Check identifier 55060 — Response to GDA
Check identifier 55060 · EDIFACT message type UTILMD · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 55060 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] | — | object[] | May | — |
| detailsPrognosegrundlage 00010 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| prognosegrundlage 00020 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00030 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00040 | Value | number (float) | X | — |
| temperaturarbeit | — | object | May | — |
| einheit 00050 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00060 | Value | number (float) | Must | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00070 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00080 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00090 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00100 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00110 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00120 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00130 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00140 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00150 | lokationsbuendelNummer | integer | X | — |
| objectcode 00160 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| energierichtung 00170 | Indicates whether energy is fed in or drawn (fed out). | Enum Energierichtung | X | — |
AUSSP | — | — | X | — |
EINSP | — | — | X | — |
| marktlokationsId * 00180 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00190 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00200 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00210 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00220 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00230 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00240 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00250 | weiterverpflichtet | boolean | X | — |
| technischeEinrichtungen [ ] | — | object[] | May | — |
| technischeEinrichtungenVorhanden 00260 | true => ZH7, false => ZH8 | boolean | Must | — |
| verbrauchsart 00270 | Consumption type | Enum Verbrauchsart | Must | — |
KL | — | — | Must | — |
W | — | — | Must | — |
EMOB | — | — | Must | — |
SB | — | — | Must | — |
SW | — | — | Must | — |
WK | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00280 | messprodukt | string | X | — |
| obisKennzahl 00290 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszweckLF 00300 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 00310 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| verwendungszweckUENB 00320 | Codes according to the code list of the purposes of use Purpose of use ÜNB | string | X | — |
| wertegranularitaet 00330 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00340 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00350 | Metering time period definition | string | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00360 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00370 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| verwendungsumfang 00380 | Scope of use | Enum Verwendungsumfang | X | — |
MESSLOKATION_PROZESSUAL_BEHANDELT | — | — | X | — |
MESSLOKATION_LOKATIONSBUENDEL | — | — | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00390 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00400 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00410 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00420 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00430 | House number and supplement | string | X | — |
| landescode 00440 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00450 | City | string | X | — |
| ortsteil 00460 | District | string | X | — |
| postfach 00470 | PO box | string | X | — |
| postleitzahl 00480 | Postal code | string | X | — |
| strasse 00490 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00500 | Address supplement 1 | string | X | — |
| zusatz2 00510 | Address supplement 2 | string | X | — |
| zusatz3 00520 | Address supplement 3 | string | X | — |
| zusatz4 00530 | Address supplement 4 | string | X | — |
| zusatz5 00540 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00550 | messprodukt | string | X | — |
| notwendigkeitZweiteMessung 00560 | Necessity of second measurement | Enum NotwendigkeitZweiteMessung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| werteuebermittlungVerwendungszweck 00570 | Purpose of use for value transmission | Enum WerteuebermittlungVerwendungszweck | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| zaehlzeiten | — | object | May | — |
| zaehlzeitDefinition 00580 | Metering time period definition | string | Must | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 00590 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00600 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 00610 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| steuerkanal 00620 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00630 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00640 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00650 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| keinProdukt 00660 | CCI+11++ZF6: no product assigned | boolean | X | — |
| obisKennzahl 00670 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszweckLF 00680 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 00690 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| keinKonfigurationsprodukt 00700 | keinKonfigurationsprodukt | boolean | X | — |
| konfigurationsprodukt 00710 | konfigurationsprodukt | string | X | — |
