Check identifier 55073 — Transmission of the profile definitions
Check identifier 55073 · EDIFACT message type UTILMD · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55073 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z1800070 | Profile definition | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 15700120 | Validity, start date | — | X | — |
238000130 | Date or time or time span, value | — | X | — |
2379 61000140 | CCYYMM | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00150 | Document-/ message sender or sender | — | X | — |
303900160 | MP-ID | — | X | — |
3055 900170 | GS1 | — | X | — |
3055 29300180 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00190 | Message recipient | — | X | — |
303900200 | MP-ID | — | X | [280] |
3055 900210 | GS1 | — | X | — |
3055 29300220 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | [564] |
7495 Z0100230 | List | — | X | — |
740200240 | List number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z1300250 | Check identifier | — | X | — |
1154 5507300260 | MaBiS / Transmission of the profile definitions | — | X | — |
| SG4.IDE | — | — | Must | [504] ∧ [565] |
7495 2400270 | Transaction | — | X | — |
740200280 | Transaction number | — | X | — |
| SG4.FTX | — | — | Must | [52] Should [53] |
4451 Z0100290 | Profile description | — | X | — |
444000300 | Text for further description | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2100310 | Profile data | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0700320 | Profile type | — | X | — |
7037 Z3800330 | Commercial general | — | X | — |
7037 Z3900340 | Commercial weekdays 8 - 18 | — | X | — |
7037 Z4000350 | Commercial with strong to predominant consumption in the evening hours | — | X | — |
7037 Z4100360 | Commercial continuous | — | X | — |
7037 Z4200370 | Commercial shop/hairdresser | — | X | — |
7037 Z4300380 | Commercial bakery with bakehouse | — | X | — |
7037 Z4400390 | Commercial weekend operation | — | X | — |
7037 Z4500400 | Agricultural businesses, general | — | X | — |
7037 Z4600410 | Agricultural businesses with dairy farming/ part-time livestock breeding | — | X | — |
7037 Z4700420 | Agriculture without dairy cattle | — | X | — |
7037 Z4800430 | Household | — | X | — |
7037 Z4900440 | Band load | — | X | — |
7037 Z5000450 | interruptible consumption device | — | X | — |
7037 Z5100460 | Space heating storage | — | X | — |
7037 Z5200470 | Street lighting | — | X | — |
7037 Z5300480 | Photovoltaic market location | — | X | — |
7037 Z5400490 | Combined heat and power plant | — | X | — |
7037 Z5500500 | other consuming market location | — | X | — |
7037 Z5600510 | other generating market location | — | X | — |
7037 ZC600520 | E-mobility charging point in a public area | — | X | — |
7037 ZC700530 | E-mobility charging point of a household | — | X | — |
7037 ZC800540 | E-mobility charging point of a commercial business | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0200550 | Standard load profile | — | X | — |
7059 Z0400560 | Standard feed-in profile | — | X | — |
7037 E0100570 | synthetic method | — | X | — |
7037 Z1000580 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711100590 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0600600 | Normalization factor | — | X | — |
7037 Z3500610 | 1.000.000 kWh/a | — | X | — |
7037 Z3700620 | 1.000.000 kW | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2000630 | Balancing area | — | X | — |
703700640 | Balancing area | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0800650 | Profile set data | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 Z0100660 | Calculation of the daily mean temperature | — | X | — |
7143 Z0300670 | 24h average | — | X | — |
7143 Z0400680 | equivalent daily mean temperature provided by the provider | — | X | — |
7143 Z0500690 | Equivalent daily mean temperature | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z1100700 | Share A | — | X | — |
606000710 | Share A in % | — | X | [902] ∧ [930] |
| SG9.QTY | — | — | Must | — |
6063 Z1200720 | Share B | — | X | — |
606000730 | Share B in % | — | X | [902] ∧ [930] |
| SG9.QTY | — | — | Must | — |
6063 Z1300740 | Share C | — | X | — |
606000750 | Share C in % | — | X | [902] ∧ [930] |
| SG9.QTY | — | — | Must | — |
6063 Z1400760 | Share D | — | X | — |
606000770 | Share D in % | — | X | [902] ∧ [930] |
| SG9.QTY | — | — | Must | — |
6063 Z1500780 | Reference temperature | — | X | — |
606000790 | Temperature in °C | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0700800 | Profile type | — | X | — |
7037 Z3800810 | Commercial general | — | X | — |
7037 Z3900820 | Commercial weekdays 8 - 18 | — | X | — |
7037 Z4000830 | Commercial with strong to predominant consumption in the evening hours | — | X | — |
7037 Z4100840 | Commercial continuous | — | X | — |
7037 Z4200850 | Commercial shop/hairdresser | — | X | — |
