Check identifier 55168 — Commitment request / demand
Check identifier 55168 · EDIFACT message type UTILMD · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 55168 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] | — | object[] | May | — |
| abwicklungsmodell 00010 | Processing model | Enum Abwicklungsmodell | Must | — |
MODELL_1_BILANZIERUNG_AN_MARKTLOKATION | — | — | Must | — |
MODELL_2_BILANZIERUNG_IM_BILANZIERUNGSGEBIET | — | — | Must | — |
| aggregationsverantwortung 00020 | Aggregation responsibility | Enum Aggregationsverantwortung | X | — |
UENB | — | — | X | — |
VNB | — | — | X | — |
| detailsPrognosegrundlage 00030 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| marktlokationsId 00040 | Which market location these balancing data apply to | string | X | — |
| prognosegrundlage 00050 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00080 | Designation of the profile | string | Must | — |
| einspeisung 00090 | Feed-in indicator | boolean | Must | — |
| profilart 00100 | Profile category | Enum Profilart | Must | — |
ART_STANDARDLASTPROFIL | — | — | Must | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | Must | — |
ART_LASTPROFIL | — | — | Must | — |
| referenzprofilbezeichnung 00110 | Designation of the reference profile | string | Must | — |
| verfahren 00120 | Profiling method | Enum Profilverfahren | Must | — |
SYNTHETISCH | — | — | Must | — |
ANALYTISCH | — | — | Must | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00130 | dienstanbieter | string | Must | — |
| herausgeber 00140 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00150 | klimazone | string | Must | — |
| temperaturmessstelle 00160 | temperaturmessstelle | string | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00170 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00180 | Value | number (float) | Must | — |
| ENERGIELIEFERVERTRAG [ ] | — | object[] | May | — |
| lokationsId 00190 | lokationsId | string | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00200 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 00210 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00220 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00230 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00240 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00250 | House number and supplement | string | X | — |
| landescode 00260 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00270 | City | string | X | — |
| ortsteil 00280 | District | string | X | — |
| postfach 00290 | PO box | string | X | — |
| postleitzahl 00300 | Postal code | string | X | — |
| strasse 00310 | Street | string | X | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00320 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 00330 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 00340 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00350 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00360 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00370 | name4 | string | X | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00380 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00390 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00400 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00410 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00420 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00430 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00440 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00450 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00460 | lokationsbuendelNummer | integer | X | — |
| objectcode 00470 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| energierichtung 00480 | Indicates whether energy is fed in or drawn (fed out). | Enum Energierichtung | X | — |
AUSSP | — | — | X | — |
EINSP | — | — | X | — |
| marktlokationsId * 00490 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00500 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00510 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00520 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00530 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00540 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00550 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00560 | weiterverpflichtet | boolean | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00570 | messprodukt | string | X | — |
| obisKennzahl 00580 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszweckLF 00590 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 00600 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| verwendungszweckUENB 00610 | Codes according to the code list of the purposes of use Purpose of use ÜNB | string | X | — |
| wertegranularitaet 00620 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00630 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00640 | Metering time period definition | string | X | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| betriebszustand 00650 | Operating state | Enum Betriebszustand | X | — |
GESPERRT_NICHT_ENTSPERREN | — | — | X | — |
GESPERRT | — | — | X | — |
REGELBETRIEB | — | — | X | — |
AUSSERHALB_REGELBETRIEB | — | — | X | — |
| datenqualitaet 00660 | Data quality | Enum Datenqualitaet | X | — |
ERWARTETE_DATEN | — | — | X | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
INFORMATIVE_DATEN | — | — | X | — |
GUELTIGE_DATEN | — | — | X | — |
KEINE_DATEN | — | — | X | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | X | — |
KEINE_DATEN_ERWARTET | — | — | X | — |
DIFFERENZ_DATEN | — | — | X | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | X | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
| messlokationsId * 00670 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00680 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| referenzMarktlokationsId 00690 | referenzMarktlokationsId | string | X | — |
| verwendungsumfang 00700 | Scope of use | Enum Verwendungsumfang | X | — |
MESSLOKATION_PROZESSUAL_BEHANDELT | — | — | X | — |
MESSLOKATION_LOKATIONSBUENDEL | — | — | X | — |
| ablesekartenempfaenger * | — | object | Must | — |
| anrede 00710 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00720 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00730 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00740 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00750 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00760 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00770 | House number and supplement | string | X | — |
| landescode 00780 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00790 | City | string | X | — |
| ortsteil 00800 | District | string | X | — |
| postfach 00810 | PO box | string | X | — |
| postleitzahl 00820 | Postal code | string | X | — |
| strasse 00830 | Street | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00840 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00850 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00860 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00870 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00880 | House number and supplement | string | X | — |
| landescode 00890 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00900 | City | string | X | — |
| ortsteil 00910 | District | string | X | — |
| postfach 00920 | PO box | string | X | — |
| postleitzahl 00930 | Postal code | string | X | — |
| strasse 00940 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00950 | Address supplement 1 | string | X | — |
| zusatz2 00960 | Address supplement 2 | string | X | — |
| zusatz3 00970 | Address supplement 3 | string | X | — |
| zusatz4 00980 | Address supplement 4 | string | X | — |
| zusatz5 00990 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01000 | messprodukt | string | X | — |