| ressourcenId 00720 | ressourcenId | string | X | — |
| steuerkanal 00730 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00740 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00750 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00760 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 00770 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 00780 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 00790 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 00800 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| enwg 00810 | enwg | boolean | Must | — |
| erzeugungsart 00820 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| referenzNetzlokation 00830 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 00840 | referenzSteuerbareRessource | string | X | — |
| referenzTranche 00850 | referenzTranche | string | X | — |
| ressourcenId 00860 | ressourcenId | string | X | — |
| speicherart 00870 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 00880 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 00890 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | — |
| waermenutzung 00900 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| nennleistung | — | object | May | — |
| abgabe 00910 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 00920 | Recording of the rated power | number (float) | X | — |
| TRANCHE [ ] | — | object[] | May | — |
| bildungTranchengroesse 00930 | BildungTranchengroesse | Enum BildungTranchengroesse | X | — |
PROZENTUAL | — | — | X | — |
AUFTEILUNGSFAKTOR | — | — | X | — |
AUFTEILUNG_TECHNISCHE_RESSOURCEN | — | — | X | — |
BERECHNUNGSFORMEL | — | — | X | — |
| referenzMarktlokationsId 00940 | referenzMarktlokationsId | string | X | — |
| tranchenId 00950 | tranchenId | string | X | — |
| aufteilungsmenge | — | object | May | — |
| einheit 00960 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00970 | Value | number (float) | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00980 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 00990 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01000 | messprodukt | string | X | — |
| verwendungszweckLF 01010 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 01020 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| verwendungszweckUENB 01030 | Codes according to the code list of the purposes of use Purpose of use ÜNB | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| gateway 01040 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| messlokationsId 01050 | messlokationsId | string | X | — |
| messwerterfassung 01060 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlernummer 01070 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 01080 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 01090 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 01100 | The number printed on the device, which is assigned by the MSB. | string | Must | — |
| geraetetyp 01110 | List of possible billable device types | Enum Geraetetyp | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
RLM_ZAEHLER | — | — | Must | — |
IMS_ZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
MULTIPLEXANLAGE | — | — | Must | — |
PAUSCHALANLAGE | — | — | Must | — |
VERSTAERKERANLAGE | — | — | Must | — |
SUMMATIONSGERAET | — | — | Must | — |
IMPULSGEBER | — | — | Must | — |
EDL_21_ZAEHLERAUFSATZ | — | — | Must | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | Must | — |
MENGENUMWERTER | — | — | Must | — |
STROMWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
DATENLOGGER | — | — | Must | — |
KOMMUNIKATIONSANSCHLUSS | — | — | Must | — |
MODEM | — | — | Must | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
DREHKOLBENGASZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MODERNE_MESSEINRICHTUNG | — | — | Must | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | Must | — |
STEUEREINRICHTUNG | — | — | Must | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER_IMS_MME | — | — | Must | — |
TARIFSCHALTGERAET_IMS_MME | — | — | Must | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | Must | — |
TEMPERATUR_KOMPENSATION | — | — | Must | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | Must | — |
SONSTIGES_GERAET | — | — | Must | — |
SMARTMETERGATEWAY | — | — | Must | — |
STEUERBOX | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
PLC_COM | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
WANDLER | — | — | Must | — |
BEFESTIGUNGSEINRICHTUNG | — | — | Must | — |
| weitereGeraetenummern 01120 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 01130 | faktor | number (float) | Must | — |
| geraetemerkmal 01140 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| konfiguration 01150 | Configuration (iMSys) of the meter register | string | X | — |
| obisKennzahl 01160 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 01170 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 01180 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 01190 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 01200 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 01210 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 01220 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 01230 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 01240 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 01250 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 01260 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01270 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 01280 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01290 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55060 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E4400070 | Information notification | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMM ZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document/message issuer or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700220 | Transaction reason | — | X | — |
