Check identifier 55658 — Response message/request for data of MeLo
Check identifier 55658 · EDIFACT message type UTILMD · format version 202610
Data structure
| Structure (BO4E) | Description | Format | 55658 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| datenqualitaet 00010 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| messlokationsId * 00020 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00030 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| ablesekartenempfaenger | — | object | May | — |
| anrede 00040 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| gewerbekennzeichnung 00050 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | Must | — |
| name1 00060 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00070 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00080 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00090 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00100 | House number and supplement | string | Must | — |
| landescode 00110 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00120 | City | string | Must | — |
| ortsteil 00130 | District | string | Must | — |
| postfach 00140 | PO box | string | Must | — |
| postleitzahl 00150 | Postal code | string | Must | — |
| strasse 00160 | Street | string | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00170 | zeitraumId | integer | X | — |
| VERWENDUNGSZEITRAUM [ ] | — | object[] | May | — |
| datenqualitaet 00180 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| verwendungAb 00190 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00200 | verwendungBis | string (date-time) | X | — |
| zeitraumId 00210 | zeitraumId | integer | Must | — |
| ZAEHLER [ ] | — | object[] | May | — |
| datenqualitaet 00220 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| gateway 00230 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| tarifart 00240 | Specification regarding supported tariff types. | Enum Tarifart | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
SMART_METER | — | — | Must | — |
LEISTUNGSGEMESSEN | — | — | Must | — |
| zaehlerauspraegung 00250 | Specification regarding the direction of the meter. | Enum Zaehlerauspraegung | Must | — |
EINRICHTUNGSZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
| zaehlernummer 00260 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00270 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00280 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00290 | The number printed on the device, which is assigned by the MSB. | string | Should | [166] ∧ [215] |
| geraetetyp 00300 | List of possible billable device types | Enum Geraetetyp | Should | [166] ∧ [215] |
WECHSELSTROMZAEHLER | — | — | Should | — |
DREHSTROMZAEHLER | — | — | Should | — |
ZWEIRICHTUNGSZAEHLER | — | — | Should | — |
RLM_ZAEHLER | — | — | Should | — |
IMS_ZAEHLER | — | — | Should | — |
BALGENGASZAEHLER | — | — | Should | — |
MAXIMUMZAEHLER | — | — | Should | — |
MULTIPLEXANLAGE | — | — | Should | — |
PAUSCHALANLAGE | — | — | Should | — |
VERSTAERKERANLAGE | — | — | Should | — |
SUMMATIONSGERAET | — | — | Should | — |
IMPULSGEBER | — | — | Should | — |
EDL_21_ZAEHLERAUFSATZ | — | — | Should | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | Should | — |
MENGENUMWERTER | — | — | Should | — |
STROMWANDLER | — | — | Should | — |
SPANNUNGSWANDLER | — | — | Should | — |
DATENLOGGER | — | — | Should | — |
KOMMUNIKATIONSANSCHLUSS | — | — | Should | — |
MODEM | — | — | Should | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | Should | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | Should | — |
DREHKOLBENGASZAEHLER | — | — | Should | — |
TURBINENRADGASZAEHLER | — | — | Should | — |
ULTRASCHALLZAEHLER | — | — | Should | — |
WIRBELGASZAEHLER | — | — | Should | — |
MODERNE_MESSEINRICHTUNG | — | — | Should | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | Should | — |
STEUEREINRICHTUNG | — | — | Should | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | Should | — |
TARIFSCHALTGERAET | — | — | Should | — |
RUNDSTEUEREMPFAENGER | — | — | Should | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | Should | — |
MESSWANDLERSATZ_IMS_MME | — | — | Should | — |
KOMBIMESSWANDLER_IMS_MME | — | — | Should | — |
TARIFSCHALTGERAET_IMS_MME | — | — | Should | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | Should | — |
TEMPERATUR_KOMPENSATION | — | — | Should | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | Should | — |
SONSTIGES_GERAET | — | — | Should | — |
SMARTMETERGATEWAY | — | — | Should | — |
STEUERBOX | — | — | Should | — |
BLOCKSTROMWANDLER | — | — | Should | — |
KOMBIMESSWANDLER | — | — | Should | — |
MODEM_GSM | — | — | Should | — |
ETHERNET_KOM | — | — | Should | — |
PLC_COM | — | — | Should | — |
MODEM_FESTNETZ | — | — | Should | — |
DSL_KOM | — | — | Should | — |
LTE_KOM | — | — | Should | — |
DICHTEMENGENUMWERTER | — | — | Should | — |
TEMPERATURMENGENUMWERTER | — | — | Should | — |
ZUSTANDSMENGENUMWERTER | — | — | Should | — |
MESSDATENREGISTRIERGERAET | — | — | Should | — |
WANDLER | — | — | Should | — |
BEFESTIGUNGSEINRICHTUNG | — | — | Should | — |
| weitereGeraetenummern 00310 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 00320 | faktor | number (float) | Must | — |
| geraetemerkmal 00330 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00340 | zeitraumId | integer | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00350 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| konfiguration 00360 | Configuration (iMSys) of the meter register | string | X | — |
| nachkommastelle 00370 | nachkommastelle | integer | Must | — |