| notwendigkeitZweiteMessung 01010 | Necessity of second measurement | Enum NotwendigkeitZweiteMessung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| werteuebermittlungVerwendungszweck 01020 | Purpose of use for value transmission | Enum WerteuebermittlungVerwendungszweck | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| zaehlzeiten | — | object | May | — |
| zaehlzeitDefinition 01030 | Metering time period definition | string | Must | — |
| MESSSTELLENBETRIEBSVERTRAG [ ] * | — | object[] | Must | — |
| lokationsId * 01040 | lokationsId | string | X | — |
| lokationsTyp * 01050 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | X | — |
MALO | — | — | X | — |
MELO | — | — | X | — |
NELO | — | — | X | — |
TECHNISCHE_RESSOURCE | — | — | X | — |
STEUERBARE_RESSOURCE | — | — | X | — |
TRANCHE | — | — | X | — |
MABIS_ZAEHLPUNKT | — | — | X | — |
| korrespondenzpartner * | — | object | Must | — |
| anrede 01060 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 * 01070 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01080 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01090 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01100 | name4 | string | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 01110 | Email address | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 01120 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 01130 | rufnummer | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 01140 | House number and supplement | string | X | — |
| landescode 01150 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 01160 | City | string | X | — |
| ortsteil 01170 | District | string | X | — |
| postfach 01180 | PO box | string | X | — |
| postleitzahl 01190 | Postal code | string | X | — |
| strasse 01200 | Street | string | X | — |
| vertragskonditionen | — | object | May | — |
| geplanteTurnusablesung | — | object | May | — |
| ableseZeitraum 01210 | ableseZeitraum | string | X | — |
| vertragspartner2 [ ] * | — | object[] | Must | — |
| anrede 01220 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 01230 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 * 01240 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01250 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01260 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01270 | name4 | string | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 01280 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 01290 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 01300 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| produktdatenRelevanteRolle 01310 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| steuerkanal 01320 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01330 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01340 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01350 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01360 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01370 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| keinProdukt 01380 | CCI+11++ZF6: no product assigned | boolean | X | — |
| obisKennzahl 01390 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszweckLF 01400 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 01410 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| NETZNUTZUNGSVERTRAG [ ] | — | object[] | May | — |
| lokationsId 01420 | lokationsId | string | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 01430 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 01440 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01450 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01460 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01470 | name4 | string | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 01480 | Email address | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 01490 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 01500 | rufnummer | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 01510 | House number and supplement | string | X | — |
| landescode 01520 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 01530 | City | string | X | — |
| ortsteil 01540 | District | string | X | — |
| postfach 01550 | PO box | string | X | — |
| postleitzahl 01560 | Postal code | string | X | — |
| strasse 01570 | Street | string | X | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 01580 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 01590 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 01600 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01610 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01620 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01630 | name4 | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| keinKonfigurationsprodukt 01640 | keinKonfigurationsprodukt | boolean | X | — |
| konfigurationsprodukt 01650 | konfigurationsprodukt | string | X | — |
| produktdatenRelevanteRolle 01660 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| ressourcenId 01670 | ressourcenId | string | X | — |
| steuerkanal 01680 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01690 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01700 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01710 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01720 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01730 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 01740 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 01750 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 01760 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 01770 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| enwg 01780 | enwg | boolean | Must | — |
| erzeugungsart 01790 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| referenzNetzlokation 01800 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 01810 | referenzSteuerbareRessource | string | X | — |
| referenzTranche 01820 | referenzTranche | string | X | — |
| ressourcenId 01830 | ressourcenId | string | X | — |
| speicherart 01840 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 01850 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 01860 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | — |
| waermenutzung 01870 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| nennleistung | — | object | May | — |
| abgabe 01880 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 01890 | Recording of the rated power | number (float) | X | — |
| TRANCHE [ ] | — | object[] | May | — |
| bildungTranchengroesse 01900 | BildungTranchengroesse | Enum BildungTranchengroesse | X | — |
PROZENTUAL | — | — | X | — |
AUFTEILUNGSFAKTOR | — | — | X | — |
AUFTEILUNG_TECHNISCHE_RESSOURCEN | — | — | X | — |
BERECHNUNGSFORMEL | — | — | X | — |
| referenzMarktlokationsId 01910 | referenzMarktlokationsId | string | X | — |
| tranchenId 01920 | tranchenId | string | X | — |
| aufteilungsmenge | — | object | May | — |
| einheit 01930 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 01940 | Value | number (float) | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01950 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 01960 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01970 | messprodukt | string | X | — |
| verwendungszweckLF 01980 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 01990 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| verwendungszweckUENB 02000 | Codes according to the code list of the purposes of use Purpose of use ÜNB | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 02010 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| fernschaltung 02020 | Remote switching | Enum Fernschaltung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| gateway 02030 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| marktlokationsId 02040 | marktlokationsId | string | X | — |
| messlokationsId 02050 | messlokationsId | string | X | — |
