Check identifier 55060 — Response to GDA
Check identifier 55060 · EDIFACT message type UTILMD · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 55060 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] | — | object[] | May | — |
| detailsPrognosegrundlage 00010 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| prognosegrundlage 00020 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00030 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00040 | Value | number (float) | X | — |
| temperaturarbeit | — | object | May | — |
| einheit 00050 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00060 | Value | number (float) | Must | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00070 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00080 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00090 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00100 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00110 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00120 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00130 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00140 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00150 | lokationsbuendelNummer | integer | X | — |
| objectcode 00160 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| energierichtung 00170 | Indicates whether energy is fed in or drawn (fed out). | Enum Energierichtung | X | — |
AUSSP | — | — | X | — |
EINSP | — | — | X | — |
| konfigurationsprodukt 00180 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00190 | Code of the assigned power curve definition for the object | string | X | — |
| marktlokationsId * 00200 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00210 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00220 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00230 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00240 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00250 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00260 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00270 | weiterverpflichtet | boolean | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00280 | messprodukt | string | X | — |
| obisKennzahl 00290 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 00300 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00310 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00320 | Metering time period definition | string | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00330 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00340 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| verwendungsumfang 00350 | Scope of use | Enum Verwendungsumfang | X | — |
MESSLOKATION_PROZESSUAL_BEHANDELT | — | — | X | — |
MESSLOKATION_LOKATIONSBUENDEL | — | — | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00360 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00370 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00380 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00390 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00400 | House number and supplement | string | X | — |
| landescode 00410 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00420 | City | string | X | — |
| ortsteil 00430 | District | string | X | — |
| postfach 00440 | PO box | string | X | — |
| postleitzahl 00450 | Postal code | string | X | — |
| strasse 00460 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00470 | Address supplement 1 | string | X | — |
| zusatz2 00480 | Address supplement 2 | string | X | — |
| zusatz3 00490 | Address supplement 3 | string | X | — |
| zusatz4 00500 | Address supplement 4 | string | X | — |
| zusatz5 00510 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00520 | messprodukt | string | X | — |
| notwendigkeitZweiteMessung 00530 | Necessity of second measurement | Enum NotwendigkeitZweiteMessung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| werteuebermittlungVerwendungszweck 00540 | Purpose of use for value transmission | Enum WerteuebermittlungVerwendungszweck | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| zaehlzeiten | — | object | May | — |
| zaehlzeitDefinition 00550 | Metering time period definition | string | Must | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 00560 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00570 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 00580 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| steuerkanal 00590 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00600 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00610 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00620 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| obisKennzahl 00630 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| konfigurationsprodukt 00640 | konfigurationsprodukt | string | X | — |
| ressourcenId 00650 | ressourcenId | string | X | — |
| steuerkanal 00660 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00670 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00680 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00690 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 00700 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 00710 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 00720 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 00730 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| enwg 00740 | enwg | boolean | Must | — |
| erzeugungsart 00750 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| referenzNetzlokation 00760 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 00770 | referenzSteuerbareRessource | string | X | — |
| ressourcenId 00780 | ressourcenId | string | X | — |
| speicherart 00790 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 00800 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 00810 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | — |
| waermenutzung 00820 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| weitereEinrichtung 00830 | weitereEinrichtung | boolean | Must | — |
| nennleistung | — | object | May | — |
| abgabe 00840 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 00850 | Recording of the rated power | number (float) | X | — |
| TRANCHE [ ] | — | object[] | May | — |
| bildungTranchengroesse 00860 | BildungTranchengroesse | Enum BildungTranchengroesse | X | — |
