Check identifier 55204 — Response to ZP activation
Check identifier 55204 · EDIFACT message type UTILMD · format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55204 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0700070 | Activation/ deactivation of MaBiS-ZP | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | [280] |
3055 900260 | GS1 | — | X | — |
3055 29300270 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 15800300 | Start of balancing | — | X | — |
238000310 | Date or time or time span, value | — | X | [UB1] |
2379 30300320 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100330 | Status of the response | — | X | — |
901300340 | Code of the check step | — | X | — |
1131 E_007100350 | EBD no. E_0071 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500360 | MaBiS metering point | — | X | — |
322500370 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300380 | Check identifier | — | X | — |
1154 5520400390 | Redispatch / Response to activation ZP | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00400 | Transaction reference number | — | X | — |
115400410 | Transaction number | — | X | — |
| UNT | — | — | Must | — |
007400420 | Number of segments in a message | — | X | — |
006200430 | Message reference number | — | X | — |
Conditions of this table
The free text of the 12 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| [280] | Only MP-ID from the electricity division |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB, BIKO and BKV.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | ANB | Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF) | MaBiS | Electricity | Step 2 |
| BIKO | BIKO | Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF) | MaBiS | Electricity | Step 2 |
| BKV | BKV-LF | Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF) | MaBiS | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to activation of ZP |
| AHB | UTILMD AHB electricity |
| Decision tree | E_0071 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF) | BIKO → NB (ANB) | Response |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 57 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.