| obisKennzahl 00380 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00390 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00400 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00410 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00420 | Metering time period definition | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer 00430 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00440 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00450 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00460 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00470 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00480 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00490 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 00500 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00510 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00520 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| antwortStatusZeitraum [ ] | — | object[] | May | — |
| code 00530 | code | string | X | — |
| liste 00540 | liste | string | X | — |
| zeitraumId 00550 | zeitraumId | integer | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00560 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00570 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55658 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | [705] |
1001 Z8800080 | Request for data clearing | — | X | [706] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document-/ message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00130 | Document/message issuer or sender | — | X | — |
303900140 | MP-ID | — | X | — |
3055 900150 | GS1 | — | X | — |
3055 29300160 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00170 | Message recipient | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400210 | Transaction | — | X | — |
740200220 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700230 | Transaction reason | — | X | — |
9013 ZX700240 | Change data of the MeLo | — | X | — |
| SG4.STS | — | — | Must | [301] ∧ [557] ∧ [2011] |
9015 E0100250 | Status of the response | — | X | — |
901300260 | Code of the check step | — | X | — |
1131 E_041200270 | EBD no. E_0412 | — | X | — |
901200280 | Time period ID from the change notification of the responsible party | — | X | [914] ∧ [937] ∧ [44] |
| SG5.LOC | — | — | Must | — |
3227 Z1700290 | Metering location | — | X | — |
322500300 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300310 | Check identifier | — | X | — |
1154 5565800320 | GPKE / Response message / Request for data of the MeLo from LF to MSB | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00330 | Transaction reference number | — | X | — |
115400340 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z4700350 | Data available in the system | — | X | [5P0..n] |
1153 Z4800360 | Expected data | — | X | [2P0..n] |
1153 Z5400370 | No data available in the system | — | X | [4P0..n] |
1153 Z5500380 | No data expected | — | X | [2P0..n] |
115600390 | Time period ID | — | X | [914] ∧ [937] [127] ⊻ [128] |
| SG6.DTM | — | — | Must | [131] ⊻ [134] ⊻ [135] |
2005 Z2500400 | Data used from | — | X | — |
238000410 | Date or time or time span, value | — | X | [UB1] |
2379 30300420 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | [472] ⊻ [473] |
2005 Z2600430 | Data used until | — | X | — |
238000440 | Date or time or time span, value | — | X | [UB1] |
2379 30300450 | CCYYMMDDHHMMZZZ | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG600460 | Expected data of the metering location | — | X | [2P0..n] |
1229 ZG700470 | Data of the metering location existing in the system | — | X | [3P0..n] |
105000480 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7037 E0400490 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0300500 | Extra-high voltage | — | X | — |
7111 E0400510 | High voltage | — | X | — |
7111 E0500520 | Medium voltage | — | X | — |
7111 E0600530 | Low voltage | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZA300540 | Expected metering device data | — | X | [2P0..n] |
1229 ZA400550 | Metering device data available in the system | — | X | [3P0..n] |
105000560 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1400570 | Smart meter gateway | — | X | — |
115400580 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1300590 | Meter type | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 AHZ00600 | analog household meter (three-phase current) | — | X | — |
7111 WSZ00610 | analog alternating current meter | — | X | — |
7111 LAZ00620 | Load curve meter | — | X | — |
7111 MAZ00630 | Maximum demand meter | — | X | — |
7111 MME00640 | modern metering device according to MsbG | — | X | — |
7111 EHZ00650 | electronic household meter | — | X | — |
7111 IVA00660 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0100670 | EDL40 | — | X | [136] |
7110 Z0200680 | EDL21 | — | X | [136] |
7110 Z0300690 | other EHZ | — | X | [136] |
7110 Z0400700 | Standard | — | X | [346] |
7110 Z0500710 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Should | [8] |
7111 Z3000720 | Device number | — | X | — |
711000730 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 ETZ00740 | Single tariff | — | X | — |
7111 ZTZ00750 | Two-tariff | — | X | — |
7111 NTZ00760 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 ERZ00770 | Single-direction meter | — | X | — |
7111 ZRZ00780 | Bidirectional meter | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZA500790 | Expected OBIS data of the metering device | — | X | [2P0..n] |
1229 ZA600800 | OBIS data of the metering device available in the system | — | X | [3P0..n] |
