Check identifier 55634 — Response message/request for data of MaLo
Check identifier 55634 · EDIFACT message type UTILMD · format version 202610
Data structure
| Structure (BO4E) | Description | Format | 55634 | Condition |
|---|---|---|---|---|
| stammdaten | — | object | May | — |
| BILANZIERUNG [ ] | — | object[] | May | — |
| abwicklungsmodell 00010 | Processing model | Enum Abwicklungsmodell | Must | — |
MODELL_1_BILANZIERUNG_AN_MARKTLOKATION | — | — | Must | — |
MODELL_2_BILANZIERUNG_IM_BILANZIERUNGSGEBIET | — | — | Must | — |
| datenqualitaet 00020 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| detailsPrognosegrundlage 00030 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| prognosegrundlage 00040 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00050 | zeitraumId | integer | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00080 | Designation of the profile | string | Must | — |
| einspeisung 00090 | Feed-in indicator | boolean | Must | — |
| profilart 00100 | Profile category | Enum Profilart | Must | — |
ART_STANDARDLASTPROFIL | — | — | Must | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | Must | — |
ART_LASTPROFIL | — | — | Must | — |
| referenzprofilbezeichnung 00110 | Designation of the reference profile | string | Must | — |
| verfahren 00120 | Profiling method | Enum Profilverfahren | Must | — |
SYNTHETISCH | — | — | Must | — |
ANALYTISCH | — | — | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00130 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00140 | Value | number (float) | Must | — |
| MARKTLOKATION [ ] | — | object[] | May | — |
| datenqualitaet 00150 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| marktlokationsId 00160 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00170 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00180 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| umspannung 00190 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| eigentuemer | — | object | May | — |
| anrede 00200 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| gewerbekennzeichnung 00210 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | Must | — |
| name1 00220 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00230 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00240 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00250 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00260 | House number and supplement | string | Must | — |
| landescode 00270 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00280 | City | string | Must | — |
| ortsteil 00290 | District | string | Must | — |
| postfach 00300 | PO box | string | Must | — |
| postleitzahl 00310 | Postal code | string | Must | — |
| strasse 00320 | Street | string | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00330 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00340 | zeitraumId | integer | X | — |
| hausverwalter | — | object | May | — |
| anrede 00350 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| gewerbekennzeichnung 00360 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | Must | — |
| name1 00370 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00380 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00390 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00400 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00410 | House number and supplement | string | Must | — |
| landescode 00420 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00430 | City | string | Must | — |
| ortsteil 00440 | District | string | Must | — |
| postfach 00450 | PO box | string | Must | — |
| postleitzahl 00460 | Postal code | string | Must | — |
| strasse 00470 | Street | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00480 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00490 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00500 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00510 | weiterverpflichtet | boolean | X | — |
| NETZNUTZUNGSVERTRAG [ ] | — | object[] | May | — |
| datenqualitaet 00520 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00530 | zeitraumId | integer | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00540 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| name1 00550 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00560 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00570 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00580 | name4 | string | Must | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00590 | Email address | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00600 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00610 | rufnummer | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00620 | House number and supplement | string | Must | — |
| landescode 00630 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00640 | City | string | Must | — |
| ortsteil 00650 | District | string | Must | — |
| postfach 00660 | PO box | string | Must | — |
| postleitzahl 00670 | Postal code | string | Must | — |
| strasse 00680 | Street | string | Must | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00690 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| geschaeftspartnerrolle 00700 | Role held by the business partner (e.g. prospect, customer). | array | Must | — |
| name1 00710 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00720 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00730 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00740 | name4 | string | Must | — |
| VERWENDUNGSZEITRAUM [ ] | — | object[] | May | — |