PROZENTUAL | — | — | X | — |
AUFTEILUNGSFAKTOR | — | — | X | — |
AUFTEILUNG_TECHNISCHE_RESSOURCEN | — | — | X | — |
BERECHNUNGSFORMEL | — | — | X | — |
| referenzMarktlokationsId 00870 | referenzMarktlokationsId | string | X | — |
| tranchenId 00880 | tranchenId | string | X | — |
| aufteilungsmenge | — | object | May | — |
| einheit 00890 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00900 | Value | number (float) | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00910 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 00920 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00930 | messprodukt | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| gateway 00940 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| messlokationsId 00950 | messlokationsId | string | X | — |
| messwerterfassung 00960 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlernummer 00970 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00980 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00990 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 01000 | The number printed on the device, which is assigned by the MSB. | string | Must | — |
| geraetetyp 01010 | List of possible billable device types | Enum Geraetetyp | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
RLM_ZAEHLER | — | — | Must | — |
IMS_ZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
MULTIPLEXANLAGE | — | — | Must | — |
PAUSCHALANLAGE | — | — | Must | — |
VERSTAERKERANLAGE | — | — | Must | — |
SUMMATIONSGERAET | — | — | Must | — |
IMPULSGEBER | — | — | Must | — |
EDL_21_ZAEHLERAUFSATZ | — | — | Must | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | Must | — |
MENGENUMWERTER | — | — | Must | — |
STROMWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
DATENLOGGER | — | — | Must | — |
KOMMUNIKATIONSANSCHLUSS | — | — | Must | — |
MODEM | — | — | Must | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
DREHKOLBENGASZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MODERNE_MESSEINRICHTUNG | — | — | Must | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | Must | — |
STEUEREINRICHTUNG | — | — | Must | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER_IMS_MME | — | — | Must | — |
TARIFSCHALTGERAET_IMS_MME | — | — | Must | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | Must | — |
TEMPERATUR_KOMPENSATION | — | — | Must | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | Must | — |
SONSTIGES_GERAET | — | — | Must | — |
SMARTMETERGATEWAY | — | — | Must | — |
STEUERBOX | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
PLC_COM | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
WANDLER | — | — | Must | — |
BEFESTIGUNGSEINRICHTUNG | — | — | Must | — |
| weitereGeraetenummern 01020 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 01030 | faktor | number (float) | Must | — |
| geraetemerkmal 01040 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| konfiguration 01050 | Configuration (iMSys) of the meter register | string | X | — |
| obisKennzahl 01060 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 01070 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 01080 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 01090 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 01100 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 01110 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 01120 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 01130 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 01140 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 01150 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 01160 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01170 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 01180 | Email address | string | Must | — |
| nachname 01190 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 01200 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 01210 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 01220 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01230 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55060 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E4400070 | Information notification | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 29300270 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700300 | Transaction reason | — | X | — |
9013 ZY400310 | Response to GDA to MSB | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800320 | Grid location | — | X | — |
322500330 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600340 | Market location | — | X | — |
322500350 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2200360 | Dormant market location | — | X | — |
322500370 | ID of the dormant market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000380 | Technical resource | — | X | — |
322500390 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900400 | Controllable resource | — | X | — |
322500410 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z2100420 | Tranche | — | X | — |
322500430 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700440 | Metering location | — | X | — |
322500450 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300460 | Check identifier | — | X | — |
1154 5506000470 | WiM electricity / response to the MSB GDA | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 AAV00480 | Number of the request | — | X | — |
115400490 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZD500500 | Informative reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100510 | Location bundle structure | — | X | — |
1153 Z3900520 | No standardized location bundle structure available | — | X | — |
115400530 | ID of the location bundle structure | — | X | [333] |
115600540 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 ZD600550 | Informative assignment of location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200560 | Grid location | — | X | — |
1153 Z1800570 | Market location | — | X | — |
1153 Z1900580 | Metering location | — | X | — |
1153 Z3700590 | Technical resource | — | X | — |
115400600 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2312] |
1153 Z3300610 | Object code of the location in the location bundle structure | — | X | — |
115400620 | Object code | — | X | — |
115600630 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400640 | upstream metering location | — | X | — |