105000810 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | [665] |
1153 MG00820 | Device number of the meter | — | X | [204] |
1153 Z1400830 | Smart meter gateway | — | X | — |
115400840 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK00850 | Application reference number | — | X | — |
115400860 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 500870 | Product identification | — | X | — |
714000880 | OBIS code of the metering device | — | X | [323] |
7143 SRW00890 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE400900 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD900910 | Annually | — | X | — |
7111 ZE800920 | Semi-annual | — | X | — |
7111 ZE900930 | Quarterly | — | X | — |
7111 ZB700940 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3900950 | Code of the metering time period definition | — | X | — |
703700960 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3800970 | Code of the metering time period register | — | X | — |
703700980 | Code of the metering time period register | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1100990 | Product | — | X | — |
7037 Z3301000 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001010 | Digits before the decimal point | — | X | — |
711001020 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6301030 | Local identifier for control purposes | — | X | — |
703601040 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZB901050 | Expected instrument transformer data | — | X | [2P0..n] |
1229 ZC001060 | Instrument transformer data available in the system | — | X | [3P0..n] |
105001070 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | — |
1153 MG01080 | Device number of the meter | — | X | — |
115401090 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2501100 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 Z3001110 | Device number | — | X | — |
711001120 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW01130 | Current transformer set | — | X | — |
7111 MPW01140 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW01150 | Block current transformer | — | X | — |
7111 MUW01160 | Voltage transformer set | — | X | — |
711001170 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 ZC301180 | Expected smart meter gateway | — | X | [2P0..n] |
1229 ZC401190 | Smart meter gateway available in the system | — | X | [3P0..n] |
105001200 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7037 Z7501210 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001220 | Device number | — | X | — |
711001230 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 Z4501240 | Expected name and address for the meter reading card | — | X | [2P0..1] |
3035 Z4601250 | Name and address for the meter reading card available in the system | — | X | [3P0..1] |
303601260 | Name | — | X | — |
3045 Z0101270 | Structure of person names | — | X | — |
3045 Z0201280 | Structure of the company name | — | X | — |
304201290 | Street and house number or PO box | — | X | — |
316401300 | City | — | X | — |
325101310 | Postal code | — | — | M [268] S [166] |
320701320 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601330 | Reference to time period ID | — | X | — |
115401340 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| UNT | — | — | Must | — |
007401350 | Number of segments in a message | — | X | — |
006201360 | Message reference number | — | X | — |
Conditions of this table
The free text of the 40 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [8] | If required for data clearing |
| [22] | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| [44] | The time period ID from DE1156 of a matching SG6 RFF+Z49/Z53 (usage period of the data: "valid data", "no data") from the request message from SG6 RFF+TN DE1154 ((reference transaction number (from request message)) must be entered |
| [127] | The value resulting from the number of repetitions of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) must be entered. This means: the first SG6 RFF+Z48/Z55 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [128] | The value resulting from the number of repetitions of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) must be entered. This means: the first SG6 RFF+Z47/Z54 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [131] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage peri od of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message dat e) at 0:00, or a day earlier than that at 0:00 German time |
| [134] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with the next lower time period ID in DE1156 |
| [135] | If this DTM+Z25 (use of the data from) is not in SG6 RFF+Z47/Z54 (usage perio d of the data: data present in the system/no data present in the system) with the time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of the data until) of the SG6 RFF+Z47/Z54 (usage perio d of the data: data present in the system/no data present in the system) with the next lower time period ID in DE1156 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [166] | If present |
| [204] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZA3/ZA4 (metering device data) with the same time period ID in the SG8 SEQ DE1050 and with identical quality in DE1229 of the SG8 SEQ, for the device number of a meter named in this RFF DE1154 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [301] | If BGM+E03 (change notification ) present |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [472] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) which is lower than in another SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) DE1156 (time period ID) |
