Check identifier 55069 — Clearing list DZR
Check identifier 55069 · EDIFACT message type UTILMD · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55069 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0500070 | Clearing list | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | [502] |
2005 15700120 | Validity, start date | — | X | — |
238000130 | Date or time or time span, value | — | X | — |
2379 61000140 | CCYYMM | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AAV00150 | Number of the request | — | X | — |
115400160 | Reference, identification | — | X | [503] |
| SG2.NAD | — | — | Must | — |
3035 MS00170 | Document-/message sender or sender | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00210 | Information contact | — | X | — |
341200220 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800230 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00240 | Electronic mail | — | X | [1P0..1] |
3155 FX00250 | Fax number | — | X | [1P0..1] |
3155 TE00260 | Telephone | — | X | [1P0..1] |
3155 AJ00270 | further telephone | — | X | [1P0..1] |
3155 AL00280 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00290 | Message recipient | — | X | — |
303900300 | MP-ID | — | X | [280] |
3055 900310 | GS1 | — | X | — |
3055 29300320 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | [564] |
7495 Z0100330 | List | — | X | — |
740200340 | List number | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500350 | MaBiS metering point | — | X | — |
322500360 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300370 | Check identifier | — | X | — |
1154 5506900380 | MaBiS / clearing list DZR | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2200390 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AUU00400 | Reference to a time series | — | X | — |
115400410 | Version of the time series | — | X | — |
| SG4.IDE | — | — | Must | [505] ∧ [565] |
7495 2400420 | Transaction | — | X | — |
740200430 | Transaction number | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500440 | MaBiS metering point | — | X | — |
322500450 | Identifier | — | X | [951] |
| SG8.SEQ | — | — | Must | — |
1229 Z2200460 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AVE00470 | Reporting point | — | X | — |
115400480 | ID of the aggregated time series | — | X | [951] |
| SG8.RFF | — | — | Must | — |
1153 AUU00490 | Reference to a time series | — | X | — |
115400500 | Version of the time series | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500510 | Structure | — | X | — |
7037 Z2100520 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100530 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2500540 | Data status for the time series | — | X | — |
7037 Z0100550 | Billing data | — | X | — |
7037 Z0300560 | Billed data | — | X | — |
7037 Z0400570 | Billing data correction BKA | — | X | — |
7037 ZA500580 | Billed data correction BKA | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2300590 | Product data of the aggregated time series | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 500600 | Product identification | — | X | — |
714000610 | Product identification of the aggregated time series | — | X | — |
7143 SRW00620 | OBIS code | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 7900630 | Energy quantity totalled (total value, balance total) | — | X | — |
606000640 | Quantity specification | — | X | [902] |
6411 KWH00650 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 16300660 | Processing, start date/time | — | X | — |
238000670 | Date or time or time span, value | — | X | [UB1] |
2379 30300680 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 16400690 | Processing, end date/time | — | X | — |
238000700 | Date or time or time span, value | — | X | [UB1] |
2379 30300710 | CCYYMMDDHHMMZZZ | — | X | — |
| UNT | — | — | Must | — |
007400720 | Number of segments in a message | — | X | — |
006200730 | Message reference number | — | X | — |
Conditions of this table
The free text of the 17 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [280] | Only MP-ID from the electricity division |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [502] | Note: The reference month of the DZR or BAS is specified |
| [503] | Note: Indication of BGM DE1004 from the ORDERS |
| [505] | Note: One transaction required per assigned ID and per EEG transfer time series |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [902] | Format: Possible value: ≥ 0 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB, ÜNB and BIKO.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Request and transmission of the clearing list for the grid operator delta time series between BIKO and NB | MaBiS | Electricity | Step 3 |
| ÜNB | ÜNB | Request and transmission of the clearing list for the transmission system operator (TSO) delta time series between BIKO and ÜNB | MaBiS | Electricity | Step 3 |
| BIKO | BIKO | Request and transmission of the clearing list for the grid operator delta time series between BIKO and NB | MaBiS | Electricity | Step 3 |
| BIKO | BIKO | Request and transmission of the clearing list for the transmission system operator (TSO) delta time series between BIKO and ÜNB | MaBiS | Electricity | Step 3 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Clearing list DZR |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Request and transmission of the clearing list for the grid operator delta time series between BIKO and NB | BIKO → NB | Transmission of clearing list NB-DZR |
| MaBiS | Request and transmission of the clearing list for the transmission system operator (TSO) delta time series between BIKO and ÜNB | BIKO → ÜNB | Transmission of clearing list ÜNB-DZR |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 101 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.