9013 ZY400230 | Response to GDA to MSB | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800240 | Grid location | — | X | — |
322500250 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600260 | Market location | — | X | — |
322500270 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2200280 | Dormant market location | — | X | — |
322500290 | ID of the dormant market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000300 | Technical resource | — | X | — |
322500310 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900320 | Controllable resource | — | X | — |
322500330 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z2100340 | Tranche | — | X | — |
322500350 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700360 | Metering location | — | X | — |
322500370 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300380 | Check identifier | — | X | — |
1154 5506000390 | WiM electricity / response to the MSB GDA | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 AAV00400 | Number of the request | — | X | — |
115400410 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZD500420 | Informative reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100430 | Location bundle structure | — | X | — |
1153 Z3900440 | No standardized location bundle structure available | — | X | — |
115400450 | ID of the location bundle structure | — | X | [333] |
115600460 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 ZD600470 | Informative assignment of location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200480 | Grid location | — | X | — |
1153 Z1800490 | Market location | — | X | — |
1153 Z1900500 | Metering location | — | X | — |
1153 Z3700510 | Technical resource | — | X | — |
115400520 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2312] |
1153 Z3300530 | Object code of the location in the location bundle structure | — | X | — |
115400540 | Object code | — | X | — |
115600550 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400560 | upstream metering location | — | X | — |
1153 Z3500570 | upstream grid location | — | X | — |
115400580 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600590 | assigned market location | — | X | — |
115400600 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 ZD700610 | Informative data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200620 | Grid location | — | X | — |
115400630 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900640 | Control channel | — | X | — |
7037 ZF200650 | No control channel available | — | X | — |
7037 ZF300660 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300670 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100680 | MSB | — | X | — |
113100690 | MP-ID | — | X | — |
7110 Z3900700 | Default metering point operator | — | X | — |
7110 Z4000710 | Competitive metering point operator | — | X | — |
7110 Z4100720 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZD900730 | Informative OBIS data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200740 | Grid location | — | X | — |
115400750 | ID of the grid location | — | X | [960] |
| SG8.PIA | — | — | Must | [159] |
4347 500760 | Product identification | — | X | — |
714000770 | OBIS code of the grid location | — | X | — |
7143 SRW00780 | OBIS code | — | X | — |
714300790 | Purpose of use NB | — | X | [353] |
1131 Z1600800 | EDI@Energy code list of purposes of us e | — | X | — |
714300810 | Purpose of use LF | — | X | [354] |
1131 Z1600820 | EDI@Energy code list of purposes of us e | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1100830 | Product | — | X | — |
7037 ZF600840 | No product assigned | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE000850 | Informative product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200860 | Grid location | — | X | — |
115400870 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 500880 | Product identification | — | X | — |
714000890 | Configuration product code | — | X | [412] |
7143 Z1200900 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5300910 | Code of the power curve definition | — | X | — |
703700920 | Code of the power curve definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z9800930 | Informative data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800940 | Market location | — | X | — |
115400950 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 26500960 | Estimated annual quantity total/ annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0800970 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606000980 | Quantity | — | X | [902] |
6411 Z1600990 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH01000 | Kilowatt hour | — | X | [104] |
| SG9.QTY | — | — | Must | — |
6063 3101010 | Estimated annual quantity total | — | X | — |
606001020 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH01030 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3001040 | Delivery direction | — | X | — |
7037 Z0601050 | Generation | — | X | — |
7037 Z0701060 | Consumption | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301070 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | [224] |
7111 Z8901080 | LF | — | X | — |
113101090 | MP-ID | — | X | [611] |
| SG10.CAV | — | — | Must | — |
7111 Z9001100 | ÜNB | — | X | — |