1153 Z3500650 | upstream grid location | — | X | — |
115400660 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600670 | assigned market location | — | X | — |
115400680 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 ZD700690 | Informative data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200700 | Grid location | — | X | — |
115400710 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900720 | Control channel | — | X | — |
7037 ZF200730 | No control channel available | — | X | — |
7037 ZF300740 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300750 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100760 | MSB | — | X | — |
113100770 | MP-ID | — | X | — |
7110 Z3900780 | Default metering point operator | — | X | — |
7110 Z4000790 | Competitive metering point operator | — | X | — |
7110 Z4100800 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZD900810 | Informative OBIS data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200820 | Grid location | — | X | — |
115400830 | ID of the grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 500840 | Product identification | — | X | — |
714000850 | OBIS code of the grid location | — | X | — |
7143 SRW00860 | OBIS code | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE000870 | Informative product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200880 | Grid location | — | X | — |
115400890 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 500900 | Product identification | — | X | — |
714000910 | Configuration product code | — | X | [412] |
7143 Z1200920 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5300930 | Code of the power curve definition | — | X | — |
703700940 | Code of the power curve definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z9800950 | Informative data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800960 | Market location | — | X | — |
115400970 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 26500980 | Estimated annual quantity total/annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0800990 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606001000 | Quantity | — | X | [902] |
6411 Z1601010 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH01020 | Kilowatt hour | — | X | [104] |
| SG9.QTY | — | — | Must | — |
6063 3101030 | Estimated annual quantity total | — | X | — |
606001040 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH01050 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3001060 | Delivery direction | — | X | — |
7037 Z0601070 | Generation | — | X | — |
7037 Z0701080 | Consumption | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301090 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | [224] |
7111 Z8901100 | LF | — | X | — |
113101110 | MP-ID | — | X | [611] |
| SG10.CAV | — | — | Must | — |
7111 Z9001120 | ÜNB | — | X | — |
113101130 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101140 | MSB | — | X | — |
113101150 | MP-ID | — | X | — |
7110 Z3901160 | Default metering point operator | — | X | — |
7110 Z4001170 | Competitive metering point operator | — | X | — |
7110 Z4101180 | Fallback metering point operator | — | X | — |
7110 Z1901190 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001200 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301210 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301220 | Extra-high voltage | — | X | — |
7111 E0401230 | High voltage | — | X | — |
7111 E0501240 | Medium voltage | — | X | — |
7111 E0601250 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301260 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201270 | iMS | — | X | — |
7111 Z5301280 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001290 | Forecast based on values | — | X | — |
7037 ZA601300 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [210] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0201310 | SLP/SEP | — | X | [1P0..1] |
7111 E1401320 | TLP/TEP | — | X | [1P0..1] |
7111 Z3601330 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3401340 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3301350 | EEG market location without DV obligation | — | X | — |
7111 Z3401360 | KWKG market location without DV obligation | — | X | — |
7111 Z3501370 | other market location | — | X | — |
7111 Z3701380 | EEG market location with DV obligation | — | X | — |
7111 Z4601390 | KWKG market location with DV obligation | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE201400 | Informative required metering product of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801410 | Market location | — | X | — |
115401420 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501430 | Product identification | — | X | — |
714001440 | Metering product code | — | X | [425] |
7143 Z1101450 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901460 | Code of the metering time period definition | — | X | — |
7059 Z4101470 | No metering time period required for metering product | — | X | [417] |
703701480 | Code of the metering time period definition | — | X | [438] |
| SG8.SEQ | — | — | Must | — |
1229 ZE301490 | Informative OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801500 | Market location | — | X | — |
115401510 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501520 | Product identification | — | X | — |
714001530 | OBIS code of the market location | — | X | [314] |
7143 SRW01540 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401550 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901560 | Annually | — | X | — |
7111 ZE801570 | Semi-annual | — | X | — |
7111 ZE901580 | Quarterly | — | X | — |
7111 ZB701590 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901600 | Code of the metering time period definition | — | X | — |
703701610 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3801620 | Code of the metering time period register | — | X | — |
703701630 | Code of the metering time period register | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE401640 | Informative product data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801650 | Market location | — | X | — |
115401660 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501670 | Product identification | — | X | — |
714001680 | Product/service number | — | X | — |
