Check identifier 55669 — Response message/request for data of MeLo
Check identifier 55669 · EDIFACT message type UTILMD · format version 202604
Data structure
| Structure (BO4E) | Description | Format | 55669 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| datenqualitaet 00010 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| messlokationsId * 00020 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00030 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| ablesekartenempfaenger | — | object | May | — |
| anrede 00040 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| gewerbekennzeichnung 00050 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | Must | — |
| name1 00060 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00070 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00080 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00090 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00100 | House number and supplement | string | Must | — |
| landescode 00110 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00120 | City | string | Must | — |
| ortsteil 00130 | District | string | Must | — |
| postfach 00140 | PO box | string | Must | — |
| postleitzahl 00150 | Postal code | string | Must | — |
| strasse 00160 | Street | string | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00170 | zeitraumId | integer | X | — |
| messadresse | — | object | May | — |
| hausnummer 00180 | House number and supplement | string | Must | — |
| landescode 00190 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00200 | City | string | Must | — |
| ortsteil 00210 | District | string | Must | — |
| postfach 00220 | PO box | string | Must | — |
| postleitzahl 00230 | Postal code | string | Must | — |
| strasse 00240 | Street | string | Must | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00250 | Address supplement 1 | string | Must | — |
| zusatz2 00260 | Address supplement 2 | string | Must | — |
| zusatz3 00270 | Address supplement 3 | string | Must | — |
| zusatz4 00280 | Address supplement 4 | string | Must | — |
| zusatz5 00290 | Address supplement 5 | string | Must | — |
| MESSSTELLENBETRIEBSVERTRAG [ ] | — | object[] | May | — |
| datenqualitaet 00300 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00310 | zeitraumId | integer | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00320 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| name1 00330 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00340 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00350 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00360 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00370 | House number and supplement | string | Must | — |
| landescode 00380 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00390 | City | string | Must | — |
| ortsteil 00400 | District | string | Must | — |
| postfach 00410 | PO box | string | Must | — |
| postleitzahl 00420 | Postal code | string | Must | — |
| strasse 00430 | Street | string | Must | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00440 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| geschaeftspartnerrolle 00450 | Role held by the business partner (e.g. prospect, customer). | array | Must | — |
| name1 00460 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00470 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00480 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00490 | name4 | string | Must | — |
| VERWENDUNGSZEITRAUM [ ] | — | object[] | May | — |
| datenqualitaet 00500 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| verwendungAb 00510 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00520 | verwendungBis | string (date-time) | X | — |
| zeitraumId 00530 | zeitraumId | integer | Must | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 00540 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| datenqualitaet 00550 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| fernschaltung 00560 | Remote switching | Enum Fernschaltung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| gateway 00570 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| messwerterfassung 00580 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| tarifart 00590 | Specification regarding supported tariff types. | Enum Tarifart | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
SMART_METER | — | — | Must | — |
LEISTUNGSGEMESSEN | — | — | Must | — |
| zaehlerauspraegung 00600 | Specification regarding the direction of the meter. | Enum Zaehlerauspraegung | Must | — |
EINRICHTUNGSZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
| zaehlernummer 00610 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00620 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00630 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00640 | The number printed on the device, which is assigned by the MSB. | string | Should | [166] ∧ [215] |
| geraetetyp 00650 | List of possible billable device types | Enum Geraetetyp | Should | [166] ∧ [215] |
WECHSELSTROMZAEHLER | — | — | Should | — |
DREHSTROMZAEHLER | — | — | Should | — |
ZWEIRICHTUNGSZAEHLER | — | — | Should | — |
RLM_ZAEHLER | — | — | Should | — |
IMS_ZAEHLER | — | — | Should | — |
BALGENGASZAEHLER | — | — | Should | — |
MAXIMUMZAEHLER | — | — | Should | — |
MULTIPLEXANLAGE | — | — | Should | — |
PAUSCHALANLAGE | — | — | Should | — |
VERSTAERKERANLAGE | — | — | Should | — |
SUMMATIONSGERAET | — | — | Should | — |
IMPULSGEBER | — | — | Should | — |
EDL_21_ZAEHLERAUFSATZ | — | — | Should | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | Should | — |
MENGENUMWERTER | — | — | Should | — |
STROMWANDLER | — | — | Should | — |
SPANNUNGSWANDLER | — | — | Should | — |
DATENLOGGER | — | — | Should | — |
KOMMUNIKATIONSANSCHLUSS | — | — | Should | — |