113101110 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101120 | MSB | — | X | — |
113101130 | MP-ID | — | X | — |
7110 Z3901140 | Default metering point operator | — | X | — |
7110 Z4001150 | Competitive metering point operator | — | X | — |
7110 Z4101160 | Fallback metering point operator | — | X | — |
7110 Z1901170 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001180 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301190 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301200 | Extra-high voltage | — | X | — |
7111 E0401210 | High voltage | — | X | — |
7111 E0501220 | Medium voltage | — | X | — |
7111 E0601230 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301240 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201250 | iMS | — | X | — |
7111 Z5301260 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001270 | Forecast based on values | — | X | — |
7037 ZA601280 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [210] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0201290 | SLP/SEP | — | X | [1P0..1] |
7111 E1401300 | TLP/TEP | — | X | [1P0..1] |
7111 Z3601310 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3401320 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3301330 | EEG market location without DV obligation | — | X | — |
7111 Z3401340 | KWKG- Market location without direct marketing obligation | — | X | — |
7111 Z3501350 | other market location | — | X | — |
7111 Z3701360 | EEG market location with DV obligation | — | X | — |
7111 Z4601370 | KWKG- Market location with direct marketing obligation | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE201380 | Informative required metering product of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801390 | Market location | — | X | — |
115401400 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501410 | Product identification | — | X | — |
714001420 | Metering product code | — | X | [425] |
7143 Z1101430 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901440 | Code of the metering time period definition | — | X | — |
7059 Z4101450 | No metering time period required for metering product | — | X | [417] |
703701460 | Code of the metering time period definition | — | X | [438] |
| SG8.SEQ | — | — | Must | — |
1229 ZE301470 | Informative OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801480 | Market location | — | X | — |
115401490 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501500 | Product identification | — | X | — |
714001510 | OBIS code of the market location | — | X | [314] |
7143 SRW01520 | OBIS code | — | X | — |
714301530 | Purpose of use NB | — | X | [381] |
1131 Z1601540 | EDI@Energy code list of purposes of us e | — | X | — |
714301550 | Purpose of use LF | — | X | [382] |
1131 Z1601560 | EDI@Energy code list of purposes of us e | — | X | — |
714301570 | Purpose of use ÜNB | — | X | [383] |
1131 Z1601580 | EDI@Energy code list of purposes of us e | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401590 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901600 | Annually | — | X | — |
7111 ZE801610 | Semi-annual | — | X | — |
7111 ZE901620 | Quarterly | — | X | — |
7111 ZB701630 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901640 | Code of the metering time period definition | — | X | — |
703701650 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3801660 | Code of the metering time period register | — | X | — |
703701670 | Code of the metering time period register | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE701680 | Informative data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2001690 | Tranche | — | X | — |
115401700 | ID of the tranche | — | X | [950] |
| SG8.RFF | — | — | Must | — |
1153 Z1601710 | assigned market location | — | X | — |
115401720 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 1101730 | Distribution quantity | — | X | — |
606001740 | Quantity specification in % | — | X | [914] ∧ [930] ∧ [955] |
6411 P101750 | Percent | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301760 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8901770 | LF | — | X | — |
113101780 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3701790 | Basis for determining the tranche size | — | X | — |
7037 ZD101800 | Percentage-based | — | X | — |
7037 ZD201810 | Distribution factor based on reference carrier/ installed capacity | — | X | — |
7037 ZH101820 | Distribution across technical resources | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE801830 | Informative required product of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2001840 | Tranche | — | X | — |
115401850 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501860 | Product identification | — | X | — |
714001870 | Metering product code | — | X | [426] |
7143 Z1101880 | Product | — | X | — |
| SG10.CAV | — | — | Must | [446] |
| SG8.SEQ | — | — | Must | — |
1229 ZF001890 | Informative data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3701900 | Technical resource | — | X | — |
115401910 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3801920 | Controllable resource | — | X | — |
115401930 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3201940 | Grid location | — | X | — |
115401950 | ID of the grid location | — | X | [960] |
| SG8.RFF | — | — | Should | [166] ∧ [447] ∧ [701] |
1153 Z2001960 | Tranche | — | X | — |
115401970 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z4301980 | Rated power (input) | — | X | — |
606001990 | Quantity | — | X | — |
6411 KWT02000 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4402010 | Rated power (output) | — | X | — |