7143 Z1201690 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5301700 | Code of the power curve definition | — | X | — |
703701710 | Code of the definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE701720 | Informative data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2001730 | Tranche | — | X | — |
115401740 | ID of the tranche | — | X | [950] |
| SG8.RFF | — | — | Must | — |
1153 Z1601750 | assigned market location | — | X | — |
115401760 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 1101770 | Distribution quantity | — | X | — |
606001780 | Quantity specification in % | — | X | [914] ∧ [930] ∧ [955] |
6411 P101790 | Percent | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301800 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8901810 | LF | — | X | — |
113101820 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3701830 | Basis for determining the tranche size | — | X | — |
7037 ZD101840 | Percentage-based | — | X | — |
7037 ZD201850 | Distribution factor based on reference carrier/installed capacity | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE801860 | Informative required product of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2001870 | Tranche | — | X | — |
115401880 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501890 | Product identification | — | X | — |
714001900 | Metering product code | — | X | [426] |
7143 Z1101910 | Product | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF001920 | Informative data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3701930 | Technical resource | — | X | — |
115401940 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3801950 | Controllable resource | — | X | — |
115401960 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3201970 | Grid location | — | X | — |
115401980 | ID of the grid location | — | X | [960] |
| SG9.QTY | — | — | Must | — |
6063 Z4301990 | Rated power (input) | — | X | — |
606002000 | Quantity | — | X | — |
6411 KWT02010 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4402020 | Rated power (output) | — | X | — |
606002030 | Quantity | — | X | — |
6411 KWT02040 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4202050 | Storage capacity | — | X | — |
606002060 | Quantity | — | X | — |
6411 KWH02070 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1702080 | Type of electricity consumption | — | X | — |
7059 Z5002090 | Type of electricity generation | — | X | — |
7059 Z5602100 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6402110 | Power/light | — | X | [1P0..1] |
7111 Z6502120 | Heat/cold | — | X | [1P0..1] |
7111 ZE502130 | E-mobility | — | X | [1P0..1] |
7111 ZA802140 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5602150 | Storage heating | — | X | — |
7111 Z5702160 | Heat pump (unspecified) | — | X | — |
7111 Z6102170 | Direct heating | — | X | — |
7111 ZV502180 | Heat pump (heat and cold) | — | X | — |
7111 ZV602190 | Heat pump (cold) | — | X | — |
7111 ZV702200 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE602210 | Wallbox | — | X | — |
7111 Z8702220 | E-mobility charging station | — | X | — |
7111 ZE702230 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF502240 | Solar | — | X | — |
7111 ZF602250 | Wind | — | X | — |
7111 ZG002260 | Gas | — | X | — |
7111 ZG102270 | Water | — | X | — |
7111 ZG502280 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF702290 | Hydrogen storage | — | X | — |
7111 ZF802300 | Pumped storage | — | X | — |
7111 ZF902310 | Battery storage | — | X | — |
7111 ZG602320 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG802330 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG902340 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z6302350 | Information on further technical equipment | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZH702360 | Further technical equipment present | — | X | — |
7111 ZH802370 | No further technical device available | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF102380 | Informative data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802390 | Controllable resource | — | X | — |
115402400 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4902410 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF202420 | Service description of the control channel | — | X | — |
1131 Z1402430 | On/Off | — | X | — |
1131 Z1502440 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302450 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102460 | MSB | — | X | — |
113102470 | MP-ID | — | X | — |
7110 Z3902480 | Default metering point operator | — | X | — |
7110 Z4002490 | Competitive metering point operator | — | X | — |
7110 Z4102500 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF202510 | Informative product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802520 | Controllable resource | — | X | — |
115402530 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | — |
4347 502540 | Product identification | — | X | — |
714002550 | Configuration product code | — | X | — |
7143 Z1202560 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5202570 | Code of the switching time definition | — | X | — |
7059 Z5302580 | Code of the power curve definition | — | X | — |
703702590 | Code of the definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF302600 | Informative data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902610 | Metering location | — | X | — |
115402620 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB302630 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102640 | MSB | — | X | — |
113102650 | MP-ID | — | X | — |
7110 Z3902660 | Default metering point operator | — | X | — |
7110 Z4002670 | Competitive metering point operator | — | X | — |
7110 Z4102680 | Fallback metering point operator | — | X | — |
7110 Z1902690 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2002700 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF002710 | gMSB | — | X | — |
113102720 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0402730 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0302740 | Extra-high voltage | — | X | — |
7111 E0402750 | High voltage | — | X | — |
7111 E0502760 | Medium voltage | — | X | — |
7111 E0602770 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0102780 | Scope of use | — | X | — |
7037 Z8202790 | ID of the metering location handled in the process | — | X | [2236] |
