Check identifier 55076 — Response to master data change
Check identifier 55076 · EDIFACT message type UTILMD · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55076 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00150 | Information contact | — | X | — |
341200160 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800170 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00180 | Electronic mail | — | X | [1P0..1] |
3155 FX00190 | Fax number | — | X | [1P0..1] |
3155 TE00200 | Telephone | — | X | [1P0..1] |
3155 AJ00210 | further telephone | — | X | [1P0..1] |
3155 AL00220 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00230 | Message recipient | — | X | — |
303900240 | MP-ID | — | X | [280] |
3055 900250 | GS1 | — | X | — |
3055 29300260 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400270 | Transaction | — | X | — |
740200280 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 15700290 | Validity, start date | — | X | — |
238000300 | Date or time or time span, value | — | X | [UB1] |
2379 30300310 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700320 | Transaction reason | — | X | — |
9013 E0300330 | Change | — | X | — |
9013 ZE300340 | Master data change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100350 | Status of the response | — | X | — |
901300360 | Code of the check step | — | X | — |
1131 S_009100370 | Electricity code list no. S_0091 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1600380 | Market location | — | X | — |
322500390 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2100400 | Tranche | — | X | — |
322500410 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700420 | Metering location | — | X | — |
322500430 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300440 | Check identifier | — | X | — |
1154 5507600450 | HKNR / Response to master data change | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00460 | Transaction reference number | — | X | — |
115400470 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0100480 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800490 | Market location | — | X | — |
115400500 | ID of the market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 ZB300510 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8900520 | LF | — | X | — |
113100530 | MP-ID | — | X | [611] |
| SG10.CCI | — | — | Must | — |
7059 Z1900540 | Balancing group | — | X | — |
703700550 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500560 | Structure | — | X | — |
7037 Z2100570 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100580 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z3400590 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3300600 | EEG market location without DV obligation | — | X | — |
7111 Z3400610 | KWKG market location without DV obligation | — | X | — |
7111 Z3500620 | other market location | — | X | — |
7111 Z3700630 | EEG market location with DV obligation | — | X | — |
7111 Z4600640 | KWKG market location with DV obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2200650 | Statutory category | — | X | — |
7037 Z9000660 | EEG marketing type: default remuneration | — | X | [695] |
7037 Z9100670 | EEG marketing type: market premium | — | X | [696] |
7037 Z9200680 | Marketing type without statutory remuneration | — | X | [696] |
7037 Z9400690 | KWKG remuneration | — | X | [695] |
| SG10.CCI | — | — | Must | — |
7059 Z2300700 | Country of production | — | X | — |
703700710 | Country of production | — | X | — |
1131 LAND00720 | EDI@Energy code list of European country codes | — | X | — |
3055 29300730 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0200740 | OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800750 | Market location | — | X | — |
115400760 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 500770 | Product identification | — | X | — |
714000780 | OBIS code of the market location | — | X | [314] |
7143 SRW00790 | OBIS code | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1500800 | Data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2000810 | Tranche | — | X | — |
115400820 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 1100830 | Distribution quantity | — | X | — |
606000840 | Quantity specification in % | — | X | [914] ∧ [930] ∧ [955] |
6411 P100850 | Percent | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300860 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8900870 | LF | — | X | — |
113100880 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900890 | Balancing group | — | X | — |
703700900 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3700910 | Basis for determining the tranche size | — | X | — |
7037 ZD100920 | Percentage-based | — | X | — |
7037 ZD200930 | Distribution factor based on reference carrier/installed capacity | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1700940 | OBIS data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2000950 | Tranche | — | X | — |
115400960 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 500970 | Product identification | — | X | — |
714000980 | OBIS code of the tranche | — | X | [269] |
7143 SRW00990 | OBIS code | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0301000 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901010 | Metering location | — | X | — |
115401020 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1401030 | Smart meter gateway | — | X | — |
115401040 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1301050 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ01060 | analog household meter (three-phase current) | — | X | — |
7111 WSZ01070 | analog alternating current meter | — | X | — |
7111 LAZ01080 | Load curve meter | — | X | — |
7111 MAZ01090 | Maximum demand meter | — | X | — |
7111 MME01100 | modern metering device according to MsbG | — | X | — |
7111 EHZ01110 | electronic household meter | — | X | — |
7111 IVA01120 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001130 | Device number | — | X | — |
711001140 | Device number | — | X | — |
| SG10.CAV | — | — | Must | [139] |
7111 ETZ01150 | Single tariff | — | X | — |
7111 ZTZ01160 | Two-tariff | — | X | — |
7111 NTZ01170 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ERZ01180 | Single-direction meter | — | X | — |
7111 ZRZ01190 | Bidirectional meter | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2001200 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [665] |
1153 MG01210 | Device number of the meter | — | X | [441] |
1153 Z1401220 | Smart meter gateway | — | X | — |
115401230 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901240 | Metering location | — | X | — |
115401250 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK01260 | Application reference number | — | X | — |
115401270 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501280 | Product identification | — | X | — |
714001290 | OBIS code of the metering device | — | X | [323] |
7143 SRW01300 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401310 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901320 | Annually | — | X | — |
7111 ZE801330 | Semi-annual | — | X | — |
7111 ZE901340 | Quarterly | — | X | — |
7111 ZB701350 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1101360 | Product | — | X | — |
7037 Z3301370 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001380 | Digits before the decimal point | — | X | — |
711001390 | Digits after the decimal point | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0401400 | Instrument transformer data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01410 | Device number of the meter | — | X | — |
115401420 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2501430 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3001440 | Device number | — | X | — |
711001450 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW01460 | Current transformer set | — | X | — |
7111 MPW01470 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW01480 | Block current transformer | — | X | — |
7111 MUW01490 | Voltage transformer set | — | X | — |
711001500 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 Z1301510 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7501520 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001530 | Device number | — | X | — |
711001540 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z1401550 | Control box | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1401560 | Smart meter gateway | — | X | — |
115401570 | Identification / number of the smart meter gateway | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801580 | Market location | — | X | — |
115401590 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 Z7601600 | Control box | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001610 | Device number | — | X | — |
711001620 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 VY01630 | other associated party | — | X | — |
303901640 | MP-ID | — | X | — |
3055 901650 | GS1 | — | X | — |
3055 29301660 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1801670 | Market location | — | X | — |
1153 Z2001680 | Tranche | — | X | — |
115401690 | ID of a market location / tranche | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 DP01700 | Supply address | — | X | — |
312401710 | Additional information for identification | — | — | — |
304201720 | Street and house number or PO box | — | — | S [166] M [212] |
316401730 | City | — | X | — |
325101740 | Postal code | — | X | — |
320701750 | Country name, code | — | X | — |
| UNT | — | — | Must | — |
007401760 | Number of segments in a message | — | X | — |
006201770 | Message reference number | — | X | — |
Conditions of this table
The free text of the 35 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [139] | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| [269] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3, that are required at the tranche must be stated |
| [280] | Only MP-ID from the electricity division |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [695] | Note: Use if the role LF is assigned to a company NB |
| [696] | Note: Use only if the role LF is not assigned to a company NB |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer) is present, the segment must be specified exactly once |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
There is no role view for this check identifier: in this format version no process step of any market role carries it. A role statement would stand here without evidence.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to master data change |
| AHB | UTILMD AHB electricity |
| Transmission channel | MP |
This check identifier is used in 3 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 1 No. 2 | RB HKN-R → NB | Response to master data change |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 2 No. 2 | RB HKN-R → NB | Response to master data change |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 4 No. 2 | RB HKN-R → NB | Response to master data change |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 251 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.