606002020 | Quantity | — | X | — |
6411 KWT02030 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4202040 | Storage capacity | — | X | — |
606002050 | Quantity | — | X | — |
6411 KWH02060 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1702070 | Type of electricity consumption | — | X | — |
7059 Z5002080 | Type of electricity generation | — | X | — |
7059 Z5602090 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6402100 | Power/light | — | X | [1P0..1] |
7111 Z6502110 | Heat/cold | — | X | [1P0..1] |
7111 ZE502120 | E-mobility | — | X | [1P0..1] |
7111 ZA802130 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5602140 | Storage heating | — | X | — |
7111 Z5702150 | Heat pump (unspecified) | — | X | — |
7111 Z6102160 | Direct heating | — | X | — |
7111 ZV502170 | Heat pump (heat and cold) | — | X | — |
7111 ZV602180 | Heat pump (cold) | — | X | — |
7111 ZV702190 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE602200 | Wallbox | — | X | — |
7111 Z8702210 | E- mobility charging station | — | X | — |
7111 ZE702220 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF502230 | Solar | — | X | — |
7111 ZF602240 | Wind | — | X | — |
7111 ZG002250 | Gas | — | X | — |
7111 ZG102260 | Water | — | X | — |
7111 ZG502270 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF702280 | Hydrogen storage | — | X | — |
7111 ZF802290 | Pumped storage | — | X | — |
7111 ZF902300 | Battery storage | — | X | — |
7111 ZG602310 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG802320 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG902330 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF102340 | Informative data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802350 | Controllable resource | — | X | — |
115402360 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4902370 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF202380 | Service description of the control channel | — | X | — |
1131 Z1402390 | On/Off | — | X | — |
1131 Z1502400 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302410 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102420 | MSB | — | X | — |
113102430 | MP-ID | — | X | — |
7110 Z3902440 | Default metering point operator | — | X | — |
7110 Z4002450 | Competitive metering point operator | — | X | — |
7110 Z4102460 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF202470 | Informative product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802480 | Controllable resource | — | X | — |
115402490 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | [81] |
4347 502500 | Product identification | — | X | — |
714002510 | Configuration product code | — | X | — |
7143 Z1202520 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1102530 | Product | — | X | — |
7037 ZF602540 | No product assigned | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5202550 | Code of the switching time definition | — | X | — |
7059 Z5302560 | Code of the power curve definition | — | X | — |
703702570 | Code of the definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF302580 | Informative data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902590 | Metering location | — | X | — |
115402600 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB302610 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102620 | MSB | — | X | — |
113102630 | MP-ID | — | X | — |
7110 Z3902640 | Default metering point operator | — | X | — |
7110 Z4002650 | Competitive metering point operator | — | X | — |
7110 Z4102660 | Fallback metering point operator | — | X | — |
7110 Z1902670 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2002680 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF002690 | gMSB | — | X | — |
113102700 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0402710 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0302720 | Extra-high voltage | — | X | — |
7111 E0402730 | High voltage | — | X | — |
7111 E0502740 | Medium voltage | — | X | — |
7111 E0602750 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0102760 | Scope of use | — | X | — |
7037 Z8202770 | ID of the metering location handled in the process | — | X | [2236] |
7037 Z8102780 | ID of the metering location in the location bundle | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF402790 | Informative required product of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902800 | Metering location | — | X | — |
115402810 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 502820 | Product identification | — | X | — |
714002830 | Metering product code | — | X | [427] |
7143 Z1102840 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3502850 | Description required value | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZC902860 | Second measurement required for comparative measuremen t | — | X | — |
7110 Z0602870 | present | — | X | — |
7110 Z0702880 | not present | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8802890 | NB | — | X | — |
7110 Z0602900 | present | — | X | — |
7110 Z0702910 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3902920 | Code of the metering time period definition | — | X | — |
7059 Z4102930 | No metering time period required for metering product | — | X | [417] |
703702940 | Code of the metering time period definition | — | X | [438] |
| SG8.SEQ | — | — | Must | — |
1229 ZF502950 | Informative metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902960 | Metering location | — | X | — |
115402970 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1402980 | Smart meter gateway | — | X | — |