| messwerterfassung 02060 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| tarifart 02070 | Specification regarding supported tariff types. | Enum Tarifart | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
SMART_METER | — | — | Must | — |
LEISTUNGSGEMESSEN | — | — | Must | — |
| zaehlerauspraegung 02080 | Specification regarding the direction of the meter. | Enum Zaehlerauspraegung | Must | — |
EINRICHTUNGSZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
| zaehlernummer 02090 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 02100 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 02110 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 02120 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraetetyp 02130 | List of possible billable device types | Enum Geraetetyp | X | — |
WECHSELSTROMZAEHLER | — | — | X | — |
DREHSTROMZAEHLER | — | — | X | — |
ZWEIRICHTUNGSZAEHLER | — | — | X | — |
RLM_ZAEHLER | — | — | X | — |
IMS_ZAEHLER | — | — | X | — |
BALGENGASZAEHLER | — | — | X | — |
MAXIMUMZAEHLER | — | — | X | — |
MULTIPLEXANLAGE | — | — | X | — |
PAUSCHALANLAGE | — | — | X | — |
VERSTAERKERANLAGE | — | — | X | — |
SUMMATIONSGERAET | — | — | X | — |
IMPULSGEBER | — | — | X | — |
EDL_21_ZAEHLERAUFSATZ | — | — | X | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | X | — |
MENGENUMWERTER | — | — | X | — |
STROMWANDLER | — | — | X | — |
SPANNUNGSWANDLER | — | — | X | — |
DATENLOGGER | — | — | X | — |
KOMMUNIKATIONSANSCHLUSS | — | — | X | — |
MODEM | — | — | X | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
DREHKOLBENGASZAEHLER | — | — | X | — |
TURBINENRADGASZAEHLER | — | — | X | — |
ULTRASCHALLZAEHLER | — | — | X | — |
WIRBELGASZAEHLER | — | — | X | — |
MODERNE_MESSEINRICHTUNG | — | — | X | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | X | — |
STEUEREINRICHTUNG | — | — | X | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | X | — |
TARIFSCHALTGERAET | — | — | X | — |
RUNDSTEUEREMPFAENGER | — | — | X | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | X | — |
MESSWANDLERSATZ_IMS_MME | — | — | X | — |
KOMBIMESSWANDLER_IMS_MME | — | — | X | — |
TARIFSCHALTGERAET_IMS_MME | — | — | X | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | X | — |
TEMPERATUR_KOMPENSATION | — | — | X | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | X | — |
SONSTIGES_GERAET | — | — | X | — |
SMARTMETERGATEWAY | — | — | X | — |
STEUERBOX | — | — | X | — |
BLOCKSTROMWANDLER | — | — | X | — |
KOMBIMESSWANDLER | — | — | X | — |
MODEM_GSM | — | — | X | — |
ETHERNET_KOM | — | — | X | — |
PLC_COM | — | — | X | — |
MODEM_FESTNETZ | — | — | X | — |
DSL_KOM | — | — | X | — |
LTE_KOM | — | — | X | — |
DICHTEMENGENUMWERTER | — | — | X | — |
TEMPERATURMENGENUMWERTER | — | — | X | — |
ZUSTANDSMENGENUMWERTER | — | — | X | — |
MESSDATENREGISTRIERGERAET | — | — | X | — |
WANDLER | — | — | X | — |
BEFESTIGUNGSEINRICHTUNG | — | — | X | — |
| weitereGeraetenummern 02140 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 02150 | faktor | number (float) | Must | — |
| geraetemerkmal 02160 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 02170 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| konfiguration 02180 | Configuration (iMSys) of the meter register | string | X | — |
| nachkommastelle 02190 | nachkommastelle | integer | Must | — |
| obisKennzahl 02200 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 02210 | vorkommastelle | integer | Must | — |
| wertegranularitaet 02220 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| datumleistungsbeginn * 02230 | Date of the planned start of service / DTM+76 | string (date-time) | X | — |
| dokumentennummer * 02240 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 02250 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 02260 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 02270 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 02280 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 02290 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 02300 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 02310 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02320 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 02330 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02340 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55168 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | [637] |
1001 Z4000080 | Request | — | X | [638] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document/message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00130 | Document-/ message sender or sender | — | X | — |
303900140 | MP-ID | — | X | — |
3055 900150 | GS1 | — | X | — |
3055 29300160 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00170 | Message recipient | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400210 | Transaction | — | X | — |
740200220 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 7600230 | Delivery date/time, scheduled | — | X | — |
238000240 | Date or time or time span, value | — | X | [UB1] |
2379 30300250 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700260 | Transaction reason | — | X | — |
9013 E0100270 | Move-in/move-out (relocation) | — | X | — |
9013 E0200280 | Move-in to creation | — | X | — |
9013 E0300290 | Change | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800300 | Grid location | — | X | — |
322500310 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600320 | Market location | — | X | — |
322500330 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2200340 | Dormant market location | — | X | — |
322500350 | ID of the dormant market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000360 | Technical resource | — | X | — |
322500370 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900380 | Controllable resource | — | X | — |
322500390 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z2100400 | Tranche | — | X | — |
322500410 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700420 | Metering location | — | X | — |
322500430 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300440 | Check identifier | — | X | — |
1154 5516800450 | WiM electricity / commitment request / demand | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z5000460 | Scheduling data of the market location | — | X | — |
115400470 | ID of the market location / reference to time period ID | — | X | [950] |
| SG6.DTM | — | — | Must | [78] ∧ [234] ∧ [618] |
2005 75200480 | Periodic meter reading | — | X | — |
238000490 | Date or time or time span, value | — | X | — |
2379 10400500 | MMWW-MMWW | — | X | — |
2379 10600510 | MMDD | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z7800520 | Reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100530 | Location bundle structure | — | X | — |
1153 Z3900540 | No standardized location bundle structure available | — | X | — |
115400550 | ID of the location bundle structure | — | X | [333] |
115600560 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 Z5800570 | Assignment of the location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200580 | Grid location | — | X | — |
1153 Z1800590 | Market location | — | X | — |
1153 Z1900600 | Metering location | — | X | — |
1153 Z3700610 | Technical resource | — | X | — |
115400620 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2312] |
1153 Z3300630 | Object code of the location in the location bundle structure | — | X | — |
115400640 | Object code | — | X | — |
115600650 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400660 | upstream metering location | — | X | — |
1153 Z3500670 | upstream grid location | — | X | — |
115400680 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600690 | assigned market location | — | X | — |
115400700 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 Z5100710 | Data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200720 | Grid location | — | X | — |