MODEM | — | — | Should | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | Should | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | Should | — |
DREHKOLBENGASZAEHLER | — | — | Should | — |
TURBINENRADGASZAEHLER | — | — | Should | — |
ULTRASCHALLZAEHLER | — | — | Should | — |
WIRBELGASZAEHLER | — | — | Should | — |
MODERNE_MESSEINRICHTUNG | — | — | Should | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | Should | — |
STEUEREINRICHTUNG | — | — | Should | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | Should | — |
TARIFSCHALTGERAET | — | — | Should | — |
RUNDSTEUEREMPFAENGER | — | — | Should | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | Should | — |
MESSWANDLERSATZ_IMS_MME | — | — | Should | — |
KOMBIMESSWANDLER_IMS_MME | — | — | Should | — |
TARIFSCHALTGERAET_IMS_MME | — | — | Should | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | Should | — |
TEMPERATUR_KOMPENSATION | — | — | Should | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | Should | — |
SONSTIGES_GERAET | — | — | Should | — |
SMARTMETERGATEWAY | — | — | Should | — |
STEUERBOX | — | — | Should | — |
BLOCKSTROMWANDLER | — | — | Should | — |
KOMBIMESSWANDLER | — | — | Should | — |
MODEM_GSM | — | — | Should | — |
ETHERNET_KOM | — | — | Should | — |
PLC_COM | — | — | Should | — |
MODEM_FESTNETZ | — | — | Should | — |
DSL_KOM | — | — | Should | — |
LTE_KOM | — | — | Should | — |
DICHTEMENGENUMWERTER | — | — | Should | — |
TEMPERATURMENGENUMWERTER | — | — | Should | — |
ZUSTANDSMENGENUMWERTER | — | — | Should | — |
MESSDATENREGISTRIERGERAET | — | — | Should | — |
WANDLER | — | — | Should | — |
BEFESTIGUNGSEINRICHTUNG | — | — | Should | — |
| weitereGeraetenummern 00660 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 00670 | faktor | number (float) | Must | — |
| geraetemerkmal 00680 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00690 | zeitraumId | integer | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00700 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| konfiguration 00710 | Configuration (iMSys) of the meter register | string | X | — |
| nachkommastelle 00720 | nachkommastelle | integer | Must | — |
| obisKennzahl 00730 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| schwachlastfaehig 00740 | schwachlastfaehig | Enum Schwachlastfaehig | X | — |
SCHWACHLASTFAEHIG | — | — | X | — |
NICHT_SCHWACHLASTFAEHIG | — | — | X | — |
| vorkommastelle 00750 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00760 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00770 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00780 | Metering time period definition | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer 00790 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00800 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00810 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00820 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00830 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00840 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00850 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 00860 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00870 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00880 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00890 | Email address | string | Must | — |
| nachname 00900 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00910 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00920 | rufnummer | string | Must | — |
| antwortStatusZeitraum [ ] | — | object[] | May | — |
| code 00930 | code | string | X | — |
| liste 00940 | liste | string | X | — |
| zeitraumId 00950 | zeitraumId | integer | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00960 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00970 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55669 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | [705] |
1001 Z8800080 | Request for data clearing | — | X | [706] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document-/message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00130 | Document-/message sender or sender | — | X | — |
303900140 | MP-ID | — | X | — |
3055 900150 | GS1 | — | X | — |
3055 29300160 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00170 | Information contact | — | X | — |
341200180 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800190 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00200 | Electronic mail | — | X | [1P0..1] |
3155 FX00210 | Fax number | — | X | [1P0..1] |
3155 TE00220 | Telephone | — | X | [1P0..1] |
3155 AJ00230 | further telephone | — | X | [1P0..1] |
3155 AL00240 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00250 | Message recipient | — | X | — |
303900260 | MP-ID | — | X | — |
3055 900270 | GS1 | — | X | — |
3055 29300280 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400290 | Transaction | — | X | — |
740200300 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700310 | Transaction reason | — | X | — |
9013 ZX700320 | Change data of the MeLo | — | X | — |
| SG4.STS | — | — | Must | [301] ∧ [557] ∧ [2011] |
9015 E0100330 | Status of the response | — | X | — |
901300340 | Code of the check step | — | X | — |
1131 E_058300350 | EBD no. E_0583 | — | X | — |
901200360 | Time period ID from the change notification of the responsible party | — | X | [914] ∧ [937] ∧ [44] |
| SG5.LOC | — | — | Must | — |
3227 Z1700370 | Metering location | — | X | — |
322500380 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300390 | Check identifier | — | X | — |
1154 5566900400 | GPKE / Response message / Request for data of the MeLo from wMSB to MSB | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00410 | Transaction reference number | — | X | — |
115400420 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z4700430 | Data available in the system | — | X | [5P0..n] |
