Aggregation responsibility | Enum Aggregationsverantwortung | X | — |
UENB | — | — | X | — |
VNB | — | — | X | — |
| detailsPrognosegrundlage 00030 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| marktlokationsId 00040 | Which market location these balancing data apply to | string | X | — |
| prognosegrundlage 00050 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00080 | Designation of the profile | string | Must | — |
| einspeisung 00090 | Feed-in indicator | boolean | Must | — |
| profilart 00100 | Profile category | Enum Profilart | Must | — |
ART_STANDARDLASTPROFIL | — | — | Must | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | Must | — |
ART_LASTPROFIL | — | — | Must | — |
| referenzprofilbezeichnung 00110 | Designation of the reference profile | string | Must | — |
| verfahren 00120 | Profiling method | Enum Profilverfahren | Must | — |
SYNTHETISCH | — | — | Must | — |
ANALYTISCH | — | — | Must | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00130 | dienstanbieter | string | Must | — |
| herausgeber 00140 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00150 | klimazone | string | Must | — |
| temperaturmessstelle 00160 | temperaturmessstelle | string | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00170 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00180 | Value | number (float) | Must | — |
| ENERGIELIEFERVERTRAG [ ] | — | object[] | May | — |
| lokationsId 00190 | lokationsId | string | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00200 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 00210 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00220 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00230 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00240 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00250 | House number and supplement | string | X | — |
| landescode 00260 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00270 | City | string | X | — |
| ortsteil 00280 | District | string | X | — |
| postfach 00290 | PO box | string | X | — |
| postleitzahl 00300 | Postal code | string | X | — |
| strasse 00310 | Street | string | X | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00320 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 00330 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 00340 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00350 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00360 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00370 | name4 | string | X | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00380 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00390 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00400 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00410 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00420 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00430 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00440 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00450 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00460 | lokationsbuendelNummer | integer | X | — |
| objectcode 00470 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| energierichtung 00480 | Indicates whether energy is fed in or drawn (fed out). | Enum Energierichtung | X | — |
AUSSP | — | — | X | — |
EINSP | — | — | X | — |
| konfigurationsprodukt 00490 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00500 | Code of the assigned power curve definition for the object | string | X | — |
| marktlokationsId * 00510 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00520 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00530 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| produktdatenRelevanteRolle 00540 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00550 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00560 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00570 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00580 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00590 | weiterverpflichtet | boolean | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00600 | messprodukt | string | X | — |
| obisKennzahl 00610 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 00620 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| verwendungszwecke [ ] | — | object[] | May | — |
| marktrolle 00630 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| zweck 00640 | zweck | array | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00650 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00660 | Metering time period definition | string | X | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| betriebszustand 00670 | Operating state | Enum Betriebszustand | X | — |
GESPERRT_NICHT_ENTSPERREN | — | — | X | — |
GESPERRT | — | — | X | — |
REGELBETRIEB | — | — | X | — |
AUSSERHALB_REGELBETRIEB | — | — | X | — |
| datenqualitaet 00680 | Data quality | Enum Datenqualitaet | X | — |
ERWARTETE_DATEN | — | — | X | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
INFORMATIVE_DATEN | — | — | X | — |
GUELTIGE_DATEN | — | — | X | — |
KEINE_DATEN | — | — | X | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | X | — |
KEINE_DATEN_ERWARTET | — | — | X | — |
DIFFERENZ_DATEN | — | — | X | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | X | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
| messlokationsId * 00690 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00700 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| referenzMarktlokationsId 00710 | referenzMarktlokationsId | string | X | — |
| verwendungsumfang 00720 | Scope of use | Enum Verwendungsumfang | X | — |
MESSLOKATION_PROZESSUAL_BEHANDELT | — | — | X | — |
MESSLOKATION_LOKATIONSBUENDEL | — | — | X | — |
| ablesekartenempfaenger * | — | object | Must | — |
| anrede 00730 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00740 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00750 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00760 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00770 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00780 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00790 | House number and supplement | string | X | — |
| landescode 00800 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00810 | City | string | X | — |
| ortsteil 00820 | District | string | X | — |
| postfach 00830 | PO box | string | X | — |
| postleitzahl 00840 | Postal code | string | X | — |
| strasse 00850 | Street | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00860 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00870 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00880 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00890 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00900 | House number and supplement | string | X | — |
| landescode 00910 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00920 | City | string | X | — |
| ortsteil 00930 | District | string | X | — |
| postfach 00940 | PO box | string | X | — |
| postleitzahl 00950 | Postal code | string | X | — |
| strasse 00960 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00970 | Address supplement 1 | string | X | — |
| zusatz2 00980 | Address supplement 2 | string | X | — |
| zusatz3 00990 | Address supplement 3 | string | X | — |
| zusatz4 01000 | Address supplement 4 | string | X | — |
| zusatz5 01010 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01020 | messprodukt | string | X | — |
| notwendigkeitZweiteMessung 01030 | Necessity of second measurement | Enum NotwendigkeitZweiteMessung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| werteuebermittlungVerwendungszweck 01040 | Purpose of use for value transmission | Enum WerteuebermittlungVerwendungszweck | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| zaehlzeiten | — | object | May | — |
| zaehlzeitDefinition 01050 | Metering time period definition | string | Must | — |
| MESSSTELLENBETRIEBSVERTRAG [ ] * | — | object[] | Must | — |
| lokationsId * 01060 | lokationsId | string | X | — |
| lokationsTyp * 01070 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | X | — |
MALO | — | — | X | — |
MELO | — | — | X | — |
NELO | — | — | X | — |
TECHNISCHE_RESSOURCE | — | — | X | — |
STEUERBARE_RESSOURCE | — | — | X | — |
TRANCHE | — | — | X | — |
MABIS_ZAEHLPUNKT | — | — | X | — |
| korrespondenzpartner * | — | object | Must | — |
| anrede 01080 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 * 01090 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01100 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01110 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01120 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 01130 | House number and supplement | string | X | — |