7037 Z8102800 | ID of the metering location in the location bundle | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF402810 | Informative required product of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902820 | Metering location | — | X | — |
115402830 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 502840 | Product identification | — | X | — |
714002850 | Metering product code | — | X | [427] |
7143 Z1102860 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3502870 | Description required value | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZC902880 | Second measurement required for comparative measurement | — | X | — |
7110 Z0602890 | present | — | X | — |
7110 Z0702900 | not present | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8802910 | NB | — | X | — |
7110 Z0602920 | present | — | X | — |
7110 Z0702930 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3902940 | Code of the metering time period definition | — | X | — |
7059 Z4102950 | No metering time period required for metering product | — | X | [417] |
703702960 | Code of the metering time period definition | — | X | [438] |
| SG8.SEQ | — | — | Must | — |
1229 ZF502970 | Informative metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902980 | Metering location | — | X | — |
115402990 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1403000 | Smart meter gateway | — | X | — |
115403010 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1303020 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ03030 | analog household meter (three-phase current) | — | X | — |
7111 WSZ03040 | analog alternating current meter | — | X | — |
7111 LAZ03050 | Load curve meter | — | X | — |
7111 MAZ03060 | Maximum demand meter | — | X | — |
7111 MME03070 | modern metering device according to MsbG | — | X | — |
7111 EHZ03080 | electronic household meter | — | X | — |
7111 IVA03090 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0103100 | EDL40 | — | X | [136] |
7110 Z0203110 | EDL21 | — | X | [136] |
7110 Z0303120 | other EHZ | — | X | [136] |
7110 Z0403130 | Standard | — | X | [346] |
7110 Z0503140 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3003150 | Device number | — | X | — |
711003160 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1203170 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR03180 | remotely readable meters | — | X | — |
7111 MMR03190 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF603200 | Informative OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [665] |
1153 MG03210 | Device number of the meter | — | X | [441] |
1153 Z1403220 | Smart meter gateway | — | X | — |
115403230 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK03240 | Application reference number | — | X | — |
115403250 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 503260 | Product identification | — | X | — |
714003270 | OBIS code of the metering device | — | X | [323] |
7143 SRW03280 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE403290 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD903300 | Annually | — | X | — |
7111 ZE803310 | Semi-annual | — | X | — |
7111 ZE903320 | Quarterly | — | X | — |
7111 ZB703330 | Monthly | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF703340 | Informative instrument transformer data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG03350 | Device number of the meter | — | X | — |
115403360 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2503370 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3003380 | Device number | — | X | — |
711003390 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW03400 | Current transformer set | — | X | — |
7111 MPW03410 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW03420 | Block current transformer | — | X | — |
7111 MUW03430 | Voltage transformer set | — | X | — |
711003440 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 ZF803450 | Informative communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG03460 | Device number of the meter | — | X | — |
115403470 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2603480 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3003490 | Device number | — | X | — |
711003500 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM03510 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH03520 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC03530 | PLC comm. device | — | X | — |
7111 PST03540 | Landline comm. dev. TAE | — | X | — |
7111 DSL03550 | DSL comm. dev. | — | X | — |
7111 LTE03560 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF903570 | Informative data of the technical control device | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG03580 | Device number of the meter | — | X | — |
115403590 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2703600 | Technical control device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3003610 | Device number | — | X | — |
711003620 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 RSU03630 | Ripple control receiver | — | X | — |
7111 TSU03640 | Tariff time switch | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG003650 | Informative smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7503660 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3003670 | Device number | — | X | — |
711003680 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 Z6403690 | Informative metering location address | — | X | — |
312403700 | Additional information for identification | — | — | — |
304203710 | Street and house number or PO box | — | — | S [166] M [212] |
316403720 | City | — | X | — |
325103730 | Postal code | — | X | — |
320703740 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1903750 | Metering location | — | X | — |
115403760 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007403770 | Number of segments in a message | — | X | — |
006203780 | Message reference number | — | X | — |
Conditions of this table