1153 Z4800440 | Expected data | — | X | [2P0..n] |
1153 Z5400450 | No data available in the system | — | X | [4P0..n] |
1153 Z5500460 | No data expected | — | X | [2P0..n] |
115600470 | Time period ID | — | X | [914] ∧ [937] [127] ⊻ [128] |
| SG6.DTM | — | — | Must | [131] ⊻ [134] ⊻ [135] |
2005 Z2500480 | Data used from | — | X | — |
238000490 | Date or time or time span, value | — | X | [UB1] |
2379 30300500 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | [472] ⊻ [473] |
2005 Z2600510 | Data used until | — | X | — |
238000520 | Date or time or time span, value | — | X | [UB1] |
2379 30300530 | CCYYMMDDHHMMZZZ | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG600540 | Expected data of the metering location | — | X | [2P0..n] |
1229 ZG700550 | Data of the metering location existing in the system | — | X | [3P0..n] |
105000560 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7037 E0400570 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0300580 | Extra-high voltage | — | X | — |
7111 E0400590 | High voltage | — | X | — |
7111 E0500600 | Medium voltage | — | X | — |
7111 E0600610 | Low voltage | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZA300620 | Expected metering device data | — | X | [2P0..n] |
1229 ZA400630 | Metering device data available in the system | — | X | [3P0..n] |
105000640 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1400650 | Smart meter gateway | — | X | — |
115400660 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1300670 | Meter type | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 AHZ00680 | analog household meter (three-phase current) | — | X | — |
7111 WSZ00690 | analog alternating current meter | — | X | — |
7111 LAZ00700 | Load curve meter | — | X | — |
7111 MAZ00710 | Maximum demand meter | — | X | — |
7111 MME00720 | modern metering device according to MsbG | — | X | — |
7111 EHZ00730 | electronic household meter | — | X | — |
7111 IVA00740 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0100750 | EDL40 | — | X | [136] |
7110 Z0200760 | EDL21 | — | X | [136] |
7110 Z0300770 | other EHZ | — | X | [136] |
7110 Z0400780 | Standard | — | X | [346] |
7110 Z0500790 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Should | [8] |
7111 Z3000800 | Device number | — | X | — |
711000810 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 ETZ00820 | Single tariff | — | X | — |
7111 ZTZ00830 | Two-tariff | — | X | — |
7111 NTZ00840 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 ERZ00850 | Single-direction meter | — | X | — |
7111 ZRZ00860 | Bidirectional meter | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5800870 | Remote switching of the metering device | — | X | — |
7110 Z0600880 | present | — | X | — |
7110 Z0700890 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2800900 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 BKE00910 | Plug-in technology (mounting and contacting device) | — | X | — |
7111 DPA00920 | 3-Three-point suspension | — | X | — |
7111 HUT00930 | DIN rail | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1200940 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR00950 | remotely readable meters | — | X | — |
7111 MMR00960 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZA500970 | Expected OBIS data of the metering device | — | X | [2P0..n] |
1229 ZA600980 | OBIS data of the metering device available in the system | — | X | [3P0..n] |
105000990 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | [665] |
1153 MG01000 | Device number of the meter | — | X | [204] |
1153 Z1401010 | Smart meter gateway | — | X | — |
115401020 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK01030 | Application reference number | — | X | — |
115401040 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501050 | Product identification | — | X | — |
714001060 | OBIS code of the metering device | — | X | [323] |
7143 SRW01070 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401080 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901090 | Annually | — | X | — |
7111 ZE801100 | Semi-annual | — | X | — |
7111 ZE901110 | Quarterly | — | X | — |
7111 ZB701120 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901130 | Code of the metering time period definition | — | X | — |
703701140 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3801150 | Code of the metering time period register | — | X | — |
703701160 | Code of the metering time period register | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1101170 | Product | — | X | — |
7037 Z3301180 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001190 | Digits before the decimal point | — | X | — |
711001200 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6301210 | Local identifier for control purposes | — | X | — |
703601220 | Designation of the register on the device | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1001230 | Low-load capability | — | X | — |
7037 Z5901240 | Not off-peak capable | — | X | — |
7037 Z6001250 | Low-load capable | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZB901260 | Expected instrument transformer data | — | X | [2P0..n] |
1229 ZC001270 | Instrument transformer data available in the system | — | X | [3P0..n] |
105001280 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | — |
1153 MG01290 | Device number of the meter | — | X | — |
115401300 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2501310 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 Z3001320 | Device number | — | X | — |
711001330 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW01340 | Current transformer set | — | X | — |
7111 MPW01350 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW01360 | Block current transformer | — | X | — |
7111 MUW01370 | Voltage transformer set | — | X | — |