| landescode 01140 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 01150 | City | string | X | — |
| ortsteil 01160 | District | string | X | — |
| postfach 01170 | PO box | string | X | — |
| postleitzahl 01180 | Postal code | string | X | — |
| strasse 01190 | Street | string | X | — |
| vertragskonditionen | — | object | May | — |
| geplanteTurnusablesung | — | object | May | — |
| ableseZeitraum 01200 | ableseZeitraum | string | X | — |
| vertragspartner2 [ ] * | — | object[] | Must | — |
| anrede 01210 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 01220 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 * 01230 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01240 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01250 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01260 | name4 | string | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 01270 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 01280 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 01290 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| produktdatenRelevanteRolle 01300 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| steuerkanal 01310 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01320 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01330 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01340 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01350 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01360 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| obisKennzahl 01370 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszwecke [ ] | — | object[] | May | — |
| marktrolle 01380 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| zweck 01390 | zweck | array | Must | — |
| NETZNUTZUNGSVERTRAG [ ] | — | object[] | May | — |
| lokationsId 01400 | lokationsId | string | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 01410 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 01420 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01430 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01440 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01450 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 01460 | House number and supplement | string | X | — |
| landescode 01470 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 01480 | City | string | X | — |
| ortsteil 01490 | District | string | X | — |
| postfach 01500 | PO box | string | X | — |
| postleitzahl 01510 | Postal code | string | X | — |
| strasse 01520 | Street | string | X | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 01530 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 01540 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 01550 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01560 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01570 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01580 | name4 | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| konfigurationsprodukt 01590 | konfigurationsprodukt | string | X | — |
| produktdatenRelevanteRolle 01600 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| ressourcenId 01610 | ressourcenId | string | X | — |
| steuerkanal 01620 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01630 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01640 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01650 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01660 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01670 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 01680 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 01690 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 01700 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 01710 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| enwg 01720 | enwg | boolean | Must | — |
| erzeugungsart 01730 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| referenzMarktlokation 01740 | referenzMarktlokation | string | X | — |
| referenzMesslokation 01750 | referenzMesslokation | string | X | — |
| referenzNetzlokation 01760 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 01770 | referenzSteuerbareRessource | string | X | — |
| ressourcenId 01780 | ressourcenId | string | X | — |
| speicherart 01790 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 01800 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 01810 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | — |
| waermenutzung 01820 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| weitereEinrichtung 01830 | weitereEinrichtung | boolean | Must | — |
| nennleistung | — | object | May | — |
| abgabe 01840 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 01850 | Recording of the rated power | number (float) | X | — |
| TRANCHE [ ] | — | object[] | May | — |
| bildungTranchengroesse 01860 | BildungTranchengroesse | Enum BildungTranchengroesse | X | — |
PROZENTUAL | — | — | X | — |
AUFTEILUNGSFAKTOR | — | — | X | — |
AUFTEILUNG_TECHNISCHE_RESSOURCEN | — | — | X | — |
BERECHNUNGSFORMEL | — | — | X | — |
| referenzMarktlokationsId 01870 | referenzMarktlokationsId | string | X | — |
| tranchenId 01880 | tranchenId | string | X | — |
| aufteilungsmenge | — | object | May | — |
| einheit 01890 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 01900 | Value | number (float) | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01910 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 01920 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01930 | messprodukt | string | X | — |
| verwendungszwecke [ ] | — | object[] | May | — |
| marktrolle 01940 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| zweck 01950 | zweck | array | Must | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 01960 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| fernschaltung 01970 | Remote switching | Enum Fernschaltung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| gateway 01980 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| marktlokationsId 01990 | marktlokationsId | string | X | — |
| messlokationsId 02000 | messlokationsId | string | X | — |
| messwerterfassung 02010 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| tarifart 02020 | Specification regarding supported tariff types. | Enum Tarifart | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
SMART_METER | — | — | Must | — |
LEISTUNGSGEMESSEN | — | — | Must | — |
| zaehlerauspraegung 02030 | Specification regarding the direction of the meter. | Enum Zaehlerauspraegung | Must | — |
EINRICHTUNGSZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
| zaehlernummer 02040 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 02050 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 02060 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 02070 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraetetyp 02080 | List of possible billable device types | Enum Geraetetyp | X | — |
WECHSELSTROMZAEHLER | — | — | X | — |
DREHSTROMZAEHLER | — | — | X | — |
ZWEIRICHTUNGSZAEHLER | — | — | X | — |
RLM_ZAEHLER | — | — | X | — |
IMS_ZAEHLER | — | — | X | — |
BALGENGASZAEHLER | — | — | X | — |
MAXIMUMZAEHLER | — | — | X | — |
MULTIPLEXANLAGE | — | — | X | — |
PAUSCHALANLAGE | — | — | X | — |
VERSTAERKERANLAGE | — | — | X | — |
SUMMATIONSGERAET | — | — | X | — |
IMPULSGEBER | — | — | X | — |
EDL_21_ZAEHLERAUFSATZ | — | — | X | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | X | — |
MENGENUMWERTER | — | — | X | — |
STROMWANDLER | — | — | X | — |
SPANNUNGSWANDLER | — | — | X | — |
DATENLOGGER | — | — | X | — |
KOMMUNIKATIONSANSCHLUSS | — | — | X | — |
MODEM | — | — | X | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
DREHKOLBENGASZAEHLER | — | — | X | — |
TURBINENRADGASZAEHLER | — | — | X | — |
ULTRASCHALLZAEHLER | — | — | X | — |
WIRBELGASZAEHLER | — | — | X | — |
MODERNE_MESSEINRICHTUNG | — | — | X | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | X | — |
STEUEREINRICHTUNG | — | — | X | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | X | — |
TARIFSCHALTGERAET | — | — | X | — |
RUNDSTEUEREMPFAENGER | — | — | X | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | X | — |
MESSWANDLERSATZ_IMS_MME | — | — | X | — |
KOMBIMESSWANDLER_IMS_MME | — | — | X | — |
TARIFSCHALTGERAET_IMS_MME | — | — | X | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | X | — |
TEMPERATUR_KOMPENSATION | — | — | X | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | X | — |
SONSTIGES_GERAET | — | — | X | — |
SMARTMETERGATEWAY | — | — | X | — |
STEUERBOX | — | — | X | — |
BLOCKSTROMWANDLER | — | — | X | — |
KOMBIMESSWANDLER | — | — | X | — |
MODEM_GSM | — | — | X | — |
ETHERNET_KOM | — | — | X | — |
PLC_COM | — | — | X | — |
