Check identifier 55224 — Response to DZÜ list
Check identifier 55224 · EDIFACT message type UTILMD · format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55224 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
006800070 | General assignment reference | — | — | S [1] |
007000080 | Transmission sequence number | — | — | M [252] |
0073 C00090 | Start | — | — | M [2] |
0073 F00100 | End | — | — | S [3] |
| BGM | — | — | Must | — |
1001 Z3700110 | DZÜ list | — | X | — |
100400120 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700130 | Document-/message date/time | — | X | — |
238000140 | Date or time or time span, value | — | X | [931] [494] |
2379 30300150 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 15700160 | Validity, start date | — | X | — |
238000170 | Date or time or time span, value | — | X | — |
2379 61000180 | CCYYMM | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00190 | Document-/message sender or sender | — | X | — |
303900200 | MP-ID | — | X | — |
3055 900210 | GS1 | — | X | — |
3055 29300220 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00230 | Information contact | — | X | — |
341200240 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800250 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00260 | Electronic mail | — | X | [1P0..1] |
3155 FX00270 | Fax number | — | X | [1P0..1] |
3155 TE00280 | Telephone | — | X | [1P0..1] |
3155 AJ00290 | further telephone | — | X | [1P0..1] |
3155 AL00300 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00310 | Message recipient | — | X | — |
303900320 | MP-ID | — | X | [280] |
3055 900330 | GS1 | — | X | — |
3055 29300340 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | [564] |
7495 Z0100350 | List | — | X | — |
740200360 | List number | — | X | — |
| SG4.STS | — | — | Must | [238] |
9015 E0100370 | Status of the response | — | X | — |
901300380 | Code of the check step | — | X | — |
1131 E_007000390 | EBD no. E_0070 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500400 | MaBiS metering point | — | X | — |
322500410 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300420 | Check identifier | — | X | — |
1154 5522400430 | MaBiS / response to DZÜ list | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00440 | Transaction reference number | — | X | — |
115400450 | Reference, identification | — | X | [655] |
| SG8.SEQ | — | — | Must | — |
1229 Z2200460 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AUU00470 | Reference to a time series | — | X | — |
115400480 | Version of the time series | — | X | — |
| SG4.IDE | — | — | Must | [565] |
7495 2400490 | Transaction | — | X | — |
740200500 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 E0100510 | Status of the response | — | X | — |
901300520 | Code of the check step | — | X | — |
1131 E_007000530 | EBD no. E_0070 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1600540 | Market location | — | X | — |
322500550 | ID of the market location | — | X | [950] [528] |
| SG5.LOC | — | — | Must | — |
3227 Z2100560 | Tranche | — | X | — |
322500570 | ID of the tranche | — | X | [950] [528] |
| SG6.RFF | — | — | Must | — |
1153 TN00580 | Transaction reference number | — | X | — |
115400590 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z7200600 | Data status of the NB | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3100610 | Estimated annual quantity total | — | X | — |
606000620 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00630 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4500640 | Energy quantity to be balanced | — | X | — |
606000650 | Quantity specification | — | X | — |
6411 KWH00660 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15800670 | Start of balancing | — | X | — |
238000680 | Date or time or time span, value | — | X | [UB1] ∧ [454] |
2379 30300690 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15900700 | End of balancing | — | X | — |
238000710 | Date or time or time span, value | — | X | [UB1] ∧ [455] |
2379 30300720 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900730 | Balancing group | — | X | — |
703700740 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2000750 | Balancing area | — | X | — |
703700760 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500770 | Structure | — | X | — |
7037 Z2100780 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100790 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0200800 | Standard load profile | — | X | — |
7059 Z0400810 | Standard feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711100820 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 600830 | Responsible party | — | X | — |
7037 ZA800840 | NB | — | X | — |
7037 ZA900850 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZG300860 | Location in regular operation | — | X | — |
7111 ZG400870 | Location outside regular operation (decommissioning) | — | X | — |
| UNT | — | — | Must | — |
007400880 | Number of segments in a message | — | X | — |
006200890 | Message reference number | — | X | — |
Conditions of this table
The free text of the 25 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [1] | If a split is present |
| [2] | If UNH DE0070 (transmission sequence number) with 1 is present |
| [3] | In the case of splitting, in the message with the highest transmission sequence number |
| [238] | If SG4 IDE+24 (transaction) is not present |
| [252] | If DE0068 is present |
| [280] | Only MP-ID from the electricity division |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [454] | The balancing start date must be earlier than the balancing end date in the SG8 “Data status of the ÜNB”, SG 9 energy quantity DZÜ share |
| [455] | The balancing end date must be later than the balancing start date in the SG8 “Data status of the ÜNB” , SG 9 energy quantity DZÜ share |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [528] | Note: The date/dates from the request must be used |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [655] | Note: The list number from the DZÜ list must be used |
| [902] | Format: Possible value: ≥ 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB, ÜNB and BIKO.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Transmission of validation notification of the delta time series transfer from NB via BIKO to ÜNB | MaBiS | Electricity | Step 2 |
| ÜNB | ÜNB | Transmission of validation notification of the delta time series transfer from NB via BIKO to ÜNB | MaBiS | Electricity | Step 2 |
| BIKO | BIKO | Transmission of validation notification of the delta time series transfer from NB via BIKO to ÜNB | MaBiS | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to DZÜ list |
| AHB | UTILMD AHB electricity |
| Decision tree | E_0070 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the validation notification for the delta time series transfer from NB via BIKO to ÜNB | NB → ÜNB | Correction of DZÜ list |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 123 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.