The free text of the 72 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption) CAV+ZE5 (e-mobility) is present |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [166] | If present |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) with an identical code in DE1229 |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [224] | If no SG8 SEQ+ZE7 (informative data of the tranche) references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z98 (informative data of the market location) |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption) is present in the CAV+Z65 (heat/cooling) |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [417] | If no metering time period is required for the required value |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [425] | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| [426] | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| [427] | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| [438] | If code Z39 (code of the metering time period) is present in DE7059 in the same CCI |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2236] | Code once per SG4 IDE+24 (transaction) |
| [2312] | If the object code "9992000001256" (grid location) is not present in DE1154 of the same RFF+Z33, the RFF+Z33 must be specified exactly once in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer) is present, the segment must be specified exactly once |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9900579000005:500+9906687000002:500+{{date}}:{{time}}+M52KI4TB'
UNH+UNHM4IJSO81+UTILMD:D:11A:UN:S2.1'
BGM+E44+BGMM4JRNG60'
DTM+137:202510050945?+00:303'
NAD+MS+9900579000005::293'
NAD+MR+9906687000002::293'
IDE+24+KBG27094210000000000929931413171000'
STS+7++ZY4'
LOC+Z18+E1688110018'
LOC+Z16+50363198116'
LOC+Z20+D417MLM8120'
LOC+Z20+D417MLM8121'
LOC+Z17+DE0032106765712000000000000001217'
LOC+Z17+DE0032106765712000000000000001218'
RFF+Z13:55060'
RFF+AAV:1234567890'
SEQ+ZD5'
RFF+Z31:9992000000109'
SEQ+ZD6'
RFF+Z32:E1688110018'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z37:D417MLM8120'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z37:D417MLM8121'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z18:50363198116'
RFF+Z33:9992000001016'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001217'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001218'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD7'
RFF+Z32:E1688110018'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39'
SEQ+ZD9'
RFF+Z32:E1688110018'
PIA+5+1-0?:5.29.0:SRW'
SEQ+ZE0'
RFF+Z32:E1688110018'
PIA+5+9991000000721:Z12'
CCI+Z53++XZY'
SEQ+Z98'
RFF+Z18:50363198116'
CCI+Z30++Z07'
CCI+++ZB3'
CAV+Z89:9900496000004'
CAV+Z90:9900496000005'
CAV+Z91:9900496000003::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZC0'
SEQ+ZE2'
RFF+Z18:50363198116'
PIA+5+9991000000078:Z11'
SEQ+ZE3'
RFF+Z18:50363198116'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF0'
RFF+Z37:D417MLM8120'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF0'
RFF+Z37:D417MLM8121'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z81'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001217'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001218'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA1'
CCI+++E12'
CAV+MMR'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA2'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:BLABLA1'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF6'
RFF+MG:BLABLA2'
PIA+5+1-1?:1.29.0:SRW'
NAD+Z64++Max:Mustermann++Str::1+Weimar++12345+DE'
RFF+Z19:DE0032106765712000000000000001217'
UNT+134+UNHM4IJSO81'
UNZ+1+M52KI4TB'[1 item
{6 fields
"data": {3 fields
"stammdaten": {7 fields
"MARKTLOKATION": [1 item
{11 fields
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"NETZLOKATION": [1 item
{10 fields
"marktrollen": [1 item
{7 fields
"zaehlwerke": [1 item
{1 field
"MESSLOKATION": [2 items
{10 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
{10 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [2 items
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [6 items
{3 fields
"objectcode": [1 item
{1 field
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{3 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
"ZAEHLER": [2 items
{9 fields
"zaehlwerke": [1 item
{1 field
{9 fields
"zaehlwerke": [1 item
{1 field
"BILANZIERUNG": [1 item
{5 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9900579000005:500+9906687000002:500+{{date}}:{{time}}+M52KI4TB'
UNH+UNHM4IJSO81+UTILMD:D:11A:UN:S2.1'
BGM+E44+BGMM4JRNG60'
DTM+137:202510050945?+00:303'
NAD+MS+9900579000005::293'
NAD+MR+9906687000002::293'
IDE+24+KBG27094210000000000929931413171000'
STS+7++ZY4'
LOC+Z18+E1688110018'
LOC+Z16+50363198116'
LOC+Z20+D417MLM8120'
LOC+Z20+D417MLM8121'
LOC+Z17+DE0032106765712000000000000001217'
LOC+Z17+DE0032106765712000000000000001218'
RFF+Z13:55060'
RFF+AAV:1234567890'
SEQ+ZD5'
RFF+Z31:9992000000109'
SEQ+ZD6'
RFF+Z32:E1688110018'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z37:D417MLM8120'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z37:D417MLM8121'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z18:50363198116'
RFF+Z33:9992000001016'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001217'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001218'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD7'
RFF+Z32:E1688110018'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39'
SEQ+ZD9'
RFF+Z32:E1688110018'
PIA+5+1-0?:5.29.0:SRW'
SEQ+ZE0'
RFF+Z32:E1688110018'
PIA+5+9991000000721:Z12'
CCI+Z53++XZY'
SEQ+Z98'
RFF+Z18:50363198116'
CCI+Z30++Z06'
CCI+++ZB3'
CAV+Z89:9900496000004'
CAV+Z90:9900496000005'
CAV+Z91:9900496000003::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZC0'
CCI+++Z34'
CAV+Z33'
SEQ+ZE2'
RFF+Z18:50363198116'
PIA+5+9991000000078:Z11'
SEQ+ZE3'
RFF+Z18:50363198116'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF0'
RFF+Z37:D417MLM8120'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF0'
RFF+Z37:D417MLM8121'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z81'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001217'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001218'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA1'
CCI+++E12'
CAV+MMR'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA2'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:BLABLA1'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF6'
RFF+MG:BLABLA2'
PIA+5+1-1?:1.29.0:SRW'
NAD+Z64++Max:Mustermann++Str::1+Weimar++12345+DE'
RFF+Z19:DE0032106765712000000000000001217'
UNT+136+UNHM4IJSO81'
UNZ+1+M52KI4TB'[1 item
{6 fields
"data": {3 fields
"stammdaten": {7 fields
"MARKTLOKATION": [1 item
{12 fields
"energieherkunft": [1 item
{1 field