MODEM_FESTNETZ | — | — | X | — |
DSL_KOM | — | — | X | — |
LTE_KOM | — | — | X | — |
DICHTEMENGENUMWERTER | — | — | X | — |
TEMPERATURMENGENUMWERTER | — | — | X | — |
ZUSTANDSMENGENUMWERTER | — | — | X | — |
MESSDATENREGISTRIERGERAET | — | — | X | — |
WANDLER | — | — | X | — |
BEFESTIGUNGSEINRICHTUNG | — | — | X | — |
| weitereGeraetenummern 02090 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 02100 | faktor | number (float) | Must | — |
| geraetemerkmal 02110 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 02120 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| konfiguration 02130 | Configuration (iMSys) of the meter register | string | X | — |
| nachkommastelle 02140 | nachkommastelle | integer | Must | — |
| obisKennzahl 02150 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 02160 | vorkommastelle | integer | Must | — |
| wertegranularitaet 02170 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| datumleistungsbeginn * 02180 | Date of the planned start of service / DTM+76 | string (date-time) | X | — |
| dokumentennummer * 02190 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 02200 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 02210 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 02220 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 02230 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 02240 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 02250 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 02260 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02270 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 02280 | Email address | string | Must | — |
| nachname 02290 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 02300 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 02310 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 02320 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02330 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55168 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | [637] |
1001 Z4000080 | Request | — | X | [638] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document-/message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00130 | Document-/message sender or sender | — | X | — |
303900140 | MP-ID | — | X | — |
3055 900150 | GS1 | — | X | — |
3055 29300160 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00170 | Information contact | — | X | — |
341200180 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800190 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00200 | Electronic mail | — | X | [1P0..1] |
3155 FX00210 | Fax number | — | X | [1P0..1] |
3155 TE00220 | Telephone | — | X | [1P0..1] |
3155 AJ00230 | further telephone | — | X | [1P0..1] |
3155 AL00240 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00250 | Message recipient | — | X | — |
303900260 | MP-ID | — | X | — |
3055 900270 | GS1 | — | X | — |
3055 29300280 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400290 | Transaction | — | X | — |
740200300 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 7600310 | Delivery date/time, scheduled | — | X | — |
238000320 | Date or time or time span, value | — | X | [UB1] |
2379 30300330 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700340 | Transaction reason | — | X | — |
9013 E0100350 | Move-in/move-out (relocation) | — | X | — |
9013 E0200360 | Move-in to creation | — | X | — |
9013 E0300370 | Change | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800380 | Grid location | — | X | — |
322500390 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600400 | Market location | — | X | — |
322500410 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2200420 | Dormant market location | — | X | — |
322500430 | ID of the dormant market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000440 | Technical resource | — | X | — |
322500450 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900460 | Controllable resource | — | X | — |
322500470 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z2100480 | Tranche | — | X | — |
322500490 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700500 | Metering location | — | X | — |
322500510 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300520 | Check identifier | — | X | — |
1154 5516800530 | WiM electricity / commitment request / demand | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z5000540 | Scheduling data of the market location | — | X | — |
115400550 | ID of the market location / reference to time period ID | — | X | [950] |
| SG6.DTM | — | — | Must | [86] ∧ [78] ∧ [271] ∧ [618] |
2005 75200560 | Periodic meter reading | — | X | — |
238000570 | Date or time or time span, value | — | X | — |
2379 10400580 | MMWW-MMWW | — | X | — |
2379 10600590 | MMDD | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z7800600 | Reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100610 | Location bundle structure | — | X | — |
1153 Z3900620 | No standardized location bundle structure available | — | X | — |
115400630 | ID of the location bundle structure | — | X | [333] |
115600640 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 Z5800650 | Assignment of the location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200660 | Grid location | — | X | — |
1153 Z1800670 | Market location | — | X | — |
1153 Z1900680 | Metering location | — | X | — |
1153 Z3700690 | Technical resource | — | X | — |
115400700 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2312] |
1153 Z3300710 | Object code of the location in the location bundle structure | — | X | — |
115400720 | Object code | — | X | — |
115600730 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400740 | upstream metering location | — | X | — |
1153 Z3500750 | upstream grid location | — | X | — |
115400760 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600770 | assigned market location | — | X | — |
115400780 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 Z5100790 | Data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200800 | Grid location | — | X | — |
115400810 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900820 | Control channel | — | X | — |
7037 ZF200830 | No control channel available | — | X | — |
7037 ZF300840 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300850 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100860 | MSB | — | X | — |
113100870 | MP-ID | — | X | — |
7110 Z3900880 | Default metering point operator | — | X | — |
7110 Z4000890 | Competitive metering point operator | — | X | — |
7110 Z4100900 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5700910 | OBIS data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200920 | Grid location | — | X | — |
115400930 | ID of the grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 500940 | Product identification | — | X | — |
714000950 | OBIS code of the grid location | — | X | — |
7143 SRW00960 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA800970 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD100980 | Reactive energy billing / operational management | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA700990 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z4701000 | End customer billing | — | X | [1P1..1] |
7111 ZD101010 | Reactive energy billing / operational management | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z6001020 | Product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3201030 | Grid location | — | X | — |
115401040 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 501050 | Product identification | — | X | — |
714001060 | Configuration product code | — | X | [412] |
7143 Z1201070 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5301080 | Code of the power curve definition | — | X | — |
703701090 | Code of the power curve definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301100 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8801110 | NB | — | X | — |
7111 Z8901120 | LF | — | X | — |
113101130 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA701140 | LF | — | X | [1P0..1] |
7037 ZA801150 | NB | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0101160 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801170 | Market location | — | X | — |
115401180 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 26501190 | Estimated annual quantity total/annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0801200 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606001210 | Quantity | — | X | [902] |
6411 Z1601220 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH01230 | Kilowatt hour | — | X | [104] |
| SG9.QTY | — | — | Must | — |
6063 3101240 | Estimated annual quantity total | — | X | — |