115402990 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1303000 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ03010 | analog household meter (three-phase current) | — | X | — |
7111 WSZ03020 | analog alternating current meter | — | X | — |
7111 LAZ03030 | Load curve meter | — | X | — |
7111 MAZ03040 | Maximum demand meter | — | X | — |
7111 MME03050 | modern metering device according to MsbG | — | X | — |
7111 EHZ03060 | electronic household meter | — | X | — |
7111 IVA03070 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0103080 | EDL40 | — | X | [136] |
7110 Z0203090 | EDL21 | — | X | [136] |
7110 Z0303100 | other EHZ | — | X | [136] |
7110 Z0403110 | Standard | — | X | [346] |
7110 Z0503120 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3003130 | Device number | — | X | — |
711003140 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1203150 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR03160 | remotely readable meters | — | X | — |
7111 MMR03170 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF603180 | Informative OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [665] |
1153 MG03190 | Device number of the meter | — | X | [441] |
1153 Z1403200 | Smart meter gateway | — | X | — |
115403210 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK03220 | Application reference number | — | X | — |
115403230 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 503240 | Product identification | — | X | — |
714003250 | OBIS code of the metering device | — | X | [323] |
7143 SRW03260 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE403270 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD903280 | Annually | — | X | — |
7111 ZE803290 | Semi-annual | — | X | — |
7111 ZE903300 | Quarterly | — | X | — |
7111 ZB703310 | Monthly | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF703320 | Informative instrument transformer data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG03330 | Device number of the meter | — | X | — |
115403340 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2503350 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3003360 | Device number | — | X | — |
711003370 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW03380 | Current transformer set | — | X | — |
7111 MPW03390 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW03400 | Block current transforme r | — | X | — |
7111 MUW03410 | Voltage transformer set | — | X | — |
711003420 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 ZF803430 | Informative communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG03440 | Device number of the meter | — | X | — |
115403450 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2603460 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3003470 | Device number | — | X | — |
711003480 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM03490 | GSM/GPRS/UMTS- comm. dev. | — | X | — |
7111 ETH03500 | Ethernet comm. dev. LAN/ WLAN | — | X | — |
7111 PLC03510 | PLC comm. device | — | X | — |
7111 PST03520 | Landline comm. dev. TAE | — | X | — |
7111 DSL03530 | DSL comm. dev. | — | X | — |
7111 LTE03540 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF903550 | Informative data of the technical control device | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG03560 | Device number of the meter | — | X | — |
115403570 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2703580 | Technical control device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3003590 | Device number | — | X | — |
711003600 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 RSU03610 | Ripple control receiver | — | X | — |
7111 TSU03620 | Tariff time switch | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG003630 | Informative smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7503640 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3003650 | Device number | — | X | — |
711003660 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 Z6403670 | Informative metering location address | — | X | — |
312403680 | Additional information for identification | — | — | — |
304203690 | Street and house number or PO box | — | — | S [166] M [212] |
316403700 | City | — | X | — |
325103710 | Postal code | — | X | — |
320703720 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1903730 | Metering location | — | X | — |
115403740 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007403750 | Number of segments in a message | — | X | — |
006203760 | Message reference number | — | X | — |
Conditions of this table
The free text of the 75 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [81] | If in the same SG8 SEQ+Z61/ZB3/ZB4 (product data of the controllable resource) the SG10 CCI+11 (details on the product of the controllable resource) is not present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) CAV+ZE5 (e-mobility) is present |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [159] | If in the same SG8 SEQ+Z57 (OBIS data of the grid location) the SG10 CCI+11 (OBIS data of the grid location) is not present |