| datenqualitaet 00750 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| verwendungAb 00760 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00770 | verwendungBis | string (date-time) | X | — |
| zeitraumId 00780 | zeitraumId | integer | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer 00790 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00800 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00810 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00820 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00830 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00840 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00850 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| transaktionsgrundergaenzung * 00860 | Supplement to the transaction reason / UTILMD STS+7++E01+###+E03 | string | X | — |
| vorgangsnummer * 00870 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00880 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00890 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| antwortStatusZeitraum [ ] | — | object[] | May | — |
| code 00900 | code | string | X | — |
| liste 00910 | liste | string | X | — |
| zeitraumId 00920 | zeitraumId | integer | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00930 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00940 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55634 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | [705] |
1001 Z8800080 | Request for data clearing | — | X | [706] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document-/ message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMM ZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00130 | Document/message issuer or sender | — | X | — |
303900140 | MP-ID | — | X | — |
3055 900150 | GS1 | — | X | — |
3055 29300160 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00170 | Message recipient | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400210 | Transaction | — | X | — |
740200220 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700230 | Transaction reason | — | X | — |
9013 ZX600240 | Change data of the MaLo | — | X | — |
9013 ZW300250 | Generating market location | — | X | — |
9013 ZW400260 | Consuming market location | — | X | — |
| SG4.STS | — | — | Must | [301] ∧ [557] ∧ [2011] |
9015 E0100270 | Status of the response | — | X | — |
901300280 | Code of the check step | — | X | — |
1131 E_040900290 | EBD no. E_0409 | — | X | — |
901200300 | Time period ID from the change notification of the responsible party | — | X | [914] ∧ [937] ∧ [44] |
| SG5.LOC | — | — | Must | — |
3227 Z1600310 | Market location | — | X | — |
322500320 | ID of the market location | — | X | [950] |
| SG6.RFF | — | — | Must | — |
1153 Z1300330 | Check identifier | — | X | — |
1154 5563400340 | GPKE / Response message / Request for data of the MaLo from MSB to NB | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00350 | Transaction reference number | — | X | — |
115400360 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z4700370 | Data available in the system | — | X | [5P0..n] |
1153 Z4800380 | Expected data | — | X | [2P0..n] |
1153 Z5400390 | No data available in the system | — | X | [4P0..n] |
1153 Z5500400 | No data expected | — | X | [2P0..n] |
115600410 | Time period ID | — | X | [914] ∧ [937] [127] ⊻ [128] |
| SG6.DTM | — | — | Must | [131] ⊻ [134] ⊻ [135] |
2005 Z2500420 | Data used from | — | X | — |
238000430 | Date or time or time span, value | — | X | [UB1] |
2379 30300440 | CCYYMMDDHHMM ZZZ | — | X | — |
| SG6.DTM | — | — | Must | [472] ⊻ [473] |
2005 Z2600450 | Data used until | — | X | — |
238000460 | Date or time or time span, value | — | X | [UB1] |
2379 30300470 | CCYYMMDDHHMM ZZZ | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z8000480 | Expected data of the market location | — | X | [2P0..n] |
1229 Z8100490 | Data of the market location existing in the system | — | X | [3P0..n] |
105000500 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG9.QTY | — | — | Must | — |
6063 Z1000510 | Power of the market location | — | X | [102] |
6063 26500520 | Estimated annual quantity total/ annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0800530 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606000540 | Quantity | — | X | [902] |
6411 Z1600550 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH00560 | Kilowatt hour | — | X | [104] |
6411 KWT00570 | Kilowatt | — | X | [105] |
| SG9.QTY | — | — | Must | — |
6063 3100580 | Estimated annual quantity total | — | X | — |
606000590 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00600 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300610 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9000620 | ÜNB | — | X | — |
113100630 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100640 | MSB | — | X | — |
113100650 | MP-ID | — | X | — |
7110 Z3900660 | Default metering point operator | — | X | — |
7110 Z4000670 | Competitive metering point operator | — | X | — |
7110 Z4100680 | Fallback metering point operator | — | X | — |
7110 Z1900690 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2000700 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0300710 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0300720 | Extra-high voltage | — | X | — |
7111 E0400730 | High voltage | — | X | — |
7111 E0500740 | Medium voltage | — | X | — |
7111 E0600750 | Low voltage | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 E0700760 | EHV/HV transformation | — | X | [116] |
7111 E0800770 | HV/MV transformation | — | X | [115] |
7111 E0900780 | MS/NS transformation | — | X | [114] |
| SG10.CCI | — | — | Must | — |
7037 Z8300790 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5200800 | iMS | — | X | — |