606001250 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH01260 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3001270 | Delivery direction | — | X | — |
7037 Z0601280 | Generation | — | X | — |
7037 Z0701290 | Consumption | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301300 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | [78] ∧ [221] |
7111 Z8901310 | LF | — | X | — |
113101320 | MP-ID | — | X | [611] |
| SG10.CAV | — | — | Must | — |
7111 Z9001330 | ÜNB | — | X | — |
113101340 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101350 | MSB | — | X | — |
113101360 | MP-ID | — | X | [621] |
7110 Z3901370 | Default metering point operator | — | X | — |
7110 Z4001380 | Competitive metering point operator | — | X | — |
7110 Z4101390 | Fallback metering point operator | — | X | — |
7110 Z1901400 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001410 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301420 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301430 | Extra-high voltage | — | X | — |
7111 E0401440 | High voltage | — | X | — |
7111 E0501450 | Medium voltage | — | X | — |
7111 E0601460 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301470 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201480 | iMS | — | X | — |
7111 Z5301490 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 601500 | Responsible party | — | X | — |
7037 ZA801510 | NB | — | X | — |
7037 ZA901520 | ÜNB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001530 | Forecast based on values | — | X | — |
7037 ZA601540 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [210] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0201550 | SLP/SEP | — | X | [1P0..1] |
7111 E1401560 | TLP/TEP | — | X | [1P0..1] |
7111 Z3601570 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3401580 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3301590 | EEG market location without DV obligation | — | X | — |
7111 Z3401600 | KWKG market location without DV obligation | — | X | — |
7111 Z3501610 | other market location | — | X | — |
7111 Z3701620 | EEG market location with DV obligation | — | X | — |
7111 Z4601630 | KWKG market location with DV obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 ZA201640 | Processing model | — | X | — |
7037 ZE901650 | Model 1 "Balancing at the market location" | — | X | — |
7037 ZF001660 | Model 2 "Balancing in the balancing area (BG) of the LPB" | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2701670 | Required metering product of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801680 | Market location | — | X | — |
115401690 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501700 | Product identification | — | X | — |
714001710 | Metering product code | — | X | [425] |
7143 Z1101720 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901730 | Code of the metering time period definition | — | X | — |
7059 Z4101740 | No metering time period required for metering product | — | X | [417] |
703701750 | Code of the metering time period definition | — | X | [438] |
| SG10.CCI | — | — | Must | — |
7037 ZA801760 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401770 | Grid usage settlement | — | X | [19P1..1] ⊻ [20P1..1] ⊻ [22P1..1] ⊻ [26P1..1] |
7111 Z8501780 | Balancing group settlement | — | X | [21P0..1] ⊻ [22P0..1] ⊻ [23P0..1] ⊻ [24P0..1] |
7111 Z8601790 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z9201800 | Transmission to the HKNR | — | X | [23P1..1] ⊻ [24P1..1] |
7111 ZE101810 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA701820 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401830 | Grid usage settlement | — | X | [19P0..1] ⊻ [20P0..1] ⊻ [22P0..1] ⊻ [26P0..1] |
7111 Z8501840 | Balancing group settlement | — | X | [21P1..1] ⊻ [22P1..1] ⊻ [23P1..1] ⊻ [24P1..1] |
7111 Z8601850 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z4701860 | End customer billing | — | X | [19P1..1] ⊻ [20P0..1] ⊻ [22P1..1] ⊻ [24P1..1] ⊻ [25P1..1] ⊻ [26P0..1] ⊻ [27P1..1] |
7111 ZE101870 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA901880 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8501890 | Balancing group settlement | — | X | [1P0..1] |
7111 ZB501900 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0201910 | OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801920 | Market location | — | X | — |
115401930 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501940 | Product identification | — | X | — |
714001950 | OBIS code of the market location | — | X | [314] |
7143 SRW01960 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401970 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901980 | Annually | — | X | — |
7111 ZE801990 | Semi-annual | — | X | — |
7111 ZE902000 | Quarterly | — | X | — |
7111 ZB702010 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3902020 | Code of the metering time period definition | — | X | — |
703702030 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3802040 | Code of the metering time period register | — | X | — |
703702050 | Code of the metering time period register | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA802060 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8402070 | Grid usage settlement | — | X | [29P1..1] ⊻ [30P1..1] ⊻ [32P1..1] ⊻ [36P1..1] |
7111 Z8502080 | Balancing group settlement | — | X | [31P0..1] ⊻ [32P0..1] ⊻ [33P0..1] ⊻ [34P0..1] |
7111 Z8602090 | Excess/shortfall quantity settlement | — | X | [30P1..1] ⊻ [37P1..1] |
7111 Z9202100 | Transmission to the HKNR | — | X | [33P1..1] ⊻ [34P1..1] |
7111 ZE102110 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA702120 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8402130 | Grid usage settlement | — | X | [29P0..1] ⊻ [30P0..1] ⊻ [32P0..1] ⊻ [36P0..1] |
7111 Z8502140 | Balancing group settlement | — | X | [31P1..1] ⊻ [32P1..1] ⊻ [33P1..1] ⊻ [34P1..1] |
7111 Z8602150 | Excess/shortfall quantity settlement | — | X | [30P1..1] ⊻ [37P1..1] |
7111 Z4702160 | End customer billing | — | X | [28P0..1] ⊻ [29P1..1] ⊻ [30P0..1] ⊻ [32P1..1] ⊻ [34P1..1] ⊻ [35P1..1] ⊻ [36P0..1] ⊻ [37P1..1] |
7111 ZE102170 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA902180 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502190 | Balancing group settlement | — | X | [1P0..1] |
7111 ZB502200 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z5902210 | Product data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1802220 | Market location | — | X | — |
115402230 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 502240 | Product identification | — | X | — |
714002250 | Product/service number | — | X | — |
7143 Z1202260 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5302270 | Code of the power curve definition | — | X | — |
703702280 | Code of the definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA802290 | NB | — | X | [1P0..1] |
7037 ZA702300 | LF | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z1502310 | Data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002320 | Tranche | — | X | — |
115402330 | ID of the tranche | — | X | [950] |
| SG8.RFF | — | — | Must | — |
1153 Z1602340 | assigned market location | — | X | — |
115402350 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 1102360 | Distribution quantity | — | X | — |
606002370 | Quantity specification in % | — | X | [914] ∧ [930] ∧ [955] |
6411 P102380 | Percent | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302390 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8902400 | LF | — | X | — |
113102410 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3702420 | Basis for determining the tranche size | — | X | — |
7037 ZD102430 | Percentage-based | — | X | — |
7037 ZD202440 | Distribution factor based on reference carrier/installed capacity | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1602450 | Required product of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002460 | Tranche | — | X | — |
115402470 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 502480 | Product identification | — | X | — |
714002490 | Metering product code | — | X | [426] |
7143 Z1102500 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA802510 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502520 | Balancing group settlement | — | X | [1P0..1] |
7111 Z9202530 | Transmission to the HKNR | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA702540 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502550 | Balancing group settlement | — | X | [1P1..1] |
7111 Z4702560 | End customer billing | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA902570 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502580 | Balancing group settlement | — | X | [1P0..1] |
