Check identifier 55223 — DZÜ list
Check identifier 55223 · EDIFACT message type UTILMD · format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55223 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
006800070 | General assignment reference | — | — | S [1] |
007000080 | Transmission sequence number | — | — | M [252] |
0073 C00090 | Start | — | — | M [2] |
0073 F00100 | End | — | — | S [3] |
| BGM | — | — | Must | — |
1001 Z3700110 | DZÜ list | — | X | — |
100400120 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700130 | Document/message date/time | — | X | — |
238000140 | Date or time or time span, value | — | X | [931] [494] |
2379 30300150 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 15700160 | Validity, start date | — | X | — |
238000170 | Date or time or time span, value | — | X | — |
2379 61000180 | CCYYMM | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00190 | Document-/ message sender or sender | — | X | — |
303900200 | MP-ID | — | X | — |
3055 900210 | GS1 | — | X | — |
3055 29300220 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00230 | Message recipient | — | X | — |
303900240 | MP-ID | — | X | [280] |
3055 900250 | GS1 | — | X | — |
3055 29300260 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | [564] |
7495 Z0100270 | List | — | X | — |
740200280 | List number | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500290 | MaBiS metering point | — | X | — |
322500300 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300310 | Check identifier | — | X | — |
1154 5522300320 | MaBiS / DZÜ list | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2200330 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AUU00340 | Reference to a time series | — | X | — |
115400350 | Version of the time series | — | X | — |
| SG4.IDE | — | — | Must | [565] |
7495 2400360 | Transaction | — | X | — |
740200370 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700380 | Transaction reason | — | X | — |
9013 ZP300390 | Master data | — | X | — |
9013 ZP400400 | Values | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1600410 | Market location | — | X | — |
322500420 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2100430 | Tranche | — | X | — |
322500440 | ID of the tranche | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 Z4700450 | Data status of the ÜNB | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3100460 | Estimated annual quantity total | — | X | — |
606000470 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00480 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z3600490 | Energy quantity: DZÜ share | — | X | — |
606000500 | Quantity specification | — | X | — |
6411 KWH00510 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15800520 | Start of balancing | — | X | — |
238000530 | Date or time or time span, value | — | X | [UB1] |
2379 30300540 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15900550 | End of balancing | — | X | — |
238000560 | Date or time or time span, value | — | X | [UB1] |
2379 30300570 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4500580 | Energy quantity to be balanced | — | X | — |
606000590 | Quantity specification | — | X | — |
6411 KWH00600 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15800610 | Start of balancing | — | X | — |
238000620 | Date or time or time span, value | — | X | [UB1] |
2379 30300630 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15900640 | End of balancing | — | X | — |
238000650 | Date or time or time span, value | — | X | [UB1] |
2379 30300660 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900670 | Balancing group | — | X | — |
703700680 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2000690 | Balancing area | — | X | — |
703700700 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500710 | Structure | — | X | — |
7037 Z2100720 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100730 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0200740 | Standard load profile | — | X | — |
7059 Z0400750 | Standard feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711100760 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 600770 | Responsible party | — | X | — |
7037 ZA800780 | NB | — | X | — |
7037 ZA900790 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZG300800 | Location in regular operation | — | X | — |
7111 ZG400810 | Location outside regular operation (decommissioning) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z4800820 | Billed data of the balancing group aggregated time series of ÜNB | — | X | — |
| SG8.RFF | — | — | Must | [660] |
1153 AVE00830 | Reporting point | — | X | — |
115400840 | ID of the aggregated time series | — | X | [951] |
| SG8.RFF | — | — | Must | — |
1153 AUU00850 | Reference to a time series | — | X | — |
115400860 | Version of the time series | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3100870 | Estimated annual quantity total | — | X | — |
606000880 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00890 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z0700900 | Actually balanced energy quantity | — | X | — |
606000910 | Quantity specification | — | X | — |
6411 KWH00920 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15800930 | Start of balancing | — | X | — |
238000940 | Date or time or time span, value | — | X | [UB1] ∧ [454] |
2379 30300950 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15900960 | End of balancing | — | X | — |
238000970 | Date or time or time span, value | — | X | [UB1] ∧ [455] |
2379 30300980 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900990 | Balancing group | — | X | — |
703701000 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2001010 | Balancing area | — | X | — |
703701020 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1501030 | Structure | — | X | — |
7037 Z2101040 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711101050 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0201060 | Standard load profile | — | X | — |
7059 Z0401070 | Standard feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711101080 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z4901090 | Billed data of the balancing area aggregate time series of ÜNB | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AVE01100 | Reporting point | — | X | — |
115401110 | ID of the aggregated time series | — | X | [951] |
| SG8.RFF | — | — | Must | — |
1153 AUU01120 | Reference to a time series | — | X | — |
115401130 | Version of the time series | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3101140 | Estimated annual quantity total | — | X | — |
606001150 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH01160 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z0701170 | Actually balanced energy quantity | — | X | — |
606001180 | Quantity specification | — | X | — |
6411 KWH01190 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15801200 | Start of balancing | — | X | — |
238001210 | Date or time or time span, value | — | X | [UB1] ∧ [454] |
2379 30301220 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15901230 | End of balancing | — | X | — |
238001240 | Date or time or time span, value | — | X | [UB1] ∧ [455] |
2379 30301250 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2001260 | Balancing area | — | X | — |
703701270 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1501280 | Structure | — | X | — |
7037 Z2101290 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711101300 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0201310 | Standard load profile | — | X | — |
7059 Z0401320 | Standard feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711101330 | Code of the standardized profile | — | X | — |
| UNT | — | — | Must | — |
007401340 | Number of segments in a message | — | X | — |
006201350 | Message reference number | — | X | — |
Conditions of this table
The free text of the 17 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [1] | If a split is present |
| [2] | If UNH DE0070 (transmission sequence number) with 1 is present |
| [3] | In the case of splitting, in the message with the highest transmission sequence number |
| [252] | If DE0068 is present |
| [280] | Only MP-ID from the electricity division |
| [454] | The balancing start date must be earlier than the balancing end date in the SG8 “Data status of the ÜNB”, SG 9 energy quantity DZÜ share |
| [455] | The balancing end date must be later than the balancing start date in the SG8 “Data status of the ÜNB” , SG 9 energy quantity DZÜ share |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [660] | Note: The ID of the BK aggregated time series, aggregation level BG, must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Exchange of the delta time series carry-over list from ÜNB to NB | MaBiS | Electricity | Step 1 |
| ÜNB | ÜNB | Exchange of the delta time series carry-over list from ÜNB to NB | MaBiS | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | DZÜ list |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Exchange of the delta time series carry-over list from ÜNB to NB | ÜNB → NB | Transmission of the DZÜ list |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 192 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.