7111 Z5300810 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC000820 | Forecast based on values | — | X | — |
7037 ZA600830 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [210] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0200840 | SLP/SEP | — | X | [1P0..1] |
7111 E1400850 | TLP/TEP | — | X | [1P0..1] |
7111 Z3600860 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3400870 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3300880 | EEG market location without DV obligation | — | X | — |
7111 Z3400890 | KWKG- Market location without direct marketing obligation | — | X | — |
7111 Z3500900 | other market location | — | X | — |
7111 Z3700910 | EEG market location with DV obligation | — | X | — |
7111 Z4600920 | KWKG- Market location with direct marketing obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 ZA200930 | Handling model | — | X | — |
7037 ZE900940 | Model 1 "Balancing at the market location" | — | X | — |
7037 ZF000950 | Model 2 "Balancing in the balancing area (BG) of the LPB" | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z8500960 | Expected profile data | — | X | [2P0..n] |
1229 Z8600970 | Profile data available in the system | — | X | [3P0..n] |
105000980 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7059 Z0200990 | Standard load profile | — | X | — |
7059 Z0401000 | Standard feed-in profile | — | X | — |
7037 E0101010 | synthetic method | — | X | — |
7037 Z1001020 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711101030 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z8701040 | Expected profile set data | — | X | [2P0..n] |
1229 Z8801050 | Profile shard data available in the system | — | X | [3P0..n] |
105001060 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7059 Z0301070 | day-parameter-dependent load profile | — | X | — |
7059 Z0501080 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0101090 | synthetic method | — | X | — |
7037 Z1001100 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711101110 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z8901120 | Expected reference profile data | — | X | [2P0..n] |
1229 Z9001130 | Reference profile data available in the system | — | X | [3P0..n] |
105001140 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
705901150 | Class type, code | — | X | — |
| SG10.CAV | — | — | Must | — |
711101160 | Code of the reference profile | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z5101170 | Expected customer of the grid operator | — | X | — |
3035 Z5201180 | Customer of the grid operator available in the system | — | X | — |
303601190 | Name | — | X | — |
3045 Z0101200 | Structure of person names | — | X | — |
3045 Z0201210 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601220 | Reference to time period ID | — | X | — |
115401230 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z5301240 | Expected correspondence address of the grid operator's customer | — | X | — |
3035 Z5401250 | Correspondence address of the customer of the grid operator available in the system | — | X | — |
303601260 | Name | — | X | — |
3045 Z0101270 | Structure of person names | — | X | — |
3045 Z0201280 | Structure of the company name | — | X | — |
304201290 | Street and house number or PO box | — | X | — |
316401300 | City | — | X | — |
325101310 | Postal code | — | — | M [268] S [166] |
320701320 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601330 | Reference to time period ID | — | X | — |
115401340 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG13.CTA | — | — | Must | — |
3139 IC01350 | Information contact | — | X | — |
| SG13.COM | — | — | Must | — |
314801360 | Number / address | — | X | — |
3155 TE01370 | Telephone | — | X | [1P0..1] |
3155 EM01380 | Electronic mail | — | X | [1P0..1] |
| SG12.NAD | — | — | Must | — |
3035 Z5501390 | Expected connection holder | — | X | — |
3035 Z5601400 | Connection holder available in the system | — | X | — |
303601410 | Name | — | X | — |
3045 Z0101420 | Structure of person names | — | X | — |
3045 Z0201430 | Structure of the company name | — | X | — |
304201440 | Street and house number or PO box | — | X | — |
316401450 | City | — | X | — |
325101460 | Postal code | — | — | M [268] S [166] |
320701470 | Country name, code | — | — | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601480 | Reference to time period ID | — | X | — |
115401490 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z5701500 | Expected property manager | — | X | — |
3035 Z5801510 | Property manager available in the system | — | X | — |
303601520 | Name | — | X | — |
3045 Z0101530 | Structure of person names | — | X | — |
3045 Z0201540 | Structure of the company name | — | X | — |
304201550 | Street and house number or PO box | — | X | — |
316401560 | City | — | X | — |
325101570 | Postal code | — | — | M [268] S [166] |
320701580 | Country name, code | — | — | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601590 | Reference to time period ID | — | X | — |
115401600 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| UNT | — | — | Must | — |
007401610 | Number of segments in a message | — | X | — |
006201620 | Message reference number | — | X | — |
Conditions of this table
The free text of the 40 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [8] | If required for data clearing |
| [22] | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| [44] | The time period ID from DE1156 of a matching SG6 RFF+Z49/Z53 (usage period of the data: "valid data", "no data") from the request message from SG6 RFF+TN DE1154 ((reference transaction number (from request message)) must be entered |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [102] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+Z36 (TEP with ref. measurement) present in this SG8 |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [105] | If SG9 QTY+Z10 (energy / power for day-parameter-dependent market location: power of the market location) present in this SG8 |
