Check identifier 55076 — Response to master data change
Check identifier 55076 · EDIFACT message type UTILMD · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55076 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00150 | Message recipient | — | X | — |
303900160 | MP-ID | — | X | [280] |
3055 900170 | GS1 | — | X | — |
3055 29300180 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400190 | Transaction | — | X | — |
740200200 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 15700210 | Validity, start date | — | X | — |
238000220 | Date or time or time span, value | — | X | [UB1] |
2379 30300230 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700240 | Transaction reason | — | X | — |
9013 E0300250 | Change | — | X | — |
9013 ZE300260 | Master data change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100270 | Status of the response | — | X | — |
901300280 | Code of the check step | — | X | — |
1131 S_009100290 | Electricity code list no. S_0091 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1600300 | Market location | — | X | — |
322500310 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2100320 | Tranche | — | X | — |
322500330 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700340 | Metering location | — | X | — |
322500350 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300360 | Check identifier | — | X | — |
1154 5507600370 | HKNR / Response to master data change | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00380 | Transaction reference number | — | X | — |
115400390 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0100400 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800410 | Market location | — | X | — |
115400420 | ID of the market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 ZB300430 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8900440 | LF | — | X | — |
113100450 | MP-ID | — | X | [611] |
| SG10.CCI | — | — | Must | — |
7059 Z1900460 | Balancing group | — | X | — |
703700470 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500480 | Structure | — | X | — |
7037 Z2100490 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100500 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z3400510 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3300520 | EEG market location without DV obligation | — | X | — |
7111 Z3400530 | KWKG market location without DV obligation | — | X | — |
7111 Z3500540 | other market location | — | X | — |
7111 Z3700550 | EEG market location with DV obligation | — | X | — |
7111 Z4600560 | KWKG market location with DV obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2200570 | Statutory category | — | X | — |
7037 Z9000580 | EEG- marketing type: default remuneration | — | X | [695] |
7037 Z9100590 | EEG- marketing type: market premium | — | X | [696] |
7037 Z9200600 | Marketing type without statutory remuneration | — | X | [696] |
7037 Z9400610 | KWKG remuneration | — | X | [695] |
| SG10.CCI | — | — | Must | — |
7059 Z2300620 | Country of production | — | X | — |
703700630 | Country of production | — | X | — |
1131 LAND00640 | EDI@Energy code list of European country codes | — | X | — |
3055 29300650 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0200660 | OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800670 | Market location | — | X | — |
115400680 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 500690 | Product identification | — | X | — |
714000700 | OBIS code of the market location | — | X | [314] |
7143 SRW00710 | OBIS code | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1500720 | Data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2000730 | Tranche | — | X | — |
115400740 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 1100750 | Distribution quantity | — | X | — |
606000760 | Quantity specification in % | — | X | [914] ∧ [930] ∧ [955] |
6411 P100770 | Percent | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300780 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8900790 | LF | — | X | — |
113100800 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900810 | Balancing group | — | X | — |
703700820 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3700830 | Basis for determining the tranche size | — | X | — |
7037 ZD100840 | Percentage-based | — | X | — |
7037 ZD200850 | Distribution factor based on reference carrier/ installed capacity | — | X | — |
7037 ZH100860 | Distribution across technical resources | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1700870 | OBIS data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2000880 | Tranche | — | X | — |
115400890 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 500900 | Product identification | — | X | — |
714000910 | OBIS code of the tranche | — | X | [269] |
7143 SRW00920 | OBIS code | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0300930 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900940 | Metering location | — | X | — |
115400950 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1400960 | Smart meter gateway | — | X | — |
115400970 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1300980 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ00990 | analog household meter (three-phase current) | — | X | — |
7111 WSZ01000 | analog alternating current meter | — | X | — |
7111 LAZ01010 | Load curve meter | — | X | — |
7111 MAZ01020 | Maximum demand meter | — | X | — |
7111 MME01030 | modern metering device according to MsbG | — | X | — |
7111 EHZ01040 | electronic household meter | — | X | — |
7111 IVA01050 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001060 | Device number | — | X | — |
711001070 | Device number | — | X | — |
| SG10.CAV | — | — | Must | [139] |
7111 ETZ01080 | Single tariff | — | X | — |
7111 ZTZ01090 | Two-tariff | — | X | — |
7111 NTZ01100 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ERZ01110 | Single-direction meter | — | X | — |
7111 ZRZ01120 | Bidirectional meter | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2001130 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [665] |
1153 MG01140 | Device number of the meter | — | X | [441] |
1153 Z1401150 | Smart meter gateway | — | X | — |
115401160 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901170 | Metering location | — | X | — |
115401180 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK01190 | Application reference number | — | X | — |
115401200 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501210 | Product identification | — | X | — |
714001220 | OBIS code of the metering device | — | X | [323] |
7143 SRW01230 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401240 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901250 | Annually | — | X | — |
7111 ZE801260 | Semi-annual | — | X | — |
7111 ZE901270 | Quarterly | — | X | — |
7111 ZB701280 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1101290 | Product | — | X | — |
7037 Z3301300 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001310 | Digits before the decimal point | — | X | — |
711001320 | Digits after the decimal point | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0401330 | Instrument transformer data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01340 | Device number of the meter | — | X | — |
115401350 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2501360 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3001370 | Device number | — | X | — |
711001380 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW01390 | Current transformer set | — | X | — |
7111 MPW01400 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW01410 | Block current transformer | — | X | — |
7111 MUW01420 | Voltage transformer set | — | X | — |
711001430 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 Z1301440 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7501450 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001460 | Device number | — | X | — |
711001470 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z1401480 | Control box | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1401490 | Smart meter gateway | — | X | — |
115401500 | Identification / number of the smart meter gateway | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801510 | Market location | — | X | — |
115401520 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 Z7601530 | Control box | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001540 | Device number | — | X | — |
711001550 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 VY01560 | other associated party | — | X | — |
303901570 | MP-ID | — | X | — |
3055 901580 | GS1 | — | X | — |
3055 29301590 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1801600 | Market location | — | X | — |
1153 Z2001610 | Tranche | — | X | — |
115401620 | ID of a market location / tranche | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 DP01630 | Supply address | — | X | — |
312401640 | Additional information for identification | — | — | — |
304201650 | Street and house number or PO box | — | — | S [166] M [212] |
316401660 | City | — | X | — |
325101670 | Postal code | — | X | — |
320701680 | Country name, code | — | X | — |
| UNT | — | — | Must | — |
007401690 | Number of segments in a message | — | X | — |
006201700 | Message reference number | — | X | — |
Conditions of this table
The free text of the 29 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [139] | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| [269] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3, that are required at the tranche must be stated |
| [280] | Only MP-ID from the electricity division |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [695] | Note: Use if the role LF is assigned to a company NB |
| [696] | Note: Use only if the role LF is not assigned to a company NB |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer ) is present, the segment must be specified exactly once |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
There is no role view for this check identifier: in this format version no process step of any market role carries it. A role statement would stand here without evidence.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to master data change |
| AHB | UTILMD AHB electricity |
| Transmission channel | MP |
This check identifier is used in 3 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 1 No. 2 | RB HKN-R → NB | Response to master data change |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 2 No. 2 | RB HKN-R → NB | Response to master data change |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 4 No. 2 | RB HKN-R → NB | Response to master data change |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 242 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.