Check identifier 55070 — Clearing list BAS
Check identifier 55070 · EDIFACT message type UTILMD · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55070 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0500070 | Clearing list | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | [502] |
2005 15700120 | Validity, start date | — | X | — |
238000130 | Date or time or time span, value | — | X | — |
2379 61000140 | CCYYMM | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AAV00150 | Number of the request | — | X | — |
115400160 | Reference, identification | — | X | [503] |
| SG2.NAD | — | — | Must | — |
3035 MS00170 | Document-/ message sender or sender | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00210 | Message recipient | — | X | — |
303900220 | MP-ID | — | X | [280] |
3055 900230 | GS1 | — | X | — |
3055 29300240 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | [564] |
7495 Z0100250 | List | — | X | — |
740200260 | List number | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500270 | MaBiS metering point | — | X | — |
322500280 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300290 | Check identifier | — | X | — |
1154 5507000300 | MaBiS / clearing list BAS | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2200310 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AUU00320 | Reference to a time series | — | X | — |
115400330 | Version of the time series | — | X | — |
| SG4.IDE | — | — | Must | [505] ∧ [565] |
7495 2400340 | Transaction | — | X | — |
740200350 | Transaction number | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500360 | MaBiS metering point | — | X | — |
322500370 | Identifier | — | X | [951] |
| SG8.SEQ | — | — | Must | — |
1229 Z2200380 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AVE00390 | Reporting point | — | X | — |
115400400 | ID of the aggregated time series | — | X | [951] |
| SG8.RFF | — | — | Must | — |
1153 AUU00410 | Reference to a time series | — | X | — |
115400420 | Version of the time series | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500430 | Structure | — | X | — |
7037 Z2100440 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100450 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2500460 | Data status for the time series | — | X | — |
7037 Z0100470 | Billing data | — | X | — |
7037 Z0300480 | Billed data | — | X | — |
7037 Z0400490 | Billing data correction BKA | — | X | — |
7037 ZA500500 | Billed data correction BKA | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2300510 | Product data of the aggregated time series | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 500520 | Product identification | — | X | — |
714000530 | Product identification of the aggregated time series | — | X | — |
7143 SRW00540 | OBIS code | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 7900550 | Energy quantity totalled (total value, balance total) | — | X | — |
606000560 | Quantity specification | — | X | [902] |
6411 KWH00570 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 16300580 | Processing, start date/time | — | X | — |
238000590 | Date or time or time span, value | — | X | [UB1] |
2379 30300600 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 16400610 | Processing, end date/time | — | X | — |
238000620 | Date or time or time span, value | — | X | [UB1] |
2379 30300630 | CCYYMMDDHHMMZZZ | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2400640 | Data of the transfer time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AUU00650 | Reference to a time series | — | X | — |
115400660 | Version of the time series | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500670 | Structure | — | X | — |
7037 Z2100680 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100690 | Code of the transfer time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2800700 | Balancing group "to" | — | X | — |
703700710 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2900720 | Balancing group "from" | — | X | — |
703700730 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2000740 | Balancing area | — | X | — |
703700750 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2500760 | Data status for the time series | — | X | — |
7037 Z0100770 | Billing data | — | X | — |
7037 Z0300780 | Billed data | — | X | — |
7037 Z0400790 | Billing data correction BKA | — | X | — |
7037 ZA500800 | Billed data correction BKA | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2500810 | Product data of the transfer time series | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 500820 | Product identification | — | X | — |
714000830 | Product identification of the transfer time series | — | X | — |
7143 Z0800840 | Medium | — | X | [380] |
7143 SRW00850 | OBIS code | — | X | [379] |
| SG9.QTY | — | — | Must | — |
6063 7900860 | Energy quantity totalled (total value, balance total) | — | X | — |
606000870 | Quantity specification | — | X | [902] |
6411 KWH00880 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 16300890 | Processing, start date/time | — | X | — |
238000900 | Date or time or time span, value | — | X | [UB1] |
2379 30300910 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 16400920 | Processing, end date/time | — | X | — |
238000930 | Date or time or time span, value | — | X | [UB1] |
2379 30300940 | CCYYMMDDHHMMZZZ | — | X | — |
| UNT | — | — | Must | — |
007400950 | Number of segments in a message | — | X | — |
006200960 | Message reference number | — | X | — |
Conditions of this table
The free text of the 13 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [280] | Only MP-ID from the electricity division |
| [379] | If SG10 CCI+15++Z21 (transfer time series type ) CAV+code for EEG transfer time series (excluding AU1) is present |
| [380] | If SG10 CCI+15++Z21 (transfer time series type ) CAV+AUS/AU1 is present |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [502] | Note: The reference month of the DZR or BAS is specified |
| [503] | Note: Indication of BGM DE1004 from the ORDERS |
| [505] | Note: One transaction required per assigned ID and per EEG transfer time series |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [902] | Format: Possible value: ≥ 0 |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are BIKO and BKV.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| BIKO | BIKO | Request and transmission of the clearing list for the net balancing group imbalance between BKV and BIKO | MaBiS | Electricity | Step 3 |
| BKV | BKV | Request and transmission of the clearing list for the net balancing group imbalance between BKV and BIKO | MaBiS | Electricity | Step 3 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Clearing list BAS |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Request and transmission of the clearing list for the net balancing group imbalance between BKV and BIKO | BIKO → BKV | Transmission of clearing list BAS |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 135 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.