| [114] | If the SG10 CCI+E03 (voltage level of the market location) CAV E06 (low voltage) is present in this SG |
| [115] | If the SG10 CCI+E03 (voltage level of the market location) CAV E05 (medium voltage) is present in this SG |
| [116] | If the SG10 CCI+E03 (voltage level of the market location) CAV E04 (high voltage) is present in this SG |
| [127] | The value resulting from the number of repetitions of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) must be entered. This means: the first SG6 RFF+Z48/Z55 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [128] | The value resulting from the number of repetitions of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) must be entered. This means: the first SG6 RFF+Z47/Z54 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [131] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage peri od of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message dat e) at 0:00, or a day earlier than that at 0:00 German time |
| [134] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with the next lower time period ID in DE1156 |
| [135] | If this DTM+Z25 (use of the data from) is not in SG6 RFF+Z47/Z54 (usage perio d of the data: data present in the system/no data present in the system) with the time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of the data until) of the SG6 RFF+Z47/Z54 (usage perio d of the data: data present in the system/no data present in the system) with the next lower time period ID in DE1156 |
| [166] | If present |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [301] | If BGM+E03 (change notification ) present |
| [472] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) which is lower than in another SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) DE1156 (time period ID) |
| [473] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) which is lower than in another SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) DE1156 (time period ID) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [557] | Note: If the responsible party has sent more than eight usage periods, eight arbitrary usage periods are answered |
| [705] | Note: If the action of a sequence diagram "Response message on change" is carried out |
| [706] | Note: If the action of a sequence diagram "Order placement of a change of master data..." is carried out with the aim of performing a data clearing |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [950] | Format: market location ID |
| [2011] | Segment group must be specified exactly once for each time period ID from DE1156 of the SG6 RFF+Z49 / Z53 (usage period of the data: "Valid data" / "No data") from the request message from SG6 RFF+TN DE1154 (reference transaction number (from request message)) |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [5P0..n] | [315] If BGM+Z88 (data clearing) present [20 13 ] To be specified at least once , if no SG6 RFF+Z54 (Usage period of the data: no data present in the system) present |
| [2P0..n] | [301] If BGM+E03 (change notification) present [315] If BGM+Z88 (data clearing) present |
| [4P0..n] | [315] If BGM+Z88 (data clearing) present [20 14 ] To be specified at least once , if no SG6 RFF+Z47 (Usage period of the data: data present in the system) present |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [3P0..n] | [315] If BGM+Z88 (data clearing) present |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9910812000000:500+9900327000009:500+{{date}}:{{time}}+DARBBWTPSBVNKX'
UNH+DAWBDMIKKERHKR+UTILMD:D:11A:UN:S2.2'
BGM+E03+DA262410220812389903323000007090610'
DTM+137:202610021100?+00:303'
NAD+MS+9910812000000::293'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZX6+ZW4'
STS+E01++A02:E_0409::1'
STS+E01++A02:E_0409::2'
LOC+Z16+20072281644'
RFF+Z13:55634'
RFF+TN:NNV1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z80+1'
QTY+31:4000:KWH'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+E02'
CCI+ZA2++ZE9'
SEQ+Z80+2'
QTY+31:4100:KWH'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+E02'
CCI+ZA2++ZE9'
SEQ+Z85+1'
CCI+Z02++E01'
CAV+XYZ'
SEQ+Z85+2'
CCI+Z02++E01'
CAV+XYZ'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:1'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:1'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:2'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:2'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
UNT+66+DAWBDMIKKERHKR'
UNZ+1+DARBBWTPSBVNKX'[1 item
{6 fields
"data": {3 fields
"stammdaten": {4 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"MARKTLOKATION": [2 items
{12 fields
"gueltigkeitszeitraum": {3 fields
"marktrollen": [2 items
{6 fields
{8 fields
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
{12 fields
"gueltigkeitszeitraum": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"NETZNUTZUNGSVERTRAG": [2 items
{10 fields
"gueltigkeitszeitraum": {3 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
{10 fields
"gueltigkeitszeitraum": {2 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
"BILANZIERUNG": [2 items
{9 fields
"gueltigkeitszeitraum": {3 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
{9 fields
"gueltigkeitszeitraum": {2 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {14 fields
"absender": {5 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9910812000000:500+9900327000009:500+{{date}}:{{time}}+DAIUIHDBGNDQCV'
UNH+DAWHPFFDUZEGZP+UTILMD:D:11A:UN:S2.2'
