Check identifier 55224 — Response to DZÜ list
Check identifier 55224 · EDIFACT message type UTILMD · format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55224 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
006800070 | General assignment reference | — | — | S [1] |
007000080 | Transmission sequence number | — | — | M [252] |
0073 C00090 | Start | — | — | M [2] |
0073 F00100 | End | — | — | S [3] |
| BGM | — | — | Must | — |
1001 Z3700110 | DZÜ list | — | X | — |
100400120 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700130 | Document/message date/time | — | X | — |
238000140 | Date or time or time span, value | — | X | [931] [494] |
2379 30300150 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 15700160 | Validity, start date | — | X | — |
238000170 | Date or time or time span, value | — | X | — |
2379 61000180 | CCYYMM | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00190 | Document-/ message sender or sender | — | X | — |
303900200 | MP-ID | — | X | — |
3055 900210 | GS1 | — | X | — |
3055 29300220 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00230 | Message recipient | — | X | — |
303900240 | MP-ID | — | X | [280] |
3055 900250 | GS1 | — | X | — |
3055 29300260 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | [564] |
7495 Z0100270 | List | — | X | — |
740200280 | List number | — | X | — |
| SG4.STS | — | — | Must | [238] |
9015 E0100290 | Status of the response | — | X | — |
901300300 | Code of the check step | — | X | — |
1131 E_007000310 | EBD no. E_0070 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500320 | MaBiS metering point | — | X | — |
322500330 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300340 | Check identifier | — | X | — |
1154 5522400350 | MaBiS / response to DZÜ list | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00360 | Transaction reference number | — | X | — |
115400370 | Reference, identification | — | X | [655] |
| SG8.SEQ | — | — | Must | — |
1229 Z2200380 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AUU00390 | Reference to a time series | — | X | — |
115400400 | Version of the time series | — | X | — |
| SG4.IDE | — | — | Must | [565] |
7495 2400410 | Transaction | — | X | — |
740200420 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 E0100430 | Status of the response | — | X | — |
901300440 | Code of the check step | — | X | — |
1131 E_007000450 | EBD no. E_0070 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1600460 | Market location | — | X | — |
322500470 | ID of the market location | — | X | [950] [528] |
| SG5.LOC | — | — | Must | — |
3227 Z2100480 | Tranche | — | X | — |
322500490 | ID of the tranche | — | X | [950] [528] |
| SG6.RFF | — | — | Must | — |
1153 TN00500 | Transaction reference number | — | X | — |
115400510 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z7200520 | Data status of the NB | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3100530 | Estimated annual quantity total | — | X | — |
606000540 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00550 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4500560 | Energy quantity to be balanced | — | X | — |
606000570 | Quantity specification | — | X | — |
6411 KWH00580 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15800590 | Start of balancing | — | X | — |
238000600 | Date or time or time span, value | — | X | [UB1] ∧ [454] |
2379 30300610 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15900620 | End of balancing | — | X | — |
238000630 | Date or time or time span, value | — | X | [UB1] ∧ [455] |
2379 30300640 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900650 | Balancing group | — | X | — |
703700660 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2000670 | Balancing area | — | X | — |
703700680 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500690 | Structure | — | X | — |
7037 Z2100700 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100710 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0200720 | Standard load profile | — | X | — |
7059 Z0400730 | Standard feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711100740 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 600750 | Responsible party | — | X | — |
7037 ZA800760 | NB | — | X | — |
7037 ZA900770 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZG300780 | Location in regular operation | — | X | — |
7111 ZG400790 | Location outside regular operation (decommissioning) | — | X | — |
| UNT | — | — | Must | — |
007400800 | Number of segments in a message | — | X | — |
006200810 | Message reference number | — | X | — |
Conditions of this table
The free text of the 19 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [1] | If a split is present |
| [2] | If UNH DE0070 (transmission sequence number) with 1 is present |
| [3] | In the case of splitting, in the message with the highest transmission sequence number |
| [238] | If SG4 IDE+24 (transaction) is not present |
| [252] | If DE0068 is present |
| [280] | Only MP-ID from the electricity division |
| [454] | The balancing start date must be earlier than the balancing end date in the SG8 “Data status of the ÜNB”, SG 9 energy quantity DZÜ share |
| [455] | The balancing end date must be later than the balancing start date in the SG8 “Data status of the ÜNB” , SG 9 energy quantity DZÜ share |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [528] | Note: The date/dates from the request must be used |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [655] | Note: The list number from the DZÜ list must be used |
| [902] | Format: Possible value: ≥ 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB, ÜNB and BIKO.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Transmission of validation notification of the delta time series transfer from NB via BIKO to ÜNB | MaBiS | Electricity | Step 2 |
| ÜNB | ÜNB | Transmission of validation notification of the delta time series transfer from NB via BIKO to ÜNB | MaBiS | Electricity | Step 2 |
| BIKO | BIKO | Transmission of validation notification of the delta time series transfer from NB via BIKO to ÜNB | MaBiS | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to DZÜ list |
| AHB | UTILMD AHB electricity |
| Decision tree | E_0070 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the validation notification for the delta time series transfer from NB via BIKO to ÜNB | NB → ÜNB | Correction of DZÜ list |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 113 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.