7111 ZB502590 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z5202600 | Data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3702610 | Technical resource | — | X | — |
115402620 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [668] |
1153 Z3402630 | upstream metering location | — | X | — |
115402640 | ID of a location | — | X | [951] |
| SG8.RFF | — | — | Must | [668] |
1153 Z1602650 | assigned market location | — | X | — |
115402660 | ID of the market location | — | X | [950] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3802670 | Controllable resource | — | X | — |
115402680 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3202690 | Grid location | — | X | — |
115402700 | ID of the grid location | — | X | [960] |
| SG9.QTY | — | — | Must | — |
6063 Z4302710 | Rated power (input) | — | X | — |
606002720 | Quantity | — | X | — |
6411 KWT02730 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4402740 | Rated power (output) | — | X | — |
606002750 | Quantity | — | X | — |
6411 KWT02760 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4202770 | Storage capacity | — | X | — |
606002780 | Quantity | — | X | — |
6411 KWH02790 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1702800 | Type of electricity consumption | — | X | — |
7059 Z5002810 | Type of electricity generation | — | X | — |
7059 Z5602820 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6402830 | Power/light | — | X | [1P0..1] |
7111 Z6502840 | Heat/cold | — | X | [1P0..1] |
7111 ZE502850 | E-mobility | — | X | [1P0..1] |
7111 ZA802860 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5602870 | Storage heating | — | X | — |
7111 Z5702880 | Heat pump (unspecified) | — | X | — |
7111 Z6102890 | Direct heating | — | X | — |
7111 ZV502900 | Heat pump (heat and cold) | — | X | — |
7111 ZV602910 | Heat pump (cold) | — | X | — |
7111 ZV702920 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE602930 | Wallbox | — | X | — |
7111 Z8702940 | E-mobility charging station | — | X | — |
7111 ZE702950 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF502960 | Solar | — | X | — |
7111 ZF602970 | Wind | — | X | — |
7111 ZG002980 | Gas | — | X | — |
7111 ZG102990 | Water | — | X | — |
7111 ZG503000 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF703010 | Hydrogen storage | — | X | — |
7111 ZF803020 | Pumped storage | — | X | — |
7111 ZF903030 | Battery storage | — | X | — |
7111 ZG603040 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG803050 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG903060 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z6303070 | Information on further technical equipment | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZH703080 | Further technical equipment present | — | X | — |
7111 ZH803090 | No further technical device available | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6203100 | Data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3803110 | Controllable resource | — | X | — |
115403120 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4903130 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF203140 | Service description of the control channel | — | X | — |
1131 Z1403150 | On/Off | — | X | — |
1131 Z1503160 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB303170 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9103180 | MSB | — | X | — |
113103190 | MP-ID | — | X | — |
7110 Z3903200 | Default metering point operator | — | X | — |
7110 Z4003210 | Competitive metering point operator | — | X | — |
7110 Z4103220 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6103230 | Product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3803240 | Controllable resource | — | X | — |
115403250 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | — |
4347 503260 | Product identification | — | X | — |
714003270 | Configuration product code | — | X | — |
7143 Z1203280 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5203290 | Code of the switching time definition | — | X | — |
7059 Z5303300 | Code of the power curve definition | — | X | — |
703703310 | Code of the definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB303320 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803330 | NB | — | X | — |
7111 Z8903340 | LF | — | X | — |
113103350 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA803360 | NB | — | X | [1P0..1] |
7037 ZA703370 | LF | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z1803380 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903390 | Metering location | — | X | — |
115403400 | ID of the metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [668] |
1153 Z1603410 | assigned market location | — | X | — |
115403420 | ID of the market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 ZB303430 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9103440 | MSB | — | X | — |
113103450 | MP-ID | — | X | [621] |
7110 Z3903460 | Default metering point operator | — | X | — |
7110 Z4003470 | Competitive metering point operator | — | X | — |
7110 Z4103480 | Fallback metering point operator | — | X | — |
7110 Z1903490 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2003500 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF003510 | gMSB | — | X | — |
113103520 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | [184] |
7111 ZB403530 | MSBA | — | X | — |
113103540 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0403550 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0303560 | Extra-high voltage | — | X | — |
7111 E0403570 | High voltage | — | X | — |
7111 E0503580 | Medium voltage | — | X | — |
7111 E0603590 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0103600 | Scope of use | — | X | — |
7037 Z8203610 | ID of the metering location handled in the process | — | X | [2236] |
7037 Z8103620 | ID of the metering location in the location bundle | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3203630 | Operating state of the metering location | — | X | — |
7037 ZC103640 | Metering location blocked and may not be unblocked | — | X | — |
7037 ZC203650 | Metering location blocked and may be unblocked | — | X | — |
7037 ZC303660 | Metering location in regular operation | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1903670 | Required product of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903680 | Metering location | — | X | — |
115403690 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [429] |
1153 Z1803700 | Market location | — | X | — |
115403710 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 503720 | Product identification | — | X | — |
714003730 | Metering product code | — | X | [427] |
7143 Z1103740 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3503750 | Description required value | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZC903760 | Second measurement required for comparative measurement | — | X | — |
7110 Z0603770 | present | — | X | — |
7110 Z0703780 | not present | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803790 | NB | — | X | — |
7110 Z0603800 | present | — | X | — |
7110 Z0703810 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3903820 | Code of the metering time period definition | — | X | — |
7059 Z4103830 | No metering time period required for metering product | — | X | [417] |
703703840 | Code of the metering time period definition | — | X | [438] |
| SG8.SEQ | — | — | Must | — |
1229 Z0303850 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903860 | Metering location | — | X | — |
115403870 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1403880 | Smart meter gateway | — | X | — |
115403890 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1303900 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ03910 | analog household meter (three-phase current) | — | X | — |
7111 WSZ03920 | analog alternating current meter | — | X | — |
7111 LAZ03930 | Load curve meter | — | X | — |
7111 MAZ03940 | Maximum demand meter | — | X | — |
7111 MME03950 | modern metering device according to MsbG | — | X | — |
7111 EHZ03960 | electronic household meter | — | X | — |
7111 IVA03970 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0103980 | EDL40 | — | X | [136] |
7110 Z0203990 | EDL21 | — | X | [136] |
7110 Z0304000 | other EHZ | — | X | [136] |
7110 Z0404010 | Standard | — | X | [346] |
7110 Z0504020 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3004030 | Device number | — | X | — |
711004040 | Device number | — | X | — |
| SG10.CAV | — | — | Must | [139] |
7111 ETZ04050 | Single tariff | — | X | — |
7111 ZTZ04060 | Two-tariff | — | X | — |
7111 NTZ04070 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ERZ04080 | Single-direction meter | — | X | — |
7111 ZRZ04090 | Bidirectional meter | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5804100 | Remote switching of the metering device | — | X | — |