BGM+E03+DA102410220806209903323000007895460'
DTM+137:202610021100?+00:303'
NAD+MS+9910812000000::293'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZX6+ZW4'
STS+E01++A02:E_0409::1'
STS+E01++A02:E_0409::2'
LOC+Z16+20072281644'
RFF+Z13:55634'
RFF+TN:NNV1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z80+1'
QTY+265:3:Z16'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+E14'
CCI+ZA2++ZE9'
SEQ+Z80+2'
QTY+265:3:Z16'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+E14'
CCI+ZA2++ZE9'
SEQ+Z87+1'
CCI+Z03++E01'
CAV+XYZ'
SEQ+Z87+2'
CCI+Z03++E01'
CAV+XYZ'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:1'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:1'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:2'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:2'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
UNT+66+DAWHPFFDUZEGZP'
UNZ+1+DAIUIHDBGNDQCV'[1 item
{6 fields
"data": {3 fields
"stammdaten": {4 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"MARKTLOKATION": [2 items
{12 fields
"gueltigkeitszeitraum": {3 fields
"marktrollen": [2 items
{6 fields
{8 fields
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
{12 fields
"gueltigkeitszeitraum": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"NETZNUTZUNGSVERTRAG": [2 items
{10 fields
"gueltigkeitszeitraum": {3 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
{10 fields
"gueltigkeitszeitraum": {2 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
"BILANZIERUNG": [2 items
{9 fields
"gueltigkeitszeitraum": {3 fields
"lastprofile": [1 item
{5 fields
"temperaturarbeit": {2 fields
"detailsPrognosegrundlage": [1 item
{9 fields
"gueltigkeitszeitraum": {2 fields
"lastprofile": [1 item
{5 fields
"temperaturarbeit": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {14 fields
"absender": {5 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9910812000000:500+9900327000009:500+{{date}}:{{time}}+DAYKDYVSLAJQWH'
UNH+DAAFSOQVKKNGXK+UTILMD:D:11A:UN:S2.2'
BGM+E03+DA172410220759199903323000007215798'
DTM+137:202610021100?+00:303'
NAD+MS+9910812000000::293'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZX6+ZW3'
STS+E01++A02:E_0409::1'
STS+E01++A02:E_0409::2'
LOC+Z16+20072281644'
RFF+Z13:55634'
RFF+TN:NNV1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z80+1'
QTY+Z10:3:KWT'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+Z36'
CCI+++Z34'
CAV+Z33'
CCI+ZA2++ZE9'
SEQ+Z80+2'
QTY+Z10:3:KWT'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+Z36'
CCI+++Z34'
CAV+Z33'
CCI+ZA2++ZE9'
SEQ+Z89+1'
CCI+Z05'
CAV+XYZ'
SEQ+Z89+2'
CCI+Z05'
CAV+XYZ'
UNT+54+DAAFSOQVKKNGXK'
UNZ+1+DAYKDYVSLAJQWH'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"MARKTLOKATION": [2 items
{11 fields
"gueltigkeitszeitraum": {3 fields
"marktrollen": [2 items
{6 fields
{8 fields
"energieherkunft": [1 item
{1 field
{11 fields
"gueltigkeitszeitraum": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"energieherkunft": [1 item
{1 field
"BILANZIERUNG": [2 items
{9 fields
"gueltigkeitszeitraum": {3 fields
"lastprofile": [1 item
{2 fields
"temperaturarbeit": {2 fields
"detailsPrognosegrundlage": [1 item
{9 fields
"gueltigkeitszeitraum": {2 fields
"lastprofile": [1 item
{2 fields
"temperaturarbeit": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {14 fields
"absender": {5 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 3 |
| LF | LF | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 5 |
| NB | NB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 3 |
| NB | NB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 5 |
| MSB | MSB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 3 |
| MSB | MSB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 5 |
| ÜNB | ÜNB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 3 |
| ÜNB | ÜNB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 5 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response message/request data of the MaLo |
| AHB | UTILMD AHB electricity |
| Response to check identifier | 55628 |
| Decision tree | E_0409 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Master data change initiated by the NB (responsible) | MSB → NB | Response message on change |
| GPKE part 4 | Order placement for master data change to NB (responsible) | MSB → NB | Order placement of a change of master data from the MSB to NB |
Transaction and responses
Role of this check identifier: response message. Basis: the title or the action of the Prüfi table begins with “response message”. A response message carries no status field and is not a response in the sense of a decision tree.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Editorial — not derived from a source
The period ID of this response comes from the request. Condition [44] requires in STS DE9012: »Es ist die Zeitraum-ID vom DE1156 aus einem passenden SG6 RFF+Z49/Z53 … einzutragen« (the period ID from DE1156 of a matching SG6 RFF+Z49/Z53 of the request). In the JSON it is in transaktionsdaten.antwortStatusZeitraum → zeitraumId (SG4.IDE+24.STS+E01). Its value is the zeitraumId of the request's usage period that the response refers to: stammdaten.VERWENDUNGSZEITRAUM → zeitraumId (SG4.IDE+24.SG6.RFF+[Z49|Z53]).
Source: UTILMD AHB electricity (Knowledge Collection ahb/202604/UTILMDS and ahb/202610/UTILMDS), condition [44] at SG4 STS DE9012; segment mapping of the zeitraumId fields in the check identifier specifications · As of: 2026-09-23 · Applies to format version: 202604, 202610 · To be reviewed by: 2027-04-01
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 212 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 3 transactions for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.