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"NETZLOKATION": [1 item
{10 fields
"marktrollen": [1 item
{7 fields
"zaehlwerke": [1 item
{1 field
"MESSLOKATION": [2 items
{10 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
{10 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [2 items
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [6 items
{3 fields
"objectcode": [1 item
{1 field
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{3 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
"ZAEHLER": [2 items
{9 fields
"zaehlwerke": [1 item
{1 field
{9 fields
"zaehlwerke": [1 item
{1 field
"BILANZIERUNG": [1 item
{5 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9900579000005:500+9906687000002:500+{{date}}:{{time}}+M52KI4TB'
UNH+UNHM4IJSO81+UTILMD:D:11A:UN:S2.1'
BGM+E44+BGMM4JRNG60'
DTM+137:202604010945?+00:303'
NAD+MS+9900579000005::293'
NAD+MR+9906687000002::293'
IDE+24+KBG27094210000000000929931413171000'
STS+7++ZY4'
LOC+Z18+E1688110018'
LOC+Z16+50363198116'
LOC+Z20+D417MLM8120'
LOC+Z20+D417MLM8121'
LOC+Z17+DE0032106765712000000000000001217'
LOC+Z17+DE0032106765712000000000000001218'
RFF+Z13:55060'
RFF+AAV:1234567890'
SEQ+ZD5'
RFF+Z31:9992000000109'
SEQ+ZD6'
RFF+Z32:E1688110018'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z37:D417MLM8120'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z37:D417MLM8121'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z18:50363198116'
RFF+Z33:9992000001016'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001217'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001218'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD7'
RFF+Z32:E1688110018'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39'
SEQ+ZD9'
RFF+Z32:E1688110018'
PIA+5+1-0?:5.29.0:SRW'
SEQ+ZE0'
RFF+Z32:E1688110018'
PIA+5+9991000000721:Z12'
CCI+Z53++XZY'
SEQ+Z98'
RFF+Z18:50363198116'
CCI+Z30++Z06'
CCI+++ZB3'
CAV+Z89:9900496000004'
CAV+Z90:9900496000005'
CAV+Z91:9900496000003::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZC0'
CCI+++Z34'
CAV+Z33'
SEQ+ZE2'
RFF+Z18:50363198116'
PIA+5+9991000000078:Z11'
SEQ+ZE3'
RFF+Z18:50363198116'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF0'
RFF+Z37:D417MLM8120'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF0'
RFF+Z37:D417MLM8121'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z81'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001217'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001218'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA1'
CCI+++E12'
CAV+MMR'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA2'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:BLABLA1'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF6'
RFF+MG:BLABLA2'
PIA+5+1-1?:1.29.0:SRW'
NAD+Z64++Max:Mustermann++Str::1+Weimar++12345+DE'
RFF+Z19:DE0032106765712000000000000001217'
UNT+136+UNHM4IJSO81'
UNZ+1+M52KI4TB'[1 item
{6 fields
"data": {3 fields
"stammdaten": {7 fields
"MARKTLOKATION": [1 item
{12 fields
"energieherkunft": [1 item
{1 field
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"NETZLOKATION": [1 item
{10 fields
"marktrollen": [1 item
{7 fields
"zaehlwerke": [1 item
{1 field
"MESSLOKATION": [2 items
{10 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
{9 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [2 items
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [6 items
{3 fields
"objectcode": [1 item
{1 field
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{3 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
"ZAEHLER": [2 items
{9 fields
"zaehlwerke": [1 item
{1 field
{9 fields
"zaehlwerke": [1 item
{1 field
"BILANZIERUNG": [1 item
{5 fields
"transaktionsdaten": {12 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Example 4
UNA:+.? '
UNB+UNOC:3+9900579000005:500+9906687000002:500+{{date}}:{{time}}+M52KI4TB'
UNH+UNHM4IJSO81+UTILMD:D:11A:UN:S2.1'
BGM+E44+BGMM4JRNG60'
DTM+137:202604010945?+00:303'
NAD+MS+9900579000005::293'
NAD+MR+9906687000002::293'
IDE+24+KBG27094210000000000929931413171000'
STS+7++ZY4'
LOC+Z18+E1688110018'
LOC+Z16+50363198116'
LOC+Z20+D417MLM8120'
LOC+Z20+D417MLM8121'
LOC+Z17+DE0032106765712000000000000001217'
LOC+Z17+DE0032106765712000000000000001218'
RFF+Z13:55060'
RFF+AAV:1234567890'
SEQ+ZD5'
RFF+Z31:9992000000109:1'
SEQ+ZD5'
RFF+Z31:9992000000109:2'
SEQ+ZD6'
RFF+Z32:E1688110018'
RFF+Z33:9992000001256:1'
SEQ+ZD6'
RFF+Z37:D417MLM8120'
RFF+Z33:9992000001024:1'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z37:D417MLM8121'
RFF+Z33:9992000001024:1'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z18:50363198116'
RFF+Z33:9992000001016:1'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001217'
RFF+Z33:9992000001032:1'
RFF+Z35:E1688110018'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001218'
RFF+Z33:9992000001032:1'
RFF+Z35:E1688110018'
SEQ+ZD6'
RFF+Z32:E1688110018'
RFF+Z33:9992000001256:2'
SEQ+ZD6'
RFF+Z37:D417MLM8120'
RFF+Z33:9992000001024:2'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z37:D417MLM8121'
RFF+Z33:9992000001024:2'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z18:50363198116'
RFF+Z33:9992000001016:2'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001217'
RFF+Z33:9992000001032:2'
RFF+Z35:E1688110018'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001218'
RFF+Z33:9992000001032:2'
RFF+Z35:E1688110018'
SEQ+ZD7'
RFF+Z32:E1688110018'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39'
SEQ+ZD9'
RFF+Z32:E1688110018'
PIA+5+1-0?:5.29.0:SRW'
SEQ+ZE0'
RFF+Z32:E1688110018'
PIA+5+9991000000721:Z12'
CCI+Z53++XZY'
SEQ+Z98'
RFF+Z18:50363198116'
CCI+Z30++Z06'
CCI+++ZB3'
CAV+Z89:9900496000004'
CAV+Z90:9900496000005'
CAV+Z91:9900496000003::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZC0'
CCI+++Z34'
CAV+Z33'
SEQ+ZE2'
RFF+Z18:50363198116'
PIA+5+9991000000078:Z11'
SEQ+ZE3'
RFF+Z18:50363198116'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF0'
RFF+Z37:D417MLM8120'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF0'
RFF+Z37:D417MLM8121'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z81'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001217'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001218'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA1'
CCI+++E12'
CAV+MMR'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA2'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:BLABLA1'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF6'