7110 Z0604110 | present | — | X | — |
7110 Z0704120 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2804130 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 BKE04140 | Plug-in technology (mounting and contacting device) | — | X | — |
7111 DPA04150 | 3-Three-point suspension | — | X | — |
7111 HUT04160 | DIN rail | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1204170 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR04180 | remotely readable meters | — | X | — |
7111 MMR04190 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2004200 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [78] ∧ [665] |
1153 MG04210 | Device number of the meter | — | X | [441] |
1153 Z1404220 | Smart meter gateway | — | X | — |
115404230 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [78] |
1153 Z1904240 | Metering location | — | X | — |
115404250 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [78] ∧ [402] ∧ [420] ∧ [651] |
1153 Z1804260 | Market location | — | X | — |
115404270 | ID of a market location | — | X | [950] |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK04280 | Application reference number | — | X | — |
115404290 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 504300 | Product identification | — | X | — |
714004310 | OBIS code of the metering device | — | X | [323] |
7143 SRW04320 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE404330 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD904340 | Annually | — | X | — |
7111 ZE804350 | Semi-annual | — | X | — |
7111 ZE904360 | Quarterly | — | X | — |
7111 ZB704370 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1104380 | Product | — | X | — |
7037 Z3304390 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711004400 | Digits before the decimal point | — | X | — |
711004410 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6304420 | Local identifier for control purposes | — | X | — |
703604430 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0404440 | Instrument transformer data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04450 | Device number of the meter | — | X | — |
115404460 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2504470 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3004480 | Device number | — | X | — |
711004490 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW04500 | Current transformer set | — | X | — |
7111 MPW04510 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW04520 | Block current transformer | — | X | — |
7111 MUW04530 | Voltage transformer set | — | X | — |
711004540 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 Z0504550 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04560 | Device number of the meter | — | X | — |
115404570 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2604580 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004590 | Device number | — | X | — |
711004600 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM04610 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH04620 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC04630 | PLC comm. device | — | X | — |
7111 PST04640 | Landline comm. dev. TAE | — | X | — |
7111 DSL04650 | DSL comm. dev. | — | X | — |
7111 LTE04660 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0604670 | Data of the technical control device | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04680 | Device number of the meter | — | X | — |
115404690 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2704700 | Technical control device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004710 | Device number | — | X | — |
711004720 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 RSU04730 | Ripple control receiver | — | X | — |
7111 TSU04740 | Tariff time switch | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1304750 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7504760 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004770 | Device number | — | X | — |
711004780 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z1404790 | Control box | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1404800 | Smart meter gateway | — | X | — |
115404810 | Identification / number of the smart meter gateway | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804820 | Market location | — | X | — |
115404830 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 Z7604840 | Control box | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004850 | Device number | — | X | — |
711004860 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z2104870 | Profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804880 | Market location | — | X | — |
115404890 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0204900 | Standard load profile | — | X | — |
7059 Z0404910 | Standard feed-in profile | — | X | — |
7037 E0104920 | synthetic method | — | X | — |
7037 Z1004930 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711104940 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0804950 | Profile set data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804960 | Market location | — | X | — |
115404970 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0304980 | day-parameter-dependent load profile | — | X | — |
7059 Z0504990 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0105000 | synthetic method | — | X | — |
7037 Z1005010 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711105020 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9905030 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA005040 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703705050 | ID of climate zone / temperature measuring point | — | X | — |
113105060 | Service provider | — | X | [58] |
3055 8905070 | Assigned by the trader (here grid operator) | — | X | — |
3055 29305080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z3805090 | Reference profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1805100 | Market location | — | X | — |
115405110 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0505120 | day-parameter-dependent feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711105130 | Code of the reference profile | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0905140 | Customer of the LF | — | X | — |
303605150 | Name | — | X | — |
3045 Z0105160 | Structure of person names | — | X | — |
3045 Z0205170 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805180 | Market location | — | X | — |
115405190 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0405200 | Correspondence address of the customer of the LF | — | X | — |
303605210 | Name | — | X | — |
3045 Z0105220 | Structure of person names | — | X | — |
3045 Z0205230 | Structure of the company name | — | X | — |
304205240 | Street and house number or PO box | — | X | — |
316405250 | City | — | X | — |
325105260 | Postal code | — | — | M [268] S [166] |
320705270 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805280 | Market location | — | X | — |
115405290 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0705300 | Customer of the MSB | — | X | — |
303605310 | Name | — | X | — |
3045 Z0105320 | Structure of person names | — | X | — |
3045 Z0205330 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905340 | Metering location | — | X | — |
115405350 | ID of the metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0805360 | Correspondence address of the customer of the MSB | — | X | — |
303605370 | Name | — | X | — |
3045 Z0105380 | Structure of person names | — | X | — |
3045 Z0205390 | Structure of the company name | — | X | — |
304205400 | Street and house number or PO box | — | X | — |
316405410 | City | — | X | — |
325105420 | Postal code | — | — | M [268] S [166] |
320705430 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z2505440 | Customer of the NB | — | X | — |
303605450 | Name | — | X | — |
3045 Z0105460 | Structure of person names | — | X | — |
3045 Z0205470 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805480 | Market location | — | X | — |
115405490 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z2605500 | Correspondence address of the customer of the NB | — | X | — |
303605510 | Name | — | X | — |
3045 Z0105520 | Structure of person names | — | X | — |
3045 Z0205530 | Structure of the company name | — | X | — |
304205540 | Street and house number or PO box | — | X | — |
316405550 | City | — | X | — |
325105560 | Postal code | — | — | M [268] S [166] |
320705570 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805580 | Market location | — | X | — |
115405590 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0305600 | Metering location address | — | X | — |