7037 Z4300860 | Commercial bakery with bakehouse | — | X | — |
7037 Z4400870 | Commercial weekend operation | — | X | — |
7037 Z4500880 | Agricultural businesses, general | — | X | — |
7037 Z4600890 | Agricultural businesses with dairy farming/ part-time livestock breeding | — | X | — |
7037 Z4700900 | Agriculture without dairy cattle | — | X | — |
7037 Z4800910 | Household | — | X | — |
7037 Z4900920 | Band load | — | X | — |
7037 Z5000930 | interruptible consumption device | — | X | — |
7037 Z5100940 | Space heating storage | — | X | — |
7037 Z5200950 | Street lighting | — | X | — |
7037 Z5300960 | Photovoltaic market location | — | X | — |
7037 Z5400970 | Combined heat and power plant | — | X | — |
7037 Z5500980 | other consuming market location | — | X | — |
7037 Z5600990 | other generating market location | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1201000 | Profile set | — | X | — |
| SG10.CAV | — | — | Must | — |
711101010 | Code of the profile set | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0301020 | day-parameter-dependent load profile | — | X | — |
7059 Z0501030 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0101040 | synthetic method | — | X | — |
7037 Z1001050 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711101060 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0601070 | Normalization factor | — | X | — |
7037 Z3501080 | 1.000.000 kWh/a | — | X | — |
7037 Z3601090 | 300 kWh/K | — | X | — |
7037 Z3701100 | 1.000.000 kW | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1101110 | Limiting constant | — | X | — |
7037 Z6101120 | 0 | — | X | — |
7037 Z6201130 | 1 | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9901140 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA001150 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703701160 | ID of climate zone / temperature measuring point | — | X | — |
113101170 | Service provider | — | X | [58] |
3055 8901180 | Assigned by the trader (here grid operator) | — | X | — |
3055 29301190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2001200 | Balancing area | — | X | — |
703701210 | Balancing area | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z3801220 | Reference profile data | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0701230 | Profile type | — | X | — |
7037 Z5301240 | Photovoltaic market location | — | X | — |
7037 Z5601250 | other generating market location | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0501260 | day-parameter-dependent feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711101270 | Code of the reference profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0601280 | Normalization factor | — | X | — |
7037 Z3501290 | 1.000.000 kWh/a | — | X | — |
7037 Z3701300 | 1.000.000 kW | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2001310 | Balancing area | — | X | — |
703701320 | Balancing area | — | X | — |
| UNT | — | — | Must | — |
007401330 | Number of segments in a message | — | X | — |
006201340 | Message reference number | — | X | — |
Conditions of this table
The free text of the 11 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [52] | If SG10 CCI+Z07++Z55/Z56 (profile type: other consuming market location / other generating market location) is present |
| [53] | If further specifications beyond CCI+Z07 (profile type) are possible |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [280] | Only MP-ID from the electricity division |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [504] | Note: One transaction required per profile (including profile set where applicable) |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [902] | Format: Possible value: ≥ 0 |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Transmission of the list of profile definitions from the NB to LF or ÜNB | MaBiS | Electricity | Step 1 |
| NB | NB | Transmission of the list of profile definitions from the NB to LF or ÜNB | MaBiS | Electricity | Step 1 |
| NB | NB | Transmission of the list of profile definitions from the NB to MSB | MaBiS | Electricity | Step 1 |
| MSB | MSB | Transmission of the list of profile definitions from the NB to MSB | MaBiS | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Transmission of the profile definitions |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
This check identifier is used in 3 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the list of profile definitions from the NB to MSB | NB → MSB | Transmission of the list of profile definitions |
| MaBiS | Transmission of the list of profile definitions from the NB to LF or ÜNB | NB → LF | Transmission of the list of profile definitions |
| MaBiS | Transmission of the list of profile definitions from the NB to LF or ÜNB | NB → ÜNB | Transmission of the list of profile definitions |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 173 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.