711001380 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 ZB701390 | Expected communication device data | — | X | [2P0..n] |
1229 ZB801400 | Communication device data available in the system | — | X | [3P0..n] |
105001410 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | — |
1153 MG01420 | Device number of the meter | — | X | — |
115401430 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2601440 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001450 | Device number | — | X | — |
711001460 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM01470 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH01480 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC01490 | PLC comm. device | — | X | — |
7111 PST01500 | Landline comm. dev. TAE | — | X | — |
7111 DSL01510 | DSL comm. dev. | — | X | — |
7111 LTE01520 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZC101530 | Expected data of the technical control device | — | X | [2P0..n] |
1229 ZC201540 | Data of the technical control device available in the system | — | X | [3P0..n] |
105001550 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | — |
1153 MG01560 | Device number of the meter | — | X | — |
115401570 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2701580 | Technical control device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001590 | Device number | — | X | — |
711001600 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 RSU01610 | Ripple control receiver | — | X | — |
7111 TSU01620 | Tariff time switch | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZC301630 | Expected smart meter gateway | — | X | [2P0..n] |
1229 ZC401640 | Smart meter gateway available in the system | — | X | [3P0..n] |
105001650 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7037 Z7501660 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001670 | Device number | — | X | — |
711001680 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 ZH301690 | Expected data of the control box | — | X | — |
1229 ZH401700 | Data of the control box available in the system | — | X | — |
105001710 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | — |
1153 Z1401720 | Smart meter gateway | — | X | — |
115401730 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7601740 | Control box | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001750 | Device number | — | X | — |
711001760 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 Z3901770 | Expected customer of the MSB | — | X | [2P0..1] |
3035 Z4001780 | Customer of the MSB available in the system | — | X | [3P0..1] |
303601790 | Name | — | X | — |
3045 Z0101800 | Structure of person names | — | X | — |
3045 Z0201810 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601820 | Reference to time period ID | — | X | — |
115401830 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z4101840 | Expected correspondence address of the customer of the MSB | — | X | [2P0..1] |
3035 Z4201850 | Correspondence address of the customer of the MSB available in the system | — | X | [3P0..1] |
303601860 | Name | — | X | — |
3045 Z0101870 | Structure of person names | — | X | — |
3045 Z0201880 | Structure of the company name | — | X | — |
304201890 | Street and house number or PO box | — | X | — |
316401900 | City | — | X | — |
325101910 | Postal code | — | — | M [268] S [166] |
320701920 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601930 | Reference to time period ID | — | X | — |
115401940 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z4301950 | Expected metering location address | — | X | [2P0..1] |
3035 Z4401960 | Metering location address available in the system | — | X | [3P0..1] |
312401970 | Additional information for identification | — | — | S [336] |
304201980 | Street and house number or PO box | — | — | S [166] M [212] |
316401990 | City | — | X | — |
325102000 | Postal code | — | X | — |
320702010 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4602020 | Reference to time period ID | — | X | — |
115402030 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z4502040 | Expected name and address for the meter reading card | — | X | [2P0..1] |
3035 Z4602050 | Name and address for the meter reading card available in the system | — | X | [3P0..1] |
303602060 | Name | — | X | — |
3045 Z0102070 | Structure of person names | — | X | — |
3045 Z0202080 | Structure of the company name | — | X | — |
304202090 | Street and house number or PO box | — | X | — |
316402100 | City | — | X | — |
325102110 | Postal code | — | — | M [268] S [166] |
320702120 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4602130 | Reference to time period ID | — | X | — |
115402140 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| UNT | — | — | Must | — |
007402150 | Number of segments in a message | — | X | — |
006202160 | Message reference number | — | X | — |
Conditions of this table
The free text of the 48 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [8] | If required for data clearing |
| [22] | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| [44] | The time period ID from DE1156 of a matching SG6 RFF+Z49/Z53 (usage period of the data: "valid data", "no data") from the request message from SG6 RFF+TN DE1154 ((reference transaction number (from request message)) must be entered |
| [127] | The value resulting from the number of repetitions of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) must be entered. This means: the first SG6 RFF+Z48/Z55 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [128] | The value resulting from the number of repetitions of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) must be entered. This means: the first SG6 RFF+Z47/Z54 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [131] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage period of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message date) at 0:00, or a day earlier than that at 0:00 German time |