| [166] | If present |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle struct ure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle struc ture) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) with an identical code in DE1229 |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [224] | If no SG8 SEQ+ZE7 (informative data of the tranche) references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z98 (informative data of the market location) |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+Z65 (heat/cooling) |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle ) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [353] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [354] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [381] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [382] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [383] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/ÜNB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [417] | If no metering time period is required for the required value |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [425] | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| [426] | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| [427] | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| [438] | If code Z39 (code of the metering time period) is present in DE7059 in the same CCI |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption ) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation ) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [701] | Note: The Malo ID of the tranche to which the technical resource is assigned must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2236] | Code once per SG4 IDE+24 (transaction) |
| [2312] | If the object code "9992000001256" (grid location) is not present in DE1154 of the same RFF+Z33, the RFF+Z33 must be specified exactly once in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle ) |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer ) is present, the segment must be specified exactly once |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9900579000005:500+9906687000002:500+{{date}}:{{time}}+M52KI4TB'
UNH+UNHM4IJSO81+UTILMD:D:11A:UN:S2.2'
BGM+E44+BGMM4JRNG60'
DTM+137:202610021100?+00:303'
NAD+MS+9900579000005::293'
NAD+MR+9906687000002::293'
IDE+24+KBG27094210000000000929931413171000'
STS+7++ZY4'
LOC+Z18+E1688110018'
LOC+Z16+50363198116'
LOC+Z20+D417MLM8120'
LOC+Z20+D417MLM8121'
LOC+Z17+DE0032106765712000000000000001217'
LOC+Z17+DE0032106765712000000000000001218'
RFF+Z13:55060'
RFF+AAV:1234567890'
SEQ+ZD5'
RFF+Z31:9992000000109'
SEQ+ZD6'
RFF+Z32:E1688110018'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z37:D417MLM8120'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z37:D417MLM8121'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z18:50363198116'
RFF+Z33:9992000001016'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001217'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001218'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD7'
RFF+Z32:E1688110018'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39'
SEQ+ZD9'
RFF+Z32:E1688110018'
PIA+5+1-0?:5.29.0:SRW+:V14:Z16+:V14:Z16'
SEQ+ZE0'
RFF+Z32:E1688110018'
PIA+5+9991000000721:Z12'
CCI+Z53++XZY'
SEQ+Z98'
RFF+Z18:50363198116'
CCI+Z30++Z06'
CCI+++ZB3'
CAV+Z89:9900496000004'
CAV+Z90:9900496000005'
CAV+Z91:9900496000003::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZC0'
CCI+++Z34'
CAV+Z33'
SEQ+ZE2'
RFF+Z18:50363198116'
PIA+5+9991000000078:Z11'
SEQ+ZE3'
RFF+Z18:50363198116'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF0'
RFF+Z37:D417MLM8120'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF0'
RFF+Z37:D417MLM8121'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z81'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001217'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001218'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA1'
CCI+++E12'
CAV+MMR'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA2'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:BLABLA1'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF6'
RFF+MG:BLABLA2'
PIA+5+1-1?:1.29.0:SRW'
NAD+Z64++Max:Mustermann++Str::1+Weimar++12345+DE'
RFF+Z19:DE0032106765712000000000000001217'
UNT+136+UNHM4IJSO81'
UNZ+1+M52KI4TB'[1 item
{6 fields
"data": {3 fields
"stammdaten": {7 fields
"MARKTLOKATION": [1 item
{12 fields
"energieherkunft": [1 item
{1 field
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"NETZLOKATION": [1 item
{10 fields
"marktrollen": [1 item
{7 fields
"zaehlwerke": [1 item
{3 fields
"MESSLOKATION": [2 items
{10 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
{9 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [2 items
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [6 items
{3 fields
"objectcode": [1 item
{1 field
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{3 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
"ZAEHLER": [2 items
{9 fields
"zaehlwerke": [1 item
{1 field
{9 fields
"zaehlwerke": [1 item
{1 field
"BILANZIERUNG": [1 item
{5 fields
"transaktionsdaten": {12 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Business data request | GPKE part 4 | Electricity | Step 2 |
| NB | NB | Business data request | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | Business data request | GPKE part 4 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to GDA |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Business data request | NB → MSB | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Request: No reference recorded in the source. Neither the Prüfi table (reaktion_auf) nor the step sequence of the processes names the message that this response answers.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+AAV | dokumentennummer |
RFF+AAV quotes the preceding message via its BGM; the target is the dokumentennummer of the request. Which request is meant is not determined on this page (see above) — the target field is thus named, but not proven.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 527 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.