115400730 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900740 | Control channel | — | X | — |
7037 ZF200750 | No control channel available | — | X | — |
7037 ZF300760 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300770 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100780 | MSB | — | X | — |
113100790 | MP-ID | — | X | — |
7110 Z3900800 | Default metering point operator | — | X | — |
7110 Z4000810 | Competitive metering point operator | — | X | — |
7110 Z4100820 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5700830 | OBIS data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200840 | Grid location | — | X | — |
115400850 | ID of the grid location | — | X | [960] |
| SG8.PIA | — | — | Must | [159] |
4347 500860 | Product identification | — | X | — |
714000870 | OBIS code of the grid location | — | X | — |
7143 SRW00880 | OBIS code | — | X | — |
714300890 | Purpose of use NB | — | X | [353] |
1131 Z1600900 | EDI@Energy code list of purposes of use | — | X | — |
714300910 | Purpose of use LF | — | X | [354] |
1131 Z1600920 | EDI@Energy code list of purposes of use | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1100930 | Product | — | X | — |
7037 ZF600940 | No product assigned | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6000950 | Product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200960 | Grid location | — | X | — |
115400970 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 500980 | Product identification | — | X | — |
714000990 | Configuration product code | — | X | [412] |
7143 Z1201000 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5301010 | Code of the power curve definition | — | X | — |
703701020 | Code of the power curve definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301030 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8801040 | NB | — | X | — |
7111 Z8901050 | LF | — | X | — |
113101060 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA701070 | LF | — | X | [1P0..1] |
7037 ZA801080 | NB | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0101090 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801100 | Market location | — | X | — |
115401110 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 26501120 | Estimated annual quantity total/ annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0801130 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606001140 | Quantity | — | X | [902] |
6411 Z1601150 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH01160 | Kilowatt hour | — | X | [104] |
| SG9.QTY | — | — | Must | — |
6063 3101170 | Estimated annual quantity total | — | X | — |
606001180 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH01190 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3001200 | Delivery direction | — | X | — |
7037 Z0601210 | Generation | — | X | — |
7037 Z0701220 | Consumption | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301230 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | [78] ∧ [221] |
7111 Z8901240 | LF | — | X | — |
113101250 | MP-ID | — | X | [611] |
| SG10.CAV | — | — | Must | — |
7111 Z9001260 | ÜNB | — | X | — |
113101270 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101280 | MSB | — | X | — |
113101290 | MP-ID | — | X | [621] |
7110 Z3901300 | Default metering point operator | — | X | — |
7110 Z4001310 | Competitive metering point operator | — | X | — |
7110 Z4101320 | Fallback metering point operator | — | X | — |
7110 Z1901330 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001340 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301350 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301360 | Extra-high voltage | — | X | — |
7111 E0401370 | High voltage | — | X | — |
7111 E0501380 | Medium voltage | — | X | — |
7111 E0601390 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301400 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201410 | iMS | — | X | — |
7111 Z5301420 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 601430 | Responsible party | — | X | — |
7037 ZA801440 | NB | — | X | — |
7037 ZA901450 | ÜNB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001460 | Forecast based on values | — | X | — |
7037 ZA601470 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [210] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0201480 | SLP/SEP | — | X | [1P0..1] |
7111 E1401490 | TLP/TEP | — | X | [1P0..1] |
7111 Z3601500 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3401510 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3301520 | EEG market location without DV obligation | — | X | — |
7111 Z3401530 | KWKG market location without DV obligation | — | X | — |
7111 Z3501540 | other market location | — | X | — |
7111 Z3701550 | EEG market location with DV obligation | — | X | — |
7111 Z4601560 | KWKG market location with DV obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 ZA201570 | Processing model | — | X | — |
7037 ZE901580 | Model 1 "Balancing at the market location" | — | X | — |
7037 ZF001590 | Model 2 "Balancing in the balancing area (BG) of the LPB" | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2701600 | Required metering product of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801610 | Market location | — | X | — |
115401620 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501630 | Product identification | — | X | — |
714001640 | Metering product code | — | X | [425] |
7143 Z1101650 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901660 | Code of the metering time period definition | — | X | — |
7059 Z4101670 | No metering time period required for metering product | — | X | [417] |
703701680 | Code of the metering time period definition | — | X | [438] |
| SG10.CCI | — | — | Must | — |
7037 ZA801690 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401700 | Grid usage settlement | — | X | [19P1..1] ⊻ [20P1..1] ⊻ [22P1..1] ⊻ [26P1..1] |
7111 Z8501710 | Balancing group settlemen t | — | X | [21P0..1] ⊻ [22P0..1] ⊻ [23P0..1] ⊻ [24P0..1] |
7111 Z8601720 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z9201730 | Transmission to the HKNR | — | X | [23P1..1] ⊻ [24P1..1] |
7111 ZE101740 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA701750 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401760 | Grid usage settlement | — | X | [19P0..1] ⊻ [20P0..1] ⊻ [22P0..1] ⊻ [26P0..1] |
7111 Z8501770 | Balancing group settlemen t | — | X | [21P1..1] ⊻ [22P1..1] ⊻ [23P1..1] ⊻ [24P1..1] |
7111 Z8601780 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z4701790 | End customer billing | — | X | [19P1..1] ⊻ [20P0..1] ⊻ [22P1..1] ⊻ [24P1..1] ⊻ [25P1..1] ⊻ [26P0..1] ⊻ [27P1..1] |
7111 ZE101800 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA901810 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8501820 | Balancing group settlemen t | — | X | [1P0..1] |
7111 ZB501830 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0201840 | OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801850 | Market location | — | X | — |
115401860 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501870 | Product identification | — | X | — |
714001880 | OBIS code of the market location | — | X | [314] |
7143 SRW01890 | OBIS code | — | X | — |
714301900 | Purpose of use NB | — | X | [381] |
1131 Z1601910 | EDI@Energy code list of purposes of use | — | X | — |
714301920 | Purpose of use LF | — | X | [382] |
1131 Z1601930 | EDI@Energy code list of purposes of use | — | X | — |
714301940 | Purpose of use ÜNB | — | X | [383] |
1131 Z1601950 | EDI@Energy code list of purposes of use | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401960 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901970 | Annually | — | X | — |
7111 ZE801980 | Semi-annual | — | X | — |
7111 ZE901990 | Quarterly | — | X | — |