312405610 | Additional information for identification | — | — | — |
304205620 | Street and house number or PO box | — | — | S [166] M [212] |
316405630 | City | — | X | — |
325105640 | Postal code | — | X | — |
320705650 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905660 | Metering location | — | X | — |
115405670 | ID of a metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0505680 | Name and address for the meter reading card | — | X | — |
303605690 | Name | — | X | — |
3045 Z0105700 | Structure of person names | — | X | — |
3045 Z0205710 | Structure of the company name | — | X | — |
304205720 | Street and house number or PO box | — | X | — |
316405730 | City | — | X | — |
325105740 | Postal code | — | — | M [268] S [166] |
320705750 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905760 | Metering location | — | X | — |
115405770 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007405780 | Number of segments in a message | — | X | — |
006205790 | Message reference number | — | X | — |
Conditions of this table
The free text of the 122 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [78] | If SG4 STS+7++E02 (transaction reason: move-in to creation) is not present |
| [86] | If the RFF+Z50 (dates of the market location) from this SG6 (dates of the market location) references the same SG5 LOC+Z16 (market location) as a RFF+Z18 (market location) from a SG8 SEQ+Z01 (data of the market location) in which the SG10 CCI+++ZA6 (forecast based on profiles) is present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption) CAV+ZE5 (e-mobility) is present |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [139] | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [166] | If present |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) with an identical code in DE1229 |
| [184] | If in the same SG8 SEQ+Z18 (data of the metering location) a CCI+Z01++Z82 (scope of use: ID of the metering location handled in the process) is present |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [221] | If no SG8 SEQ+Z15 (data of the tranche) references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z01 (data of the market location) |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption) is present in the CAV+Z65 (heat/cooling) |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [271] | If the RFF+Z50 (dates of the market location) from this SG6 (dates of the market location) references the same SG5 LOC+Z16 (market location) as a RFF+Z18 (market location) from a SG8 SEQ+Z01 (data of the market location) in which the SG10 CCI+++Z83 (metering classification of the market location) CAV+Z53 (kME/mME) is present |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [417] | If no metering time period is required for the required value |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [425] | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| [426] | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| [427] | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| [429] | If in the same SG8 SEQ+Z19/ZF4 (required metering product of the metering location) the PIA+5 DE7140 is present with a metering product from the code list of configurations chapter 2.3.1 standard metering product of the metering location with the option of assigning a metering time period |
| [438] | If code Z39 (code of the metering time period) is present in DE7059 in the same CCI |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [618] | Note: Previous date of the MSBA. If the MSBN wishes to use a different date, it communicates the new date by means of a master data change |
| [621] | Note: The MSB must be specified that is assigned to the location from the point in time named in DTM+76 (date of the planned start of supply). |
| [637] | Note: In the case of a commitment request |
| [638] | Note: In the event of a request to take over the individual metering location by the gMSB |
| [651] | Note: The market locations for which the OBIS named here is required must be specified |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [668] | Note: This segment will be removed from the UTILMD after completion of the introduction of the location bundle structure as of 01.10.2025 |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2236] | Code once per SG4 IDE+24 (transaction) |
| [2312] | If the object code "9992000001256" (grid location) is not present in DE1154 of the same RFF+Z33, the RFF+Z33 must be specified exactly once in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer) is present, the segment must be specified exactly once |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P1..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [19P1..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [22P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [26P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [22P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [23P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [27P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [23P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [38P1..1] | [419] If no other package in this SG10 in the same SG8 SEQ leads to the possibility of specifying at least one other code in this data element |
| [19P0..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [26P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [25P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present |
| [29P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [410] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [30P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [411] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [32P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [36P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [406] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and highest 1/4 hour in the month in the PIA+5 present |
| [31P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [32P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [33P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [34P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [37P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [411] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [33P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [34P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [29P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [410] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [30P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [411] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [36P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [406] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and highest 1/4 hour in the month in the PIA+5 present |
| [31P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [28P0..1] | [407] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for reactive energy in the PIA+5 present |
| [35P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [410] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9904446000007:500+{{date}}:{{time}}+M3FXU3PV'
UNH+UNHM44RYD60+UTILMD:D:11A:UN:S2.1'
BGM+E01+BGMM42HSI1V'
DTM+137:202604011200?+00:303'
NAD+MS+9900321000005::293'
NAD+MR+9904446000007::293'
IDE+24+123456'
DTM+76:202606302200?+00:303'
STS+7++E03'
LOC+Z18+E1688117482'
LOC+Z16+50074561188'
LOC+Z20+D417MLM8164'
LOC+Z19+C816417ST77'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55168'
RFF+Z50:50074561188'
DTM+752:0101:106'
SEQ+Z78'
RFF+Z31:9992000000026'
SEQ+Z58'
RFF+Z32:E1688117482'
RFF+Z33:9992000001256'
SEQ+Z58'
RFF+Z18:50074561188'
RFF+Z33:9992000001016'
SEQ+Z58'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001032'
SEQ+Z58'
RFF+Z37:D417MLM8164'
RFF+Z33:9992000001024'
SEQ+Z51'
RFF+Z32:E1688117482'
CCI+Z49++ZF3'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+Z57'
RFF+Z32:E1688117482'
PIA+5+1-1?:5.29.0:SRW'
CCI+++ZA8'
CAV+ZD1'
CCI+++ZA7'
CAV+ZD1'
SEQ+Z60'
RFF+Z32:E1688117482'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
CCI+++ZB3'
CAV+Z88:9900321000005'
CCI+++ZA8'
SEQ+Z01'
RFF+Z18:50074561188'
QTY+31:2000:KWH'
CCI+Z30++Z07'
CCI+++ZB3'
CAV+Z89:9903790000002'
CAV+Z90:4045399000077'
CAV+Z91:9904446000007::Z39:Z20'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+6++ZA8'
CCI+++ZA6'
CAV+E02'
CCI+ZA2++ZE9'
SEQ+Z27'
RFF+Z18:50074561188'
PIA+5+9991000000044:Z11'
CCI+Z41'
CCI+++ZA8'
CAV+ZE1'
CCI+++ZA7'
CAV+Z47'
SEQ+Z52'
RFF+Z37:D417MLM8164'
RFF+Z34:DE0032106765712000000000000000037'
RFF+Z16:50074561188'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+Z62'
RFF+Z38:C816417ST77'
CCI+Z49'
CAV+ZF2:Z14'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+Z61'
RFF+Z38:C816417ST77'
PIA+5+9991000000713:Z12'
CCI+Z52++ABC'
CCI+++ZB3'
CAV+Z88:9900321000005'