| [134] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with the next lower time period ID in DE1156 |
| [135] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) with the next lower time period ID in DE1156 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [166] | If present |
| [204] | The source provides no text for this brand. |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [301] | If BGM+E03 (change notification) present |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [336] | The source provides no text for this brand. |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [472] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) which is lower than in another SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) DE1156 (time period ID) |
| [473] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) which is lower than in another SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) DE1156 (time period ID) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [557] | Note: If the responsible party has sent more than eight usage periods, eight arbitrary usage periods are answered |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [705] | Note: If the action of a sequence diagram "Response message on change" is carried out |
| [706] | Note: If the action of a sequence diagram "Order placement of a change of master data..." is carried out with the aim of performing a data clearing |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [2011] | Segment group must be specified exactly once for each time period ID from DE1156 of the SG6 RFF+Z49 / Z53 (usage period of the data: "Valid data" / "No data") from the request message from SG6 RFF+TN DE1154 (reference transaction number (from request message)) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [5P0..n] | [315] If BGM+Z88 (data clearing) present [20 13 ] To be specified at least once , if no SG6 RFF+Z54 (Usage period of the data: no data present in the system) present |
| [2P0..n] | [301] If BGM+E03 (change notification) present [315] If BGM+Z88 (data clearing) present |
| [4P0..n] | [315] If BGM+Z88 (data clearing) present [20 14 ] To be specified at least once , if no SG6 RFF+Z47 (Usage period of the data: data present in the system) present |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [3P0..n] | [315] If BGM+Z88 (data clearing) present |
| [2P0..1] | [301] If BGM+E03 (change notification) present [315] If BGM+Z88 (data clearing) present |
| [3P0..1] | [315] If BGM+Z88 (data clearing) present |
Example message
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9904446000007:500+{{date}}:{{time}}+M07TZCKD'
UNH+UNHM02BVX4E+UTILMD:D:11A:UN:S2.1'
BGM+E03+BGMM0HNWDMO'
DTM+137:202506051200?+00:303'
NAD+MS+9904446000007::293'
NAD+MR+9904446000007::293'
IDE+24+123456'
STS+7++ZX7'
STS+E01++A01:E_0583::1'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55669'
RFF+TN:ABC123456'
UNT+12+UNHM02BVX4E'
UNZ+1+M07TZCKD'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"MESSLOKATION": [1 item
{4 fields
"transaktionsdaten": {13 fields
"absender": {5 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [1 item
{3 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
| LF | LF | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 8 |
| NB | NB | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
| NB | NB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 8 |
| MSB | MSB | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
| MSB | MSB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 8 |
| MSB | WMSB | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
| MSB | WMSB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 8 |
| ÜNB | ÜNB | Order placement for a master data change to the MSB (responsible) | GPKE part 4 | Electricity | Step 5 |
| ÜNB | ÜNB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 8 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response message/request data of the MeLo |
| AHB | UTILMD AHB electricity |
| Response to check identifier | 55663 |
| Decision tree | E_0583 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Master data change initiated by the MSB (responsible) | further MSB → MSB | Response message on change |
| GPKE part 4 | Order placement for master data change to MSB (responsible) | further MSB → MSB | Order placement of a change of master data from the further MSB to MSB |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response message. Basis: the title or the action of the Prüfi table begins with “response message”. A response message carries no status field and is not a response in the sense of a decision tree.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Editorial — not derived from a source
The period ID of this response comes from the request. Condition [44] requires in STS DE9012: »Es ist die Zeitraum-ID vom DE1156 aus einem passenden SG6 RFF+Z49/Z53 … einzutragen« (the period ID from DE1156 of a matching SG6 RFF+Z49/Z53 of the request). In the JSON it is in transaktionsdaten.antwortStatusZeitraum → zeitraumId (SG4.IDE+24.STS+E01). Its value is the zeitraumId of the request's usage period that the response refers to: stammdaten.VERWENDUNGSZEITRAUM → zeitraumId (SG4.IDE+24.SG6.RFF+[Z49|Z53]).
Source: UTILMD AHB electricity (Knowledge Collection ahb/202604/UTILMDS and ahb/202610/UTILMDS), condition [44] at SG4 STS DE9012; segment mapping of the zeitraumId fields in the check identifier specifications · As of: 2026-09-23 · Applies to format version: 202604, 202610 · To be reviewed by: 2027-04-01
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 290 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.