7111 ZB702000 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3902010 | Code of the metering time period definition | — | X | — |
703702020 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3802030 | Code of the metering time period register | — | X | — |
703702040 | Code of the metering time period register | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1502050 | Data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002060 | Tranche | — | X | — |
115402070 | ID of the tranche | — | X | [950] |
| SG8.RFF | — | — | Must | — |
1153 Z1602080 | assigned market location | — | X | — |
115402090 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 1102100 | Distribution quantity | — | X | — |
606002110 | Quantity specification in % | — | X | [914] ∧ [930] ∧ [955] |
6411 P102120 | Percent | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302130 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8902140 | LF | — | X | — |
113102150 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3702160 | Basis for determining the tranche size | — | X | — |
7037 ZD102170 | Percentage-based | — | X | — |
7037 ZD202180 | Distribution factor based on reference carrier/ installed capacity | — | X | — |
7037 ZH102190 | Distribution across technical resources | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1602200 | Required product of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002210 | Tranche | — | X | — |
115402220 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 502230 | Product identification | — | X | — |
714002240 | Metering product code | — | X | [426] |
7143 Z1102250 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA802260 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502270 | Balancing group settlemen t | — | X | [1P0..1] |
7111 Z9202280 | Transmission to the HKNR | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA702290 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502300 | Balancing group settlemen t | — | X | [1P1..1] |
7111 Z4702310 | End customer billing | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA902320 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502330 | Balancing group settlemen t | — | X | [1P0..1] |
7111 ZB502340 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG10.CAV | — | — | Must | [446] |
| SG8.SEQ | — | — | Must | — |
1229 Z5202350 | Data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3702360 | Technical resource | — | X | — |
115402370 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3802380 | Controllable resource | — | X | — |
115402390 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3202400 | Grid location | — | X | — |
115402410 | ID of the grid location | — | X | [960] |
| SG8.RFF | — | — | Should | [166] ∧ [447] ∧ [701] |
1153 Z2002420 | Tranche | — | X | — |
115402430 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z4302440 | Rated power (input) | — | X | — |
606002450 | Quantity | — | X | — |
6411 KWT02460 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4402470 | Rated power (output) | — | X | — |
606002480 | Quantity | — | X | — |
6411 KWT02490 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4202500 | Storage capacity | — | X | — |
606002510 | Quantity | — | X | — |
6411 KWH02520 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1702530 | Type of electricity consumption | — | X | — |
7059 Z5002540 | Type of electricity generation | — | X | — |
7059 Z5602550 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6402560 | Power/light | — | X | [1P0..1] |
7111 Z6502570 | Heat/cold | — | X | [1P0..1] |
7111 ZE502580 | E-mobility | — | X | [1P0..1] |
7111 ZA802590 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5602600 | Storage heating | — | X | — |
7111 Z5702610 | Heat pump (unspecified) | — | X | — |
7111 Z6102620 | Direct heating | — | X | — |
7111 ZV502630 | Heat pump (heat and cold) | — | X | — |
7111 ZV602640 | Heat pump (cold) | — | X | — |
7111 ZV702650 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE602660 | Wallbox | — | X | — |
7111 Z8702670 | E-mobility charging station | — | X | — |
7111 ZE702680 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF502690 | Solar | — | X | — |
7111 ZF602700 | Wind | — | X | — |
7111 ZG002710 | Gas | — | X | — |
7111 ZG102720 | Water | — | X | — |
7111 ZG502730 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF702740 | Hydrogen storage | — | X | — |
7111 ZF802750 | Pumped storage | — | X | — |
7111 ZF902760 | Battery storage | — | X | — |
7111 ZG602770 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG802780 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG902790 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6202800 | Data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802810 | Controllable resource | — | X | — |
115402820 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4902830 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF202840 | Service description of the control channel | — | X | — |
1131 Z1402850 | On/Off | — | X | — |
1131 Z1502860 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302870 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102880 | MSB | — | X | — |
113102890 | MP-ID | — | X | — |
7110 Z3902900 | Default metering point operator | — | X | — |
7110 Z4002910 | Competitive metering point operator | — | X | — |
7110 Z4102920 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6102930 | Product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802940 | Controllable resource | — | X | — |
115402950 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | [81] |
4347 502960 | Product identification | — | X | — |
714002970 | Configuration product code | — | X | — |
7143 Z1202980 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1102990 | Product | — | X | — |
7037 ZF603000 | No product assigned | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5203010 | Code of the switching time definition | — | X | — |
7059 Z5303020 | Code of the power curve definition | — | X | — |
703703030 | Code of the definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB303040 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803050 | NB | — | X | — |
7111 Z8903060 | LF | — | X | — |
113103070 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA803080 | NB | — | X | [1P0..1] |
7037 ZA703090 | LF | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z1803100 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903110 | Metering location | — | X | — |
115403120 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB303130 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9103140 | MSB | — | X | — |
113103150 | MP-ID | — | X | [621] |
7110 Z3903160 | Default metering point operator | — | X | — |
7110 Z4003170 | Competitive metering point operator | — | X | — |
7110 Z4103180 | Fallback metering point operator | — | X | — |
7110 Z1903190 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2003200 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF003210 | gMSB | — | X | — |
113103220 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | [184] |
7111 ZB403230 | MSBA | — | X | — |
113103240 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0403250 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0303260 | Extra-high voltage | — | X | — |
7111 E0403270 | High voltage | — | X | — |
7111 E0503280 | Medium voltage | — | X | — |
7111 E0603290 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0103300 | Scope of use | — | X | — |
7037 Z8203310 | ID of the metering location handled in the process | — | X | [2236] |
7037 Z8103320 | ID of the metering location in the location bundle | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3203330 | Operating state of the metering location | — | X | — |
7037 ZC103340 | Metering location blocked and may not be unblocked | — | X | — |