RFF+MG:BLABLA2'
PIA+5+1-1?:1.29.0:SRW'
NAD+Z64++Max:Mustermann++Str::1+Weimar++12345+DE'
RFF+Z19:DE0032106765712000000000000001217'
UNT+160+UNHM4IJSO81'
UNZ+1+M52KI4TB'[1 item
{6 fields
"data": {3 fields
"stammdaten": {7 fields
"MARKTLOKATION": [1 item
{12 fields
"energieherkunft": [1 item
{1 field
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"NETZLOKATION": [1 item
{10 fields
"marktrollen": [1 item
{7 fields
"zaehlwerke": [1 item
{1 field
"MESSLOKATION": [2 items
{10 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
{9 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [2 items
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"LOKATIONSBUENDEL": [2 items
{7 fields
"zuordnungObjectcode": [6 items
{3 fields
"objectcode": [1 item
{2 fields
{4 fields
"objectcode": [1 item
{2 fields
"referenzMarktlokationTechnischeRessource": [1 item
{4 fields
"objectcode": [1 item
{2 fields
"referenzMarktlokationTechnischeRessource": [1 item
{3 fields
"objectcode": [1 item
{2 fields
{5 fields
"objectcode": [1 item
{2 fields
{5 fields
"objectcode": [1 item
{2 fields
{7 fields
"zuordnungObjectcode": [6 items
{3 fields
"objectcode": [1 item
{2 fields
{4 fields
"objectcode": [1 item
{2 fields
"referenzMarktlokationTechnischeRessource": [1 item
{4 fields
"objectcode": [1 item
{2 fields
"referenzMarktlokationTechnischeRessource": [1 item
{3 fields
"objectcode": [1 item
{2 fields
{5 fields
"objectcode": [1 item
{2 fields
{5 fields
"objectcode": [1 item
{2 fields
"ZAEHLER": [2 items
{9 fields
"zaehlwerke": [1 item
{1 field
{9 fields
"zaehlwerke": [1 item
{1 field
"BILANZIERUNG": [1 item
{5 fields
"transaktionsdaten": {12 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Example 5
UNA:+.? '
UNB+UNOC:3+9900579000005:500+9906687000002:500+{{date}}:{{time}}+M52KI4TB'
UNH+UNHM4IJSO81+UTILMD:D:11A:UN:S2.1'
BGM+E44+BGMM4JRNG60'
DTM+137:202604010945?+00:303'
NAD+MS+9900579000005::293'
NAD+MR+9906687000002::293'
IDE+24+KBG27094210000000000929931413171000'
STS+7++ZY4'
LOC+Z18+E1688110018'
LOC+Z16+50363198116'
LOC+Z20+D417MLM8120'
LOC+Z20+D417MLM8121'
LOC+Z17+DE0032106765712000000000000001217'
LOC+Z17+DE0032106765712000000000000001218'
RFF+Z13:55060'
RFF+AAV:1234567890'
SEQ+ZD5'
RFF+Z31:9992000000109'
SEQ+ZD6'
RFF+Z32:E1688110018'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z37:D417MLM8120'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z37:D417MLM8121'
RFF+Z33:9992000001024'
RFF+Z16:50363198116'
SEQ+ZD6'
RFF+Z18:50363198116'
RFF+Z33:9992000001016'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001217'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000001218'
RFF+Z33:9992000001032'
RFF+Z35:E1688110018'
SEQ+ZD7'
RFF+Z32:E1688110018'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39'
SEQ+ZD9'
RFF+Z32:E1688110018'
PIA+5+1-0?:5.29.0:SRW'
SEQ+ZE0'
RFF+Z32:E1688110018'
PIA+5+9991000000721:Z12'
CCI+Z53++XZY'
SEQ+Z98'
RFF+Z18:50363198116'
CCI+Z30++Z06'
CCI+++ZB3'
CAV+Z89:9900496000004'
CAV+Z90:9900496000005'
CAV+Z91:9900496000003::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZC0'
CCI+++Z34'
CAV+Z33'
SEQ+ZE2'
RFF+Z18:50363198116'
PIA+5+9991000000078:Z11'
SEQ+ZE3'
RFF+Z18:50363198116'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF0'
RFF+Z37:D417MLM8120'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF0'
RFF+Z37:D417MLM8121'
RFF+Z32:E1688110018'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG9'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++ZB3'
CAV+Z91:9900496000003::Z39:Z19'
CAV+ZF0:9900496000003'
CCI+++E04'
CAV+E06'
CCI+Z01++Z81'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001217'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF4'
RFF+Z19:DE0032106765712000000000000001218'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001217'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA1'
CCI+++E12'
CAV+MMR'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000001218'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::BLABLA2'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:BLABLA1'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZF6'
RFF+MG:BLABLA2'
PIA+5+1-1?:1.29.0:SRW'
NAD+Z64++Max:Mustermann++Str::1+Weimar++12345+DE'
RFF+Z19:DE0032106765712000000000000001217'
UNT+136+UNHM4IJSO81'
UNZ+1+M52KI4TB'[1 item
{6 fields
"data": {3 fields
"stammdaten": {7 fields
"MARKTLOKATION": [1 item
{12 fields
"energieherkunft": [1 item
{1 field
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"NETZLOKATION": [1 item
{10 fields
"marktrollen": [1 item
{7 fields
"zaehlwerke": [1 item
{1 field
"MESSLOKATION": [2 items
{10 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
{9 fields
"zaehlwerke": [1 item
{3 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [2 items
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{10 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [6 items
{3 fields
"objectcode": [1 item
{1 field
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{4 fields
"objectcode": [1 item
{1 field
"referenzMarktlokationTechnischeRessource": [1 item
{3 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
{5 fields
"objectcode": [1 item
{1 field
"ZAEHLER": [2 items
{9 fields
"zaehlwerke": [1 item
{1 field
{9 fields
"zaehlwerke": [1 item
{1 field
"BILANZIERUNG": [1 item
{5 fields
"transaktionsdaten": {12 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Business data request | GPKE part 4 | Electricity | Step 2 |
| NB | NB | Business data request | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | Business data request | GPKE part 4 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to GDA |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Business data request | NB → MSB | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Request: No reference recorded in the source. Neither the Prüfi table (reaktion_auf) nor the step sequence of the processes names the message that this response answers.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+AAV | dokumentennummer |
RFF+AAV quotes the preceding message via its BGM; the target is the dokumentennummer of the request. Which request is meant is not determined on this page (see above) — the target field is thus named, but not proven.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 533 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 5 transactions for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.