| [473] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) which is lower than in another SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) DE1156 (time period ID) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [557] | Note: If the responsible party has sent more than eight usage periods, eight arbitrary usage periods are answered |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [705] | Note: If the action of a sequence diagram "Response message on change" is carried out |
| [706] | Note: If the action of a sequence diagram "Order placement of a change of master data..." is carried out with the aim of performing a data clearing |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [2011] | Segment group must be specified exactly once for each time period ID from DE1156 of the SG6 RFF+Z49 / Z53 (usage period of the data: "Valid data" / "No data") from the request message from SG6 RFF+TN DE1154 (reference transaction number (from request message)) |
| [5P0..n] | [315] If BGM+Z88 (data clearing) present [20 13 ] To be specified at least once , if no SG6 RFF+Z54 (Usage period of the data: no data present in the system) present |
| [2P0..n] | [301] If BGM+E03 (change notification) present [315] If BGM+Z88 (data clearing) present |
| [4P0..n] | [315] If BGM+Z88 (data clearing) present [20 14 ] To be specified at least once , if no SG6 RFF+Z47 (Usage period of the data: data present in the system) present |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [3P0..n] | [315] If BGM+Z88 (data clearing) present |
| [2P0..1] | [301] If BGM+E03 (change notification) present [315] If BGM+Z88 (data clearing) present |
| [3P0..1] | [315] If BGM+Z88 (data clearing) present |
Example message
UNA:+.? '
UNB+UNOC:3+9900496000001:500+9900496000002:500+{{date}}:{{time}}+M3C4Q0HK'
UNH+UNHM30L6XWP+UTILMD:D:11A:UN:S2.2'
BGM+E03+BGMM303C8J7'
DTM+137:202610021100?+00:303'
NAD+MS+9900496000001::293'
NAD+MR+9900496000002::293'
IDE+24+KBG27094210000000000929931413171000'
STS+7++ZX7'
STS+E01++A02:E_0412::1'
LOC+Z17+DE0032106765712000000000000001217'
RFF+Z13:55658'
RFF+TN:NNV1230'
RFF+Z48::1'
DTM+Z25:202412312300?+00:303'
SEQ+ZG6+1'
CCI+++E04'
CAV+E06'
SEQ+ZA3+1'
RFF+Z14:1ESY0012345678'
CCI+++E13'
CAV+MME:::Z04'
CAV+Z30:::1LOG0067003468'
CAV+ZTZ'
CAV+ERZ'
SEQ+ZA5+1'
RFF+Z14:1ESY0012345678'
RFF+AGK:34590456ujdfsdghdlktztwqq-053trg'
PIA+5+1-0?:1.8.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::7:3'
CCI+++Z63:::HT'
SEQ+ZB9+1'
RFF+MG:1LOG0067003468'
CCI+++Z25'
CAV+Z30:::1LOG0067003000'
CAV+MPW:::1'
SEQ+ZC3+1'
CCI+++Z75'
CAV+Z30:::1ESY0012345678'
NAD+Z45+++Max:Musterman::::Z01+Erfurter Str.:46+Weimar++99423+DE'
RFF+Z46:1'
UNT+43+UNHM30L6XWP'
UNZ+1+M3C4Q0HK'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [1 item
{5 fields
"MESSLOKATION": [1 item
{8 fields
"gueltigkeitszeitraum": {2 fields
"ablesekartenempfaenger": {7 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"ZAEHLER": [1 item
{13 fields
"gueltigkeitszeitraum": {2 fields
"zaehlwerke": [1 item
{6 fields
"geraete": [2 items
{2 fields
"geraeteeigenschaften": {1 field
{2 fields
"geraeteeigenschaften": {3 fields
"transaktionsdaten": {13 fields
"absender": {5 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [1 item
{3 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 3 |
| LF | LF | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
| NB | NB | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 3 |
| NB | NB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
| MSB | MSB | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 3 |
| MSB | MSB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
| MSB | WMSB | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 3 |
| MSB | WMSB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
| ÜNB | ÜNB | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 3 |
| ÜNB | ÜNB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response message/request data of the MeLo |
| AHB | UTILMD AHB electricity |
| Response to check identifier | 55653 |
| Decision tree | E_0412 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Master data change initiated by the MSB (responsible) | LF → MSB | Response message on change |
| GPKE part 4 | Order placement for master data change to MSB (responsible) | LF → MSB | Order placement of a change of master data from the LF to MSB |
Transaction and responses
Role of this check identifier: response message. Basis: the title or the action of the Prüfi table begins with “response message”. A response message carries no status field and is not a response in the sense of a decision tree.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Editorial — not derived from a source
The period ID of this response comes from the request. Condition [44] requires in STS DE9012: »Es ist die Zeitraum-ID vom DE1156 aus einem passenden SG6 RFF+Z49/Z53 … einzutragen« (the period ID from DE1156 of a matching SG6 RFF+Z49/Z53 of the request). In the JSON it is in transaktionsdaten.antwortStatusZeitraum → zeitraumId (SG4.IDE+24.STS+E01). Its value is the zeitraumId of the request's usage period that the response refers to: stammdaten.VERWENDUNGSZEITRAUM → zeitraumId (SG4.IDE+24.SG6.RFF+[Z49|Z53]).
Source: UTILMD AHB electricity (Knowledge Collection ahb/202604/UTILMDS and ahb/202610/UTILMDS), condition [44] at SG4 STS DE9012; segment mapping of the zeitraumId fields in the check identifier specifications · As of: 2026-09-23 · Applies to format version: 202604, 202610 · To be reviewed by: 2027-04-01
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 182 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.