7037 ZC203350 | Metering location blocked and may be unblocked | — | X | — |
7037 ZC303360 | Metering location in regular operation | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1903370 | Required product of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903380 | Metering location | — | X | — |
115403390 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [429] |
1153 Z1803400 | Market location | — | X | — |
115403410 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 503420 | Product identification | — | X | — |
714003430 | Metering product code | — | X | [427] |
7143 Z1103440 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3503450 | Description required value | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZC903460 | Second measurement required for comparative measurement | — | X | — |
7110 Z0603470 | present | — | X | — |
7110 Z0703480 | not present | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803490 | NB | — | X | — |
7110 Z0603500 | present | — | X | — |
7110 Z0703510 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3903520 | Code of the metering time period definition | — | X | — |
7059 Z4103530 | No metering time period required for metering product | — | X | [417] |
703703540 | Code of the metering time period definition | — | X | [438] |
| SG8.SEQ | — | — | Must | — |
1229 Z0303550 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903560 | Metering location | — | X | — |
115403570 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1403580 | Smart meter gateway | — | X | — |
115403590 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1303600 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ03610 | analog household meter (three-phase current) | — | X | — |
7111 WSZ03620 | analog alternating current meter | — | X | — |
7111 LAZ03630 | Load curve meter | — | X | — |
7111 MAZ03640 | Maximum demand meter | — | X | — |
7111 MME03650 | modern metering device according to MsbG | — | X | — |
7111 EHZ03660 | electronic household meter | — | X | — |
7111 IVA03670 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0103680 | EDL40 | — | X | [136] |
7110 Z0203690 | EDL21 | — | X | [136] |
7110 Z0303700 | other EHZ | — | X | [136] |
7110 Z0403710 | Standard | — | X | [346] |
7110 Z0503720 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3003730 | Device number | — | X | — |
711003740 | Device number | — | X | — |
| SG10.CAV | — | — | Must | [139] |
7111 ETZ03750 | Single tariff | — | X | — |
7111 ZTZ03760 | Two-tariff | — | X | — |
7111 NTZ03770 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ERZ03780 | Single-direction meter | — | X | — |
7111 ZRZ03790 | Bidirectional meter | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5803800 | Remote switching of the metering device | — | X | — |
7110 Z0603810 | present | — | X | — |
7110 Z0703820 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2803830 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 BKE03840 | Plug-in technology (mounting and contacting device) | — | X | — |
7111 DPA03850 | 3- Three-point suspension | — | X | — |
7111 HUT03860 | DIN rail | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1203870 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR03880 | remotely readable meters | — | X | — |
7111 MMR03890 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2003900 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [78] ∧ [665] |
1153 MG03910 | Device number of the meter | — | X | [441] |
1153 Z1403920 | Smart meter gateway | — | X | — |
115403930 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [78] |
1153 Z1903940 | Metering location | — | X | — |
115403950 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [78] ∧ [402] ∧ [420] ∧ [651] |
1153 Z1803960 | Market location | — | X | — |
115403970 | ID of a market location | — | X | [950] |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK03980 | Application reference number | — | X | — |
115403990 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 504000 | Product identification | — | X | — |
714004010 | OBIS code of the metering device | — | X | [323] |
7143 SRW04020 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE404030 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD904040 | Annually | — | X | — |
7111 ZE804050 | Semi-annual | — | X | — |
7111 ZE904060 | Quarterly | — | X | — |
7111 ZB704070 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1104080 | Product | — | X | — |
7037 Z3304090 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711004100 | Digits before the decimal point | — | X | — |
711004110 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6304120 | Local identifier for control purposes | — | X | — |
703604130 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0404140 | Instrument transformer data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04150 | Device number of the meter | — | X | — |
115404160 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2504170 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3004180 | Device number | — | X | — |
711004190 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW04200 | Current transformer set | — | X | — |
7111 MPW04210 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW04220 | Block current transformer | — | X | — |
7111 MUW04230 | Voltage transformer set | — | X | — |
711004240 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 Z0504250 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04260 | Device number of the meter | — | X | — |
115404270 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2604280 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004290 | Device number | — | X | — |
711004300 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM04310 | GSM/GPRS/UMTS- comm. dev. | — | X | — |
7111 ETH04320 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC04330 | PLC comm. device | — | X | — |
7111 PST04340 | Landline comm. dev. TAE | — | X | — |
7111 DSL04350 | DSL comm. dev. | — | X | — |
7111 LTE04360 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0604370 | Data of the technical control device | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04380 | Device number of the meter | — | X | — |
115404390 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2704400 | Technical control device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004410 | Device number | — | X | — |
711004420 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 RSU04430 | Ripple control receiver | — | X | — |
7111 TSU04440 | Tariff time switch | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1304450 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7504460 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004470 | Device number | — | X | — |
711004480 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z1404490 | Control box | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1404500 | Smart meter gateway | — | X | — |
115404510 | Identification / number of the smart meter gateway | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804520 | Market location | — | X | — |
115404530 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 Z7604540 | Control box | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004550 | Device number | — | X | — |
711004560 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z2104570 | Profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804580 | Market location | — | X | — |
115404590 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0204600 | Standard load profile | — | X | — |
7059 Z0404610 | Standard feed-in profile | — | X | — |
7037 E0104620 | synthetic method | — | X | — |
7037 Z1004630 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711104640 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0804650 | Profile set data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804660 | Market location | — | X | — |