CCI+++ZA8'
SEQ+Z18'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z16:50074561188'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39:Z20'
CAV+ZF0:9904446000007'
CAV+ZB4:9904446000007'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
CCI+Z32++ZC3'
SEQ+Z19'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z18:50074561188'
PIA+5+9991000000151:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
CCI+Z41'
SEQ+Z03'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::EL001IK01013852469'
CAV+ETZ'
CAV+ERZ'
CAV+Z58:::Z07'
CCI+++Z28'
CAV+BKE'
CCI+++E12'
CAV+MMR'
SEQ+Z20'
RFF+MG:EL001IK01013852469'
RFF+Z19:DE0032106765712000000000000000037'
PIA+5+1-1?:1.8.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::7:3'
SEQ+Z21'
RFF+Z18:50074561188'
CCI+Z02++E01'
CAV+H0'
NAD+Z09+++Mustermann:Max::::Z01'
RFF+Z18:50074561188'
NAD+Z07+++Mustermann:Max::::Z01'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z08+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
NAD+Z03++Mustermann:Max++Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z05+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
UNT+149+UNHM44RYD60'
UNZ+1+M3FXU3PV'[1 item
{6 fields
"data": {3 fields
"stammdaten": {11 fields
"MARKTLOKATION": [1 item
{10 fields
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{3 fields
"verwendungszwecke": [2 items
{2 fields
{2 fields
"zweck": [1 item
"zaehlzeiten": {1 field
"NETZLOKATION": [1 item
{11 fields
"auftraggebenderMarktpartner": {4 fields
"marktrollen": [1 item
{7 fields
"zaehlwerke": [1 item
{2 fields
"verwendungszwecke": [2 items
{2 fields
"zweck": [1 item
{2 fields
"zweck": [1 item
"MESSLOKATION": [1 item
{12 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{4 fields
"zaehlzeiten": {1 field
"ablesekartenempfaenger": {7 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [3 items
{8 fields
{6 fields
{6 fields
"TECHNISCHE_RESSOURCE": [1 item
{12 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"STEUERBARE_RESSOURCE": [1 item
{10 fields
"auftraggebenderMarktpartner": {4 fields
"marktrollen": [1 item
{7 fields
"zugeordneteDefinition": {1 field
"LOKATIONSBUENDEL": [1 item
{5 fields
"zuordnungObjectcode": [4 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"MESSSTELLENBETRIEBSVERTRAG": [1 item
{9 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"vertragskonditionen": {1 field
"geplanteTurnusablesung": {1 field
"korrespondenzpartner": {6 fields
"partneradresse": {5 fields
"ENERGIELIEFERVERTRAG": [1 item
{7 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"ZAEHLER": [1 item
{13 fields
"zaehlwerke": [1 item
{4 fields
"geraete": [1 item
{1 field
"BILANZIERUNG": [1 item
{9 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {12 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9904446000007:500+{{date}}:{{time}}+M3FXU3PV'
UNH+UNHM44RYD60+UTILMD:D:11A:UN:S2.1'
BGM+E01+BGMM42HSI1V'
DTM+137:202604011200?+00:303'
NAD+MS+9900321000005::293'
NAD+MR+9904446000007::293'
IDE+24+123456'
DTM+76:202606302200?+00:303'
STS+7++E03'
LOC+Z18+E1688117482'
LOC+Z16+50074561188'
LOC+Z20+D417MLM8164'
LOC+Z19+C816417ST77'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55168'
RFF+Z50:50074561188'
DTM+752:0101:106'
SEQ+Z78'
RFF+Z31:9992000000026'
SEQ+Z58'
RFF+Z32:E1688117482'
RFF+Z33:9992000001256'
SEQ+Z58'
RFF+Z18:50074561188'
RFF+Z33:9992000001016'
SEQ+Z58'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001032'
SEQ+Z58'
RFF+Z37:D417MLM8164'
RFF+Z33:9992000001024'
SEQ+Z51'
RFF+Z32:E1688117482'
CCI+Z49++ZF3'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+Z57'
RFF+Z32:E1688117482'
PIA+5+1-1?:5.29.0:SRW'
CCI+++ZA8'
CAV+ZD1'
CCI+++ZA7'
CAV+ZD1'
SEQ+Z60'
RFF+Z32:E1688117482'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
CCI+++ZB3'
CAV+Z88:9900321000005'
CCI+++ZA8'
SEQ+Z01'
RFF+Z18:50074561188'
QTY+31:2000:KWH'
CCI+Z30++Z07'
CCI+++ZB3'
CAV+Z89:9903790000002'
CAV+Z90:4045399000077'
CAV+Z91:9904446000007::Z39:Z20'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+6++ZA8'
CCI+++ZA6'
CAV+E02'
CCI+ZA2++ZE9'
SEQ+Z27'
RFF+Z18:50074561188'
PIA+5+9991000000044:Z11'
CCI+Z41'
CCI+++ZA8'
CAV+ZE1'
CCI+++ZA7'
CAV+Z47'
SEQ+Z52'
RFF+Z37:D417MLM8164'
RFF+Z34:DE0032106765712000000000000000037'
RFF+Z16:50074561188'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+Z62'
RFF+Z38:C816417ST77'
CCI+Z49'
CAV+ZF2:Z14'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+Z61'
RFF+Z38:C816417ST77'
PIA+5+9991000000713:Z12'
CCI+Z52++ABC'
CCI+++ZB3'
CAV+Z88:9900321000005'
CCI+++ZA8'
SEQ+Z18'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z16:50074561188'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39:Z20'
CAV+ZF0:9904446000007'
CAV+ZB4:9904446000007'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
CCI+Z32++ZC3'
SEQ+Z19'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z18:50074561188'
PIA+5+9991000000151:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
CCI+Z41'
SEQ+Z03'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::EL001IK01013852469'
CAV+ETZ'
CAV+ERZ'
CAV+Z58:::Z07'
CCI+++Z28'
CAV+BKE'
CCI+++E12'
CAV+MMR'
SEQ+Z20'
RFF+MG:EL001IK01013852469'
RFF+Z19:DE0032106765712000000000000000037'
PIA+5+1-1?:1.8.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::7:3'
SEQ+Z21'
RFF+Z18:50074561188'
CCI+Z02++E01'
CAV+H0'
NAD+Z09+++Mustermann:Max::::Z01'
RFF+Z18:50074561188'
NAD+Z07+++Mustermann:Max::::Z01'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z08+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
NAD+Z03++Mustermann:Max++Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z05+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
UNT+149+UNHM44RYD60'
UNZ+1+M3FXU3PV'[1 item
{6 fields
"data": {3 fields
"stammdaten": {11 fields
"MARKTLOKATION": [1 item
{10 fields
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{3 fields
"verwendungszwecke": [2 items
{2 fields
{2 fields
"zweck": [1 item
"zaehlzeiten": {1 field
"NETZLOKATION": [1 item
{11 fields
"auftraggebenderMarktpartner": {4 fields
"marktrollen": [1 item
{7 fields
"zaehlwerke": [1 item
{2 fields
"verwendungszwecke": [2 items
{2 fields
"zweck": [1 item
{2 fields
"zweck": [1 item
"MESSLOKATION": [1 item
{12 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{4 fields
"zaehlzeiten": {1 field
"ablesekartenempfaenger": {7 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [3 items
{8 fields
{6 fields
{6 fields
"TECHNISCHE_RESSOURCE": [1 item
{12 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"STEUERBARE_RESSOURCE": [1 item
{10 fields
"auftraggebenderMarktpartner": {4 fields
"marktrollen": [1 item
{7 fields
"zugeordneteDefinition": {1 field
"LOKATIONSBUENDEL": [1 item
{5 fields
"zuordnungObjectcode": [4 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"MESSSTELLENBETRIEBSVERTRAG": [1 item
{9 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"vertragskonditionen": {1 field
"geplanteTurnusablesung": {1 field
"korrespondenzpartner": {6 fields
"partneradresse": {5 fields
"ENERGIELIEFERVERTRAG": [1 item
{7 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"ZAEHLER": [1 item
{13 fields
"zaehlwerke": [1 item
{4 fields
"geraete": [1 item
{1 field
"BILANZIERUNG": [1 item
{9 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {12 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | End of metering point operation | WiM electricity part 1 | Electricity | Step 3 |
| NB | NB | End of metering point operation | WiM electricity part 1 | Electricity | Step 7 |
| MSB | GMSB | End of metering point operation | WiM electricity part 1 | Electricity | Step 3 |
| MSB | GMSB | End of metering point operation | WiM electricity part 1 | Electricity | Step 7 |
| MSB | MSBA | End of metering point operation | WiM electricity part 1 | Electricity | Step 3 |
| MSB | MSBA | End of metering point operation | WiM electricity part 1 | Electricity | Step 7 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Commitment request / demand |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | End of metering point operation | NB → MSB (corresponds to gMSB on the metering location object) | Commitment request |
| WiM electricity part 1 | End of metering point operation | NB → MSB (corresponds to gMSB on the metering location object) | Request to take over the individual metering location by the gMSB |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Which messages respond to this
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | 55169 | Confirmation of commitment request | UTILMD | from the step sequence |
| Response | 55170 | Rejection commitment request | UTILMD | from the step sequence |
This column is the inverse of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 814 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 2 transactions for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.