Check identifier 55239 — Response to registration
Check identifier 55239 · EDIFACT message type UTILMD · format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55239 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | [56] |
2005 9200220 | Contract start date | — | X | — |
238000230 | Date or time or time span, value | — | X | [UB1] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [56] |
2005 15800250 | Start of balancing | — | X | — |
238000260 | Date or time or time span, value | — | X | [UB1] ∧ [317] |
2379 30300270 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700280 | Transaction reason | — | X | — |
9013 E0300290 | Change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100300 | Status of the response | — | X | — |
901300310 | Code of the check step | — | X | — |
1131 E_051000320 | EBD no. E_0510 | — | X | — |
1131 E_051300330 | EBD no. E_0513 | — | X | — |
| SG4.FTX | — | — | Must | [48] |
4451 ACB00340 | Additional information (for general notes) | — | X | — |
444000350 | Text for general information | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1600360 | Market location | — | X | — |
322500370 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1500380 | MaBiS metering point | — | X | — |
322500390 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300400 | Check identifier | — | X | — |
1154 5523900410 | E-Mob / response to registration in model 2 | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00420 | Transaction reference number | — | X | — |
115400430 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0100440 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800450 | Market location | — | X | — |
115400460 | ID of the market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 ZB300470 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100480 | MSB | — | X | — |
113100490 | MP-ID | — | X | — |
7110 Z3900500 | Default metering point operator | — | X | — |
7110 Z4000510 | Competitive metering point operator | — | X | — |
7110 Z4100520 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0200530 | OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800540 | Market location | — | X | — |
115400550 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 500560 | Product identification | — | X | — |
714000570 | OBIS code of the market location | — | X | — |
7143 SRW00580 | OBIS code | — | X | — |
714300590 | Purpose of use NB | — | X | [381] |
1131 Z1600600 | EDI@Energy code list of purposes of use | — | X | — |
714300610 | Purpose of use LF | — | X | [382] |
1131 Z1600620 | EDI@Energy code list of purposes of use | — | X | — |
714300630 | Purpose of use ÜNB | — | X | [383] |
1131 Z1600640 | EDI@Energy code list of purposes of use | — | X | — |
| UNT | — | — | Must | — |
007400650 | Number of segments in a message | — | X | — |
006200660 | Message reference number | — | X | — |
Conditions of this table
The free text of the 12 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [48] | If the STS+E01++A99 (status of the response: other) is present in this SG4 |
| [56] | If a response code from the consent cluster is present in DE9013 (status of the response) in the STS+E01 |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| [317] | The same value as in DE2380 of DTM+92 (contract start date) must be entered |
| [381] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [382] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [383] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/ÜNB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [931] | Format: ZZZ = +00 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and NB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Registration of a market location in model 2 by the NB (LPB) | AWH Model 2 charg.-session-level bal. energy assign. option | Electricity | Step 4 |
| NB | LPB | Registration of a market location in model 2 by the NB (LPB) | AWH Model 2 charg.-session-level bal. energy assign. option | Electricity | Step 4 |
| NB | NB | Registration of a market location in model 2 by the NB (LPB) | AWH Model 2 charg.-session-level bal. energy assign. option | Electricity | Step 4 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to registration |
| AHB | UTILMD AHB electricity |
| Decision tree | E_0513 · E_0510 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| AWH Model 2 charg.-session-level bal. energy assign. option | Registration of a market location in model 2 by the NB (LPB) | NB (VNB) → NB (LPB) | Response to registration |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 89 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.