115404670 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0304680 | day-parameter-dependent load profile | — | X | — |
7059 Z0504690 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0104700 | synthetic method | — | X | — |
7037 Z1004710 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711104720 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9904730 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA004740 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703704750 | ID of climate zone / temperature measuring point | — | X | — |
113104760 | Service provider | — | X | [58] |
3055 8904770 | Assigned by the trader (here grid operator) | — | X | — |
3055 29304780 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z3804790 | Reference profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804800 | Market location | — | X | — |
115404810 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0504820 | day-parameter-dependent feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711104830 | Code of the reference profile | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0904840 | Customer of the LF | — | X | — |
303604850 | Name | — | X | — |
3045 Z0104860 | Structure of person names | — | X | — |
3045 Z0204870 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1804880 | Market location | — | X | — |
115404890 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0404900 | Correspondence address of the customer of the LF | — | X | — |
303604910 | Name | — | X | — |
3045 Z0104920 | Structure of person names | — | X | — |
3045 Z0204930 | Structure of the company name | — | X | — |
304204940 | Street and house number or PO box | — | X | — |
316404950 | City | — | X | — |
325104960 | Postal code | — | — | M [268] S [166] |
320704970 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1804980 | Market location | — | X | — |
115404990 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0705000 | Customer of the MSB | — | X | — |
303605010 | Name | — | X | — |
3045 Z0105020 | Structure of person names | — | X | — |
3045 Z0205030 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905040 | Metering location | — | X | — |
115405050 | ID of the metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0805060 | Correspondence address of the customer of the MSB | — | X | — |
303605070 | Name | — | X | — |
3045 Z0105080 | Structure of person names | — | X | — |
3045 Z0205090 | Structure of the company name | — | X | — |
304205100 | Street and house number or PO box | — | X | — |
316405110 | City | — | X | — |
325105120 | Postal code | — | — | M [268] S [166] |
320705130 | Country name, code | — | X | — |
| SG13.CTA | — | — | Must | — |
3139 IC05140 | Information contact | — | X | — |
| SG13.COM | — | — | Must | — |
314805150 | Number / address | — | X | — |
3155 TE05160 | Telephone | — | X | [1P0..1] |
3155 EM05170 | Electronic mail | — | X | [1P0..1] |
| SG12.NAD | — | — | Must | — |
3035 Z2505180 | Customer of the NB | — | X | — |
303605190 | Name | — | X | — |
3045 Z0105200 | Structure of person names | — | X | — |
3045 Z0205210 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805220 | Market location | — | X | — |
115405230 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z2605240 | Correspondence address of the customer of the NB | — | X | — |
303605250 | Name | — | X | — |
3045 Z0105260 | Structure of person names | — | X | — |
3045 Z0205270 | Structure of the company name | — | X | — |
304205280 | Street and house number or PO box | — | X | — |
316405290 | City | — | X | — |
325105300 | Postal code | — | — | M [268] S [166] |
320705310 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805320 | Market location | — | X | — |
115405330 | ID of the market location | — | X | [950] |
| SG13.CTA | — | — | Must | — |
3139 IC05340 | Information contact | — | X | — |
| SG13.COM | — | — | Must | — |
314805350 | Number / address | — | X | — |
3155 TE05360 | Telephone | — | X | [1P0..1] |
3155 EM05370 | Electronic mail | — | X | [1P0..1] |
| SG12.NAD | — | — | Must | — |
3035 Z0305380 | Metering location address | — | X | — |
312405390 | Additional information for identification | — | — | — |
304205400 | Street and house number or PO box | — | — | S [166] M [212] |
316405410 | City | — | X | — |
325105420 | Postal code | — | X | — |
320705430 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905440 | Metering location | — | X | — |
115405450 | ID of a metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0505460 | Name and address for the meter reading card | — | X | — |
303605470 | Name | — | X | — |
3045 Z0105480 | Structure of person names | — | X | — |
3045 Z0205490 | Structure of the company name | — | X | — |
304205500 | Street and house number or PO box | — | X | — |
316405510 | City | — | X | — |
325105520 | Postal code | — | — | M [268] S [166] |
320705530 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905540 | Metering location | — | X | — |
115405550 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007405560 | Number of segments in a message | — | X | — |
006205570 | Message reference number | — | X | — |
Conditions of this table
The free text of the 106 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [78] | If SG4 STS+7++E02 (transaction reason: move-in to creation) is not present |
| [81] | If in the same SG8 SEQ+Z61/ZB3/ZB4 (product data of the controllable resource) the SG10 CCI+11 (details on the product of the controllable resource) is not present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) CAV+ZE5 (e-mobility) is present |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [139] | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [159] | If in the same SG8 SEQ+Z57 (OBIS data of the grid location) the SG10 CCI+11 (OBIS data of the grid location) is not present |
| [166] | If present |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle struct ure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle struc ture) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) with an identical code in DE1229 |
| [184] | If in the same SG8 SEQ+Z18 (data of the metering location) a CCI+Z01++Z82 (scope of use: ID of the metering location handled in the process) is present |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [221] | If no SG8 SEQ+Z15 (data of the tranche) references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z01 (data of the market location) |
| [234] | If SG10 CCI+++Z83 (metering classification of the market location) CAV+Z53 (kME/mME) is present |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+Z65 (heat/cooling) |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle ) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [353] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [354] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [381] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [382] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [383] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/ÜNB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [417] | If no metering time period is required for the required value |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [425] | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| [426] | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| [427] | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| [429] | If in the same SG8 SEQ+Z19/ZF4 (required metering product of the metering location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.3.1 standard metering product of the metering location with the option of assigning a |
| [438] | If code Z39 (code of the metering time period) is present in DE7059 in the same CCI |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption ) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation ) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [618] | Note: Previous date of the MSBA. If the MSBN wishes to use a different date, it communicates the new date by means of a master data change |
| [621] | Note: The MSB must be specified that is assigned to the location from the point in time named in DTM+76 (date of the planned start of supply). |
| [637] | Note: In the case of a commitment request |
| [638] | Note: In the event of a request to take over the individual metering location by the gMSB |
| [651] | Note: The market locations for which the OBIS named here is required must be specified |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [701] | Note: The Malo ID of the tranche to which the technical resource is assigned must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2236] | Code once per SG4 IDE+24 (transaction) |
| [2312] | If the object code "9992000001256" (grid location) is not present in DE1154 of the same RFF+Z33, the RFF+Z33 must be specified exactly once in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle ) |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer ) is present, the segment must be specified exactly once |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [19P1..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [22P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [26P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [22P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [23P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [27P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [23P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [38P1..1] | [419] If no other package in this SG10 in the same SG8 SEQ leads to the possibility of specifying at least one other code in this data element |
| [19P0..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [26P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [25P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present |
| [1P1..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9904446000007:500+{{date}}:{{time}}+M3FXU3PV'
UNH+UNHM44RYD60+UTILMD:D:11A:UN:S2.2'
BGM+E01+BGMM42HSI1V'
DTM+137:202610021100?+00:303'
NAD+MS+9900321000005::293'
NAD+MR+9904446000007::293'
IDE+24+123456'
DTM+76:202606302200?+00:303'
STS+7++E03'
LOC+Z18+E1688117482'
LOC+Z16+50074561188'
LOC+Z20+D417MLM8164'
LOC+Z19+C816417ST77'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55168'
RFF+Z50:50074561188'
DTM+752:0101:106'
SEQ+Z78'
RFF+Z31:9992000000026'
SEQ+Z58'
RFF+Z32:E1688117482'
RFF+Z33:9992000001256'
SEQ+Z58'
RFF+Z18:50074561188'
RFF+Z33:9992000001016'
SEQ+Z58'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001032'
SEQ+Z58'
RFF+Z37:D417MLM8164'
RFF+Z33:9992000001024'
SEQ+Z51'
RFF+Z32:E1688117482'
CCI+Z49++ZF3'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+Z57'
RFF+Z32:E1688117482'
PIA+5+1-1?:5.29.0:SRW+:V12:Z16+:V12:Z16'
SEQ+Z60'
RFF+Z32:E1688117482'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
CCI+++ZB3'
CAV+Z88:9900321000005'
CCI+++ZA8'
SEQ+Z01'
RFF+Z18:50074561188'
QTY+31:2000:KWH'
CCI+Z30++Z07'
CCI+++ZB3'
CAV+Z89:9903790000002'
CAV+Z90:4045399000077'
CAV+Z91:9904446000007::Z39:Z20'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+6++ZA8'
CCI+++ZA6'
CAV+E02'
CCI+ZA2++ZE9'
SEQ+Z27'
RFF+Z18:50074561188'
PIA+5+9991000000044:Z11'
CCI+Z41'
CCI+++ZA8'
CAV+ZE1'
CCI+++ZA7'
CAV+Z47'
SEQ+Z52'
RFF+Z37:D417MLM8164'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+Z62'
RFF+Z38:C816417ST77'
CCI+Z49'
CAV+ZF2:Z14'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+Z61'
RFF+Z38:C816417ST77'
PIA+5+9991000000713:Z12'
CCI+Z52++ABC'
CCI+++ZB3'
CAV+Z88:9900321000005'
CCI+++ZA8'
SEQ+Z18'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39:Z20'
CAV+ZF0:9904446000007'
CAV+ZB4:9904446000007'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
CCI+Z32++ZC3'
SEQ+Z19'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z18:50074561188'
PIA+5+9991000000151:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
CCI+Z41'
SEQ+Z03'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::EL001IK01013852469'
CAV+ETZ'
CAV+ERZ'
CAV+Z58:::Z07'
CCI+++Z28'
CAV+BKE'
CCI+++E12'
CAV+MMR'
SEQ+Z20'
RFF+MG:EL001IK01013852469'
RFF+Z19:DE0032106765712000000000000000037'
PIA+5+1-1?:1.8.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::7:3'
SEQ+Z21'
RFF+Z18:50074561188'
CCI+Z02++E01'
CAV+H0'
NAD+Z09+++Mustermann:Max::::Z01'
RFF+Z18:50074561188'
NAD+Z07+++Mustermann:Max::::Z01'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z08+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
CTA+IC'
COM+max@mustermann.de:EM'
NAD+Z03++Mustermann:Max++Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z05+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
UNT+144+UNHM44RYD60'
UNZ+1+M3FXU3PV'[1 item
{6 fields
"data": {3 fields
"stammdaten": {11 fields
"MARKTLOKATION": [1 item
{10 fields
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{3 fields
"verwendungszwecke": [2 items
{2 fields
{2 fields
"zweck": [1 item
"zaehlzeiten": {1 field
"NETZLOKATION": [1 item
{11 fields
"auftraggebenderMarktpartner": {4 fields
"marktrollen": [1 item
{7 fields
"zaehlwerke": [1 item
{3 fields
"MESSLOKATION": [1 item
{12 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{4 fields
"zaehlzeiten": {1 field
"ablesekartenempfaenger": {7 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [3 items
{8 fields
{6 fields
{6 fields
"TECHNISCHE_RESSOURCE": [1 item
{12 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"STEUERBARE_RESSOURCE": [1 item
{10 fields
"auftraggebenderMarktpartner": {4 fields
"marktrollen": [1 item
{7 fields
"zugeordneteDefinition": {1 field
"LOKATIONSBUENDEL": [1 item
{5 fields
"zuordnungObjectcode": [4 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"MESSSTELLENBETRIEBSVERTRAG": [1 item
{9 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"vertragskonditionen": {1 field
"geplanteTurnusablesung": {1 field
"korrespondenzpartner": {7 fields
"partneradresse": {5 fields
"ansprechpartner": {3 fields
"ENERGIELIEFERVERTRAG": [1 item
{7 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"ZAEHLER": [1 item
{14 fields
"zaehlwerke": [1 item
{4 fields
"geraete": [1 item
{1 field
"BILANZIERUNG": [1 item
{9 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {12 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | End of metering point operation | WiM electricity part 1 | Electricity | Step 3 |
| NB | NB | End of metering point operation | WiM electricity part 1 | Electricity | Step 7 |
| MSB | GMSB | End of metering point operation | WiM electricity part 1 | Electricity | Step 3 |
| MSB | GMSB | End of metering point operation | WiM electricity part 1 | Electricity | Step 7 |
| MSB | MSBA | End of metering point operation | WiM electricity part 1 | Electricity | Step 3 |
| MSB | MSBA | End of metering point operation | WiM electricity part 1 | Electricity | Step 7 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Commitment request / demand |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | End of metering point operation | NB → MSB (corresponds to gMSB on the metering location object) | Commitment request |
| WiM electricity part 1 | End of metering point operation | NB → MSB (corresponds to gMSB on the metering location object) | Request to take over the individual metering location by the gMSB |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Which messages respond to this
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | 55169 | Confirmation of commitment request | UTILMD | from the step sequence |
| Response | 55170 | Rejection commitment request | UTILMD | from the step sequence |
